著者
Haruto HIRABA Hiroyasu KOIZUMI Hiroshi NOGAWA Kosuke TAKEHANA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2022-273, (Released:2023-04-28)
参考文献数
17

This study investigated the effect of 10-methacryloyloxydecyl dihydrogen phosphate (MDP) in methyl methacrylate (MMA) monomer on the adhesion of tri-n-butylborane (TBB)-initiated resins (MDP/MMA-TBB resins) to human enamel. Enamel surface conditions were either polished only or phosphatized surfaces. The 1.0, 1.7, and 2.0 mol% MDP/MMA-TBB resins, 4-methacryloxyethyl trimellitate anhydride (4-META)/MMA-TBB resin and MMA-TBB resin were prepared as luting materials. The shear bond strength was determined before and after thermocycles, and the results were compared using non-parametric statistical analyses (each, n=15). The MDP/MMA-TBB resins showed significantly better bond durability to enamel than other resins with or without etching. The 1.7 and 2.0 mol% MDP/MMA-TBB resins were suggested to be the optimum MDP concentrations from pre- and post-thermocycling results for the non-etched specimens. The TBB initiator resin including MDP was shown to be effective in bonding to human enamel, and this effect was enhanced in combination with phosphate treatment.
著者
Takeshi WADA Hiroyasu KOIZUMI Haruto HIRABA Takao HANAWA Hideo MATSUMURA Takayuki YONEYAMA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2022-184, (Released:2023-03-18)
参考文献数
36

This study evaluated the effect of luting system with acidic primers on the durability of bonds with Ti-15Mo-5Zr-3Al titanium alloy (Ti-15Mo-5Zr-3Al) and its component metals. Adherend metals were Ti-15Mo-5Zr-3Al, Ti, Mo, Zr, and Al. Four primers were evaluated as adhesion promoters: Alloy Primer (ALP), Estenia Opaque Primer (EOP), M. L. Primer (MLP), and Super Bond liquid (SBL). An acrylic resin was used as the luting material. Pre- and post-thermocycling shear bond strength was determined to evaluate the bonding durability, and the results were compared using non-parametric statistical analyses (n=11/group). The post-thermocycling bond strength in MPa (median) associated with ALP, EOP, MLP, and SBL were 18.8, 19.8, 4.1, and 0.8, respectively, for Ti-15Mo-5Zr-3Al. The results showed that two primers containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP) were effective for the durability of bonding of Ti-15Mo-5Zr-3Al to the resin. MDP enhanced the bonding durability of the resin bonded to either Ti, Zr, or Al.
著者
Haruto Hiraba Hiroyasu Koizumi Akihisa Kodaira Kosuke Takehana Takayuki Yoneyama Hideo Matsumura
出版者
Japan Prosthodontic Society
雑誌
Journal of Prosthodontic Research (ISSN:18831958)
巻号頁・発行日
pp.JPR_D_21_00308, (Released:2022-05-14)
参考文献数
32
被引用文献数
1

Purpose: To clarify the effect of a multi-purpose primer combining several functional monomers on two prosthodontic materials (cast titanium and a gold alloy) after airborne-particle abrasion.Methods: Disk-shaped adherends were prepared from cast titanium (CP Titanium JIS2) and a gold alloy (Casting Gold M.C. Type IV). A silane-containing two-liquid primer (M&C primer (MC)) and two silane-free single-liquid primers (Alloy Primer (AP) and V-Primer (VP)) were used as surface-treatment agents. The shear bond strengths were determined before and after thermocycling to evaluate the adhesive durability, and the results were compared using a non-parametric statistical analysis. The effect of airborne-particle abrasion with alumina on the titanium surface was analyzed by X-ray photoelectron spectroscopy (XPS).Results: There was no significant difference in bond strength between the MC and AP before and after thermocycling, whereas VP showed significantly lower values. XPS revealed that the titanium acquired hydrophilic properties after the airborne-particle abrasion.Conclusions: The novelty of this study is that it shows that the presence/absence of the silane had no effect on the bonding of cast titanium with an acrylic resin. The study also showed that the multi-purpose primer can be used without any problems with both cast titanium and gold alloy, in combination with airborne-particle abrasion with alumina.
著者
Kosuke TAKEHANA Hiroyasu KOIZUMI Haruto HIRABA Akihisa KODAIRA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-181, (Released:2021-12-28)
参考文献数
23

