著者
Akira Nishimura Nobuo Koizumi
出版者
ACOUSTICAL SOCIETY OF JAPAN
雑誌
Acoustical Science and Technology (ISSN:13463969)
巻号頁・発行日
vol.31, no.2, pp.172-180, 2010-03-01 (Released:2010-03-01)
参考文献数
15
被引用文献数
1 1

A method of sampling jitter measurement based on time-domain analytic signals is proposed. Computer simulations and actual measurements were performed to compare the proposed method with the conventional method, in which jitter is evaluated from the amplitudes of sideband spectra for observed signals in the frequency domain. The results show that the proposed method is effective in that it 1) provides high temporal resolution as a result of the direct derivation of the jitter waveform, 2) achieves higher accuracy in the measurement of jitter amplitude, and 3) can separate phase modulation that originate in sampling jitter from amplitude modulation that originate in digital-to-analog and analog-to-digital conversion processes. Suitable measurement conditions and measurements to separate the effects of jitter in a digital-to-analog converter and an analog-to-digital converter are described.
著者
Tetsuya KAKITA Maki YAMAGISHI Sugao OSHIRO Chisako OYAKAWA Takashi NAGAMINE Tsuyoshi KUDEKEN Hisako KYAN Nobuo KOIZUMI
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
vol.84, no.10, pp.1324-1327, 2022 (Released:2022-09-21)
参考文献数
13
被引用文献数
1

A 2-year-old male mongoose-scat-detection dog was diagnosed with leptospirosis by urine PCR. The patient developed acute renal failure, hepatic dysfunction, and disseminated intravascular coagulation. Treatment with antibiotics was administered, including ampicillin and doxycycline, and supportive care management was provided. Seroconversion against serogroup Hebdomadis was observed on day 8. The leptospiral gene flaB was detected only in urine collected on day 1, from which Leptospira interrogans ST329 was identified by multilocus sequence typing using seven housekeeping genes. L. interrogans serogroup Hebdomadis ST329 has been isolated from mongooses and humans in Okinawa, Japan. This patient received early treatment with antibiotics, which may have contributed to the early recovery of renal function and removal of L. interrogans from kidney tissue.
著者
西村 明 小泉 宣夫 ニシムラ アキラ コイズミ ノブオ Akira Nishimura Nobuo Koizumi
雑誌
東京情報大学研究論集
巻号頁・発行日
vol.7, no.2, pp.79-92, 2004-02-20

いくつかの種類のディジタルオーディオ機器におけるサンプリングジッター測定の結果を示した。解析信号を用いたジッター測定は、CD-Rメディアの製造メーカの違い、信号のビットパターン、ディジタル信号伝送系、DAC, ADCそしてプレーヤのクロック発振器など、複数の要因が、オーディオ機器の微細なジッター特性に影響を与えていることを示した。ジッター測定を通じて得られた最大のジッター成分振幅は、ジッター周波数2 Hz以上において、2nsを下回った。従来の周波数変動検知実験の結果と比較すると、この程度のジッターが音質に与える影響を聴取者が検知することは困難であると予想される。