著者
Fumiaki Kimura Futoshi Komine Kei Kubochi Shogo Yagawa
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.61, no.2, pp.327-334, 2019 (Released:2019-06-18)
参考文献数
25
被引用文献数
2

This study investigated bond strength of CAD/CAM-manufactured composite resin and ceramic veneers to a zirconia framework and analyzed the effect of treatments of veneer surfaces. A CAD/CAM resin-based (AVE) composite or lithium disilicate ceramic (IEC) block was used as the veneer material. AVE and IEC specimens were assigned to receive one of three surface treatments (n = 22): no surface treatment, acid-etching with 9.5% hydrofluoric acid gel, and airborne-particle abrasion with alumina particles. Zirconia disks and AVE or IEC specimens in each group were bonded with a resin-based luting agent, and shear bond strength of the specimens was measured at 0 and 20,000 thermocycles. Significant differences were assessed by the Steel-Dwass test for multiple comparisons and Mann-Whitney U-test (α = 0.05). As compared with other surface treatments, bond strengths were significantly higher at 0 and 20,000 thermocycles in the airborne-particle abraded AVE and acid-etched IEC specimens. Airborne-particle abrasion of the surface of AVE specimens increased bond strength between AVE veneers and zirconia frameworks, while hydrofluoric acid treatment enhanced bond strength between IEC veneers and zirconia frameworks.
著者
Futoshi KOMINE Shingo KAMIO Hiroki TAKATA Shogo YAGAWA Serina TAGUCHI Kohei TAGUCHI Akiko HASHIGUCHI Hideo MATSUMURA
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2017-057, (Released:2017-09-07)
参考文献数
41
被引用文献数
3

This study evaluated the effect of zirconia framework design on fracture load of implant-supported zirconia-based prostheses after thermal cycling and mechanical loading. Three different zirconia framework designs were investigated: uniform-thickness (UNI), anatomic (ANA), and supported anatomic (SUP) designs. Each framework was layered with feldspathic porcelain (ZAC group) or indirect composite material (ZIC group). The specimens then underwent fracture load testing after thermal cycling and cyclic loading. In the ZAC group, mean fracture load was significantly lower for UNI design specimens than for the other framework designs. In the ZIC group, there was no significant difference in mean fracture load between ANA design specimens and either UNI or SUP design specimens. To improve fracture resistance of implant-supported zirconia-based prostheses after artificial aging, uniformly thick layering material and appropriate lingual support with zirconia frameworks should be provided.