This study assessed the effect of a primer containing 10-methacryloyloxydecyl-(2-thiohydantoin-4-yl)propionate (MDTHP) on the bonding of noble metal alloys to an acrylic resin. Three noble metal alloys were selected as adherends, and V-Primer containing 6-(4-vinylbenzyl-n-propyl)amino-1,3,5-triazine-2,4-dithione was used as a comparative control. The disk specimens of each noble metal alloy were wet-ground and divided into three conditions: specimens primed with MDTHP primer or V-Primer, and specimens without priming. An acrylic resin was bonded to each specimen, and the specimens were performed the shear bond test. The MDTHP primer showed higher shear bond strength than the V-Primer for all specimens. X-ray photoelectron spectroscopic analysis showed that MDTHP was adsorbed on the Au-Pt-Pd alloy surface even after acetone cleaning. MDTHP binds not only with Cu but also with Au and Ag, promoting the bond strength of noble metal alloys. The effectiveness of MDTHP on dental noble metal alloys was suggested.
著者
Jin Kitani Futoshi Komine Kosuke Kusaba Daishi Nakase Keigo Ito Hideo Matsumura
出版者
Japan Prosthodontic Society
雑誌
Journal of Prosthodontic Research (ISSN:18831958)
巻号頁・発行日
pp.JPR_D_21_00055, (Released:2021-09-17)
参考文献数
20
被引用文献数
3

Purpose: This study evaluated the influence of firing procedures and layering thickness of porcelain on internal adaptation of maxillary anterior cantilever zirconia resin-bonded fixed dental prostheses (RBFDPs). Methods: The maxillary right central incisor on a model was prepared for a single-retainer zirconia RBFDP. A total of 36 frameworks of cantilever zirconia RBFDPs were classified into three groups (CB0.5, CB1.0, and CB2.0 groups) based on the thickness of the cut-back on the facial surface (0.5 mm, 1.0 mm, and 2.0 mm, respectively). Feldspathic porcelain was layered onto the facial surface of the zirconia RBFDP frameworks. Internal space widths between the abutment tooth and the framework were measured before and after porcelain firing by a replica technique. The internal space values before and after porcelain firings were compared using the paired t-test within the same group (α = 0.05). Differences in internal space values (distortion) between before and after porcelain firing were compared using one-way analysis of varianc e and Tukey multiple comparison tests. Results: For all framework designs, internal space values after porcelain firing were significantly higher than those before firing. Among all groups, the CB0.5 group showed the lowest internal distortion values for the whole measured area. The CB2.0 group showed higher distortion values than the CB1.0 group. Conclusions: Porcelain firing procedures negatively impacted the internal space in cantilever zirconia RBFDPs. In addition, the increased volume of layering porcelain had a negative effect on the internal distortion of ma xillary anterior cantilever zirconia RBFDPs.
著者
Keisuke MATSUSHIMA Kei KUBOCHI Futoshi KOMINE Fumiaki KIMURA Tatsuro KOBAYASHI Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-141, (Released:2021-09-04)
参考文献数
27
被引用文献数
1

The effects of mechanical retentive devices and various surface treatments on the shear bond strength between a veneering composite resin and zirconia was investigated. Zirconia disks were classified into three surface-treatment groups: airborne-particle abrasion, overglazing, and overglazing with white alumina particles of three different grain sizes (50, 70, and 105 μm) attached onto zirconia disks (ZR-50, ZR-70, and ZR-105, respectively). They were further divided into four groups (n=44): unprimed, Clearfil Porcelain Bond Activator (CA), Clearfil Photo Bond (CB), and CA+CB. An indirect composite resin was bonded to zirconia specimens. Shear bond strengths were measured. For the ZR-70 and ZR-105 groups, the CB and CA+CB specimens exhibited higher bond strengths than the other two specimens after thermocycling. The ZR-70 and ZR-105 groups achieved micromechanical interlocking, and priming with a phosphate monomer (MDP) yielded stable bond strengths between the composite resin and zirconia with alumina particles attached as retentive devices.
著者
Wataru MIKAMI Hiroyasu KOIZUMI Akihisa KODAIRA Haruto HIRABA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-137, (Released:2021-09-02)
参考文献数
26
被引用文献数
2

