著者
Seijirow GOYA Tomoki WADA Kazumi SHIMADA Daiki HIRAO Ryuji FUKUSHIMA Norio YAMAGISHI Miki SHIMIZU Ryou TANAKA
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
vol.79, no.2, pp.380-386, 2017 (Released:2017-02-28)
参考文献数
42
被引用文献数
2 2

The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.
著者
Seijirow GOYA Tomoki WADA Kazumi SHIMADA Akiko UEMURA Ryou TANAKA
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
vol.80, no.11, pp.1754-1757, 2018 (Released:2018-11-23)
参考文献数
18
被引用文献数
4

A 7-year-old Miniature Schnauzer presented with exercise intolerance and easy fatigability. Echocardiography revealed the presence of supravalvular pulmonary stenosis. The peak velocity through the stenosis was 6.4 m/sec, and the interventricular septum was flattened. Cutting balloon angioplasty was designed for the treatment of coronary artery stenosis, which was resistant to conventional balloon angioplasty. Accordingly, the dog underwent cutting balloon angioplasty and conventional balloon dilation. One month after treatment, it showed neither exercise intolerance nor easy fatigability. The ventricular septum flattening disappeared. Five months later, the dog showed an increase in activity. Two years later, the peak velocity through the stenosis decreased to 4.4 m/sec. Neither clinical symptoms nor restenosis was observed. Thus, supravalvular pulmonary stenosis was successfully treated using this combination method. The present case showed that combined cutting balloon and conventional balloon angioplasty is a useful and minimally invasive treatment for supravalvular pulmonary stenosis.
著者
Seijirow GOYA Tomoki WADA Kazumi SHIMADA Akiko UEMURA Ryou TANAKA
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.18-0060, (Released:2018-09-20)
被引用文献数
4

A 7-year-old Miniature Schnauzer presented with exercise intolerance and easy fatigability. Echocardiography revealed the presence of supravalvular pulmonary stenosis. The peak velocity through the stenosis was 6.4 m/sec, and the interventricular septum was flattened. Cutting balloon angioplasty was designed for the treatment of coronary artery stenosis, which was resistant to conventional balloon angioplasty. Accordingly, the dog underwent cutting balloon angioplasty and conventional balloon dilation. One month after treatment, it showed neither exercise intolerance nor easy fatigability. The ventricular septum flattening disappeared. Five months later, the dog showed an increase in activity. Two years later, the peak velocity through the stenosis decreased to 4.4 m/sec. Neither clinical symptoms nor restenosis was observed. Thus, supravalvular pulmonary stenosis was successfully treated using this combination method. The present case showed that combined cutting balloon and conventional balloon angioplasty is a useful and minimally invasive treatment for supravalvular pulmonary stenosis.
著者
Seijirow GOYA Tomoki WADA Kazumi SHIMADA Daiki HIRAO Ryuji FUKUSHIMA Norio YAMAGISHI Miki SHIMIZU Ryou TANAKA
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.16-0323, (Released:2016-12-16)
被引用文献数
2

The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.