著者
Christian-Hendrik Heeger Enida Rexha Sabrina Maack Laura Rottner Thomas Fink Shibu Mathew Tilman Maurer Christine Lemeš Andreas Rillig Peter Wohlmuth Bruno Reissmann Roland Richard Tilz Feifan Ouyang Karl-Heinz Kuck Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-1144, (Released:2020-04-18)
参考文献数
20
被引用文献数
17

Background:The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001).Conclusions:Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.
著者
Christian-Hendrik Heeger Enida Rexha Sabrina Maack Laura Rottner Thomas Fink Shibu Mathew Tilman Maurer Christine Lemeš Andreas Rillig Peter Wohlmuth Bruno Reissmann Roland Richard Tilz Feifan Ouyang Karl-Heinz Kuck Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.84, no.6, pp.902-910, 2020-05-25 (Released:2020-05-25)
参考文献数
20
被引用文献数
8 17

Background:The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001).Conclusions:Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.