This study assessed the gloss and surface roughness of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites corroded with acidulated phosphate fluoride (APF) application. One ceramic block, ten CAD/CAM resin composites for premolars, and four CAD/CAM resin composites for molars were assessed. The surface topography of the materials before and after APF application was observed using an electron microscope. The results were analyzed by Wilcoxon signed-rank test and Dunnett’s many to one test (p<0.05). Gloss after APF application was significantly lower for all CAD/CAM resin composites except Artesano. Ra after APF application was significantly higher for all CAD/CAM resin composites except Artesano, Dentcraft HR Block, and Estelite P Block, and Sa was significantly higher for all CAD/CAM resin composites. Irregular surface topography was observed after APF application and the surface features differed among the materials. Therefore, APF application may be detrimental to the surface properties of CAD/CAM resin composites.
著者
Futoshi KOMINE Fumiaki KIMURA Kei KUBOCHI Ryoki TAKANO Daishi NAKASE Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2020-175, (Released:2021-01-15)
参考文献数
32
被引用文献数
1

This study investigated the influence of roughening procedures and application of primers on shear bond strengths of CAD/CAM composite resin material or ceramic material to zirconia frameworks. A CAD/CAM composite resin block (Katana Avencia Block; AVE) and lithium disilicate glass-ceramic block (IPS e.max CAD; IEC) were used as veneer materials. The veneers were divided into three surface treatment groups; HF, hydrofluoric acid etching; AB, airborne-particle abrasion; and CON, no surface treatment. Each veneer was primed with four agents: Clearfil Porcelain Bond Activator (ACT), Clearfil Photo Bond (CPB), Clearfil Photo Bond with Porcelain Bond Activator (CPB+ACT), and no priming (UP). The zirconia frameworks and AVE or IEC veneers were resin-bonded. In the AVE specimen, AB treatment showed significantly higher shear bond strength than the other treatments at 0 and 20,000 thermocycles, except for UP and CPB+ACT groups at 20,000 thermocycles. Airborne-particle abrasion is necessary for resin bonding to Avencia blocks.
著者
Mika Furuchi Yoshimasa Takeuchi Atsushi Kamimoto Hideo Matsumura Hideyuki Imai Hiroyasu Koizumi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.63, no.1, pp.119-120, 2021 (Released:2020-12-23)
参考文献数
8
被引用文献数
2

Cast titanium restoration for molars has high biocompatibility and is covered by the Japanese national health insurance. Titanium casting requires specific investment material and casting apparatus. A cast restoration for the mandibular left second molar was fabricated using titanium in this study. A wax pattern fabricated on a definitive cast was invested in calcium aluminate-bonded magnesia investment material. Titanium was cast using an argon gas pressure one-chamber casting apparatus. No defects were observed on the surface and the hole was clearly reproduced. A smooth surface on the restoration was obtained by polishing at low speed. Reproductivity and polishing properties of the titanium restoration fabricated in this study were comparable to those of conventional dental metal restorations.
著者
Yoshimasa Takeuchi Mika Furuchi Atsushi Kamimoto Kazuya Honda Hideo Matsumura Ryutaro Kobayashi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.62, no.3, pp.350-351, 2020 (Released:2020-06-23)
参考文献数
6
被引用文献数
34

The outbreak of novel coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread worldwide. Nasopharyngeal swabs are widely used in polymerase chain reaction (PCR) test to detect SARS-CoV-2. However, the collection of nasopharyngeal swabs has a series of drawbacks concerning exposure of healthcare staff, difficulty in collection, and discomfort of patients. Therefore, an alternative noninvasive sample for diagnostic of emerging viral diseases is required. The usefulness of saliva screening tests is compared to conventional swab tests in this report. The results suggest that saliva could be a reliable sample for detecting SARS-CoV-2.
著者
Yuta MORIYA Futoshi KOMINE Junichi HONDA Kosuke KUSABA Jin KITANI Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2019-216, (Released:2020-05-22)
参考文献数
29

