著者
Christian-Hendrik Heeger Kentaro Hayashi Karl-Heinz Kuck Feifan Ouyang
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.80, no.5, pp.1073-1086, 2016-04-25 (Released:2016-04-25)
参考文献数
53
被引用文献数
21 34

Ventricular arrhythmias (VA), like premature ventricular contractions (PVC) and ventricular tachycardia (VT) in patients without structural heart disease (idiopathic VA), mainly arise from the right and left ventricular outflow tracts (RVOT/LVOT). The prognosis for OT VA is generally good in the majority of patients, but there is potential for developing dilated cardiomyopathies from the high burden of VA, as well as a certain risk for sudden cardiac death because of fast monomorphic VT or polymorphic VT triggered by short-coupling PVC. Radiofrequency catheter ablation (RFCA) has evolved into a widely accepted treatment strategy for patients suffering from VAs. A detailed knowledge of surface ECGs and complex cardiac anatomy, especially within the ventricular OTs, is essential for the understanding of cardiac OT-VAs and highly related to safe and successful RFCA procedures. This review article focuses on RFCA of idiopathic VA arising from the cardiac OT as well as adjacent regions and will illustrate recent insights and technical issues. (Circ J 2016; 80: 1073–1086)
著者
Christian-Hendrik Heeger Enida Rexha Sabrina Maack Laura Rottner Thomas Fink Shibu Mathew Tilman Maurer Christine Lemeš Andreas Rillig Peter Wohlmuth Bruno Reissmann Roland Richard Tilz Feifan Ouyang Karl-Heinz Kuck Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-1144, (Released:2020-04-18)
参考文献数
20
被引用文献数
17

Background:The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001).Conclusions:Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.
著者
Christian-Hendrik Heeger Amr Abdin Shibu Mathew Bruno Reissmann Kivanc Yalin Spyridon Liosis Thomas Fink Riccardo Proietti Charlotte Eitel Julia Vogler Christine Lemeš Tilman Maurer Andreas Rillig Roza Meyer-Saraei Tobias Graf Peter Wohlmuth Britta Goldmann Feifan Ouyang Karl-Heinz Kuck Andreas Metzner Roland Richard Tilz
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-0151, (Released:2019-06-28)
参考文献数
22
被引用文献数
20

Background:Second-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging results in the treatment of atrial fibrillation (AF). This study sought to assess data on the safety, efficacy and clinical success of CB2-based PVI in patients with heart failure (HF) and reduced ejection fraction (HFrEF).Methods and Results:CB2-based PVI was performed in 551 consecutive patients in 3 highly experienced EP centers. Patients with HF and LVEF ≤40% were included (HFrEF group, n=50/551, 9.1%). Data were compared with propensity score-matched patients without HF and preserved left ventricular EF (LVEF) (n=50, control group). The median LVEF was HFrEF: 37% (35, 40) and control: 55% (55, 55), P<0.0001. Major periprocedural complications were registered in 4/50 (8%, HFrEF group) and 3/50 (6%, control group), P=0.695. The 12-month freedom from AF recurrence was 73.1% (95% confidence interval (CI): 61–88, HFrEF group) and 72.6% (95% CI: 61–87, control group), P=0.25. NYHA class decreased from 2.4±0.8 (baseline) to 1.7±0.8 at 12-month follow-up (P<0.0001). LVEF improved from a median of 37% (35, 40) prior to ablation to a median of 55% (40, 55), P<0.0001.Conclusions:CB2-based PVI in patients with HFrEF appeared to be safe, was associated with comparable periprocedural complications and showed promising clinical success rates equal to those for patients with preserved LVEF. NYHA class and LVEF significantly improved at 12-month follow-up.
著者
Christian-Hendrik Heeger Enida Rexha Sabrina Maack Laura Rottner Thomas Fink Shibu Mathew Tilman Maurer Christine Lemeš Andreas Rillig Peter Wohlmuth Bruno Reissmann Roland Richard Tilz Feifan Ouyang Karl-Heinz Kuck Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.84, no.6, pp.902-910, 2020-05-25 (Released:2020-05-25)
参考文献数
20
被引用文献数
8 17

Background:The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001).Conclusions:Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.