To investigate the effect of luting agent type on fracture loads of implant-supported ceramic prostheses in premolar region. Ninety-nine implant-abutment complexes were divided into three different implant-supported prostheses: monolithic yttria-partially stabilized zirconia (Y-PSZ) restorations (MPZ specimens), porcelain layered on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations (PLZ specimens), and monolithic lithium disilicate ceramic restorations (MLD specimens). Implant-supported prostheses were luted with adhesive resin luting agent (RLA), glass ionomer cement (GIC), or zinc phosphate cement (ZPC). For MPZ and MLD specimens, fracture loads were significantly higher for RLA group than for GIC and ZPC groups. For PLZ specimens, fracture loads did not significantly differ in relation to luting agent. Fracture loads were significantly higher for MPZ specimens than for other test specimens, regardless of luting agent. Use of an adhesive resin luting agent is recommended for placement of premolar implant-supported monolithic Y-PSZ and lithium disilicate ceramic prostheses.
著者
Hideo Matsumura Katsunori Kojima Shigeru Mio Takashi Yamamoto Akihisa Kodaira Hiroyasu Koizumi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.19-0005, (Released:2020-05-15)
参考文献数
16
被引用文献数
5

The purpose of the current study was to synthesize a methacrylate monomer with a thiohydantoin structure. In a flask, (2-thiohydantoin-4-yl) propionic acid, 10-hyroxydecyl methacrylate, 4-dimethylaminopyridine, and tetrahydrofuran (THF) were placed in a nitrogen atmosphere. A THF solution of N,N’-dicyclohexylcarbodiimide was added and stirred at room temperature. Ethyl acetate and n-hexane were then added to the reaction mixture. The reacted slurry was purified by chromatography with silica gel and hexane-ethyl acetate gradient elution solvent. The structure of the compound was assigned with proton nuclear magnetic resonance spectrum analysis, infrared spectroscopy, and high-resolution mass spectral analysis. The colorless viscous liquid obtained in yield of 49% was characterized as 10-methacryloyloxydecyl-(2-thiohydantoin-4-yl)propionate (MDTHP) or 10-((3-(5-oxo-2-thioxysoimidazolidin-4-yl)propanoyl)oxy)decyl methacrylate (2-THPDM). The MDTHP was soluble to acetone, isopropanol, and methyl methacrylate up to 2.6% or more. This compound could be potentially applicable as a functional monomer for bonding metals and alloys.
著者
Shunsuke AKAHANE Hiroyasu KOIZUMI Akihisa KODAIRA Mitsuo NAKAMURA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2019-159, (Released:2020-05-12)
参考文献数
23

The purpose of this study is to investigate the combined effect of two-liquid silane-phosphate primer and single-liquid sodium sulfite primer on bonding between self-polymerizing resins and feldspathic ceramics, and to promote the polymerization behavior of self-polymerizing resins at the bonding interface. The silane-phosphate primer (Super-Bond PZ Primer; PZ) and the sodium sulfite primer (Teeth Primer; TP) were used as the surface treatment agents for bonding the feldspathic ceramics and the self-polymerizing resins (MMA-TBB resin and 4-META/MMA-TBB resin). Combined PZ and TP showed high shear bond strengths. The peak of the differential scanning calorimetry curve was shown to occur early through the addition of TP. These results indicated that additional TP promoted the conversion in the initial polymerization of resin, and the firmly bond was obtained at the interface. PZ+TP treatment can be regarded as an effective treatment for a temporary splint used in teeth restoration.
著者
Ryosuke FUSHIKI Futoshi KOMINE Fumiaki KIMURA Kosuke KUSABA Tomohide KONDO Yuta MORIYA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2018-253, (Released:2019-05-17)
参考文献数
34
被引用文献数
3

This study evaluated shear bond strengths of two gingiva-colored layering resin composites to zirconia frameworks coated with feldspathic porcelain. Airborne-particle abraded porcelain-coated zirconia disks were treated with one of the following primers: Clearfil Photo Bond, Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB+Activator), Estenia Opaque Primer, Porcelain Liner M Liquid B (PLB), or no primer. A light-polymerizing (CER) or a photo/heat-polymerizing gingiva-colored indirect resin composite (EST) was bonded to the porcelain-coated zirconia disks in each group (n=11). Shear bond strength was measured. For both CER and EST specimens, bond strengths in CPB+Act group were significantly higher than those in the other groups. In all priming groups, bond strength was significantly higher for EST specimens than for CER specimens. Combined application of a phosphate monomer and silane enhanced initial bond strength of light-polymerized and photo/heat-polymerized gingiva-colored layering resin composites to porcelain-coated zirconia ceramics.
著者
Nobutaka AKAZAWA Hiroyasu KOIZUMI Hiroshi NOGAWA Akihisa KODAIRA Michael F. BURROW Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2018-152, (Released:2019-05-09)
参考文献数
28
被引用文献数
8

The purpose of the current study was to evaluate the effect of etching with potassium hydrogen difluoride (KHF2) and ammonium hydrogen difluoride (NH4HF2) on the bond strength of a self-polymerizing methyl methacrylate resin (MMA-TBB) bonded to zirconia. Zirconia disks were prepared using the following surface treatment: no treatment, alumina blasting, and etching with KHF2 or NH4HF2. The specimens were bonded with the MMA-TBB. The shear bond (Ø=5 mm) strength was measured. The surface free energies of the specimens were determined by measuring contact angles. The KHF2 and NH4HF2 groups exhibited higher shear bond strength and surface free energy than did the alumina blasting and no treatment groups. Compared with alumina blasting, etching with KHF2 and NH4HF2 exhibited superior bonding ability of mechanical retention to zirconia.
著者
Hideyuki Imai Hiroyasu Koizumi Akihisa Kodaira Kentaro Okamura Shunsuke Akahane Hideo Matsumura
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.61, no.1, pp.178-183, 2019 (Released:2019-03-28)
参考文献数
16
被引用文献数
1

This study evaluated the light intensity of light-emitting diode (LED) units and the effects of five laboratory polymerization units on hardness and flexural strength. Two indirect composite materials (Cesead N and Solidex Hardura) were polymerized with five units (α-Light II, Hyper LII, LED Cure Master, Twinkle LED, and α-Light V). The light intensity of the devices was measured with a spectroradiometer. After light exposure, Knoop hardness number, flexural strength, and elastic modulus were determined. Evaluation of light intensity, using a wavelength range of 400 to 500 nm, revealed that the α-Light V and Hyper LII units had the highest light intensity. For the top surface of the two composites, the Knoop hardness number was significantly higher for the α-Light V and Hyper LII. For the two composite materials, flexural strength did not differ among the five polymerizing units. The present results indicate that the Cesead N and Solidex Hardura composites can be adequately polymerized with laboratory LED units.
著者
Serina Taguchi Futoshi Komine Kei Kubochi Ryosuke Fushiki Fumiaki Kimura Hideo Matsumura
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.17-0383, (Released:2018-08-25)
参考文献数
35
被引用文献数
8

This study examined the effect of silane and phosphate functional monomer on bond strengths between a resin-based luting agent joined to a lithium disilicate ceramic (IPS e.max) and silica (quartz) materials. The e.max and quartz specimens were assigned to 6 groups with different priming/bonding agents, namely, Clearfil Porcelain Bond Activator, Clearfil Photo Bond, Clearfil Photo Bond Universal with Clearfil Porcelain Bond Activator, Clearfil Photo Bond Catalyst with Clearfil Porcelain Bond Activator, Clearfil Photo Bond with Clearfil Porcelain Bond Activator, and unprimed. The corresponding specimens were bonded by using a resin-based luting agent (Panavia V5). Shear bond strengths were determined before and after 5,000 thermocycles. For both the e.max and quartz specimens, the Clearfil Photo Bond Universal with Clearfil Porcelain Bond Activator group had the highest pre- and post-thermocycling bond strength values. Combined use of silane in the acidic environment of a phosphate functional monomer and initiators enhances bond strength of a resin-based luting agent to e.max ceramic and quartz materials.
著者
Hiroyasu Koizumi Takaya Ishii Tomoyo Okazaki Masahiro Kaketani Hideo Matsumura Takayuki Yoneyama
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.60, no.2, pp.285-292, 2018 (Released:2018-06-20)
参考文献数
38
被引用文献数
20

The castability, mechanical properties, and fracture characteristics of Ti-15Mo-5Zr-3Al alloy were compared with those of Ti-6Al-7Nb alloy and pure titanium (CP Ti) for application of this β-type titanium alloy in cast dental prostheses. Cast specimens were prepared with a centrifugal casting machine. A tensile test was performed according to ISO standard 22674. The castability index for Ti-15Mo-5Zr-3Al was lower than those for Ti-6Al-7Nb and CP Ti. The tensile strength of Ti-15Mo-5Zr-3Al was 852 MPa, which was lower than that of Ti-6Al-7Nb and higher than that of CP Ti. The proof strength of Ti-15Mo-5Zr-3Al was 799 MPa, which was comparable to that of Ti-6Al-7Nb and higher than that of CP Ti. The elastic modulus of Ti-15Mo-5Zr-3Al was 81.0 GPa, which was lower than the values for Ti-6Al-7Nb and CP Ti. Elongation of Ti-15Mo-5Zr-3Al was 5.1%, which was comparable to that of Ti-6Al-7Nb and less than that of CP Ti. The shape of the fractured segment was narrower for Ti-15Mo-5Zr-3Al than for Ti-6Al-7Nb and CP Ti. The deformation characteristics of Ti-15Mo-5Zr-3Al may result in decreased stress relative to increased strain during plastic deformation in the stress-strain diagram. In conclusion, Ti-15Mo-5Zr-3Al alloy has a low elastic modulus and exhibits limited ductile plastic deformation in cast dental prostheses.
著者
Yoshimasa Takeuchi Hiroyasu Koizumi Mika Furuchi Yohei Sato Chikahiro Ohkubo Hideo Matsumura
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.60, no.1, pp.1-7, 2018 (Released:2018-03-24)
参考文献数
32
被引用文献数
49

Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved substantially. This review discusses the accuracy of digital impression systems for fabrication of dental restorations and fixed dental prostheses. A literature search in PubMed was performed for the period from July 2010 through June 2017. The search keywords were Cerec, digital impression, direct digitalization, indirect digitalization, and intraoral scanner. Only relevant studies are summarized and discussed in this review. In general, the latest systems have considerably reduced the time required for impression making, and the accuracy and marginal fit of digital impression systems have recently improved. Restorations and fixed dental prostheses fabricated with currently available digital impression systems and intraoral scanners exhibit clinically acceptable ranges of marginal gap in both direct and indirect procedures.
著者
Tomoyo OKAZAKI Hiroyasu KOIZUMI Hiroshi NOGAWA Akihisa KODAIRA Tomotaro NIHEI Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2017-183, (Released:2018-01-26)
参考文献数
33
被引用文献数
1

This study aimed to investigate how different compositions of experimental silane-based primers in a methyl methacrylate solution containing 3-(trimethoxysilyl)propyl methacrylate (3-TMSPMA) or 3-(4-methacryloyloxyphenyl)propyl trimethoxysilane (3-MPPTS) might act as silicon dioxide bonding agents. With or without post-silanization heat treatment, primer-treated quartz discs were bonded using the MMA-TBB resin and their bond strengths were evaluated. The disks were primed with one of the following materials: 1 mol% 3-TMSPMA, 2 mol% 3-TMSPMA, 1 mol% 3-MPPTS, and 2 mol% 3-MPPTS. Shear bond strength was determined both before and after thermocycling. Statistical analyses were performed with non-parametric procedure (Kruskal-Wallis, Mann-Whitney U, and Steel-Dwass tests). Both primers were effective with heat treatment to enhance bonding between quartz and the MMA-TBB, and the bonding durability of the 1 and 2 mol% 3-MPPTS (16.8 and 24.9 MPa) with heat groups was significantly higher than in the 1 and 2 mol% 3-TMSPMA (5.4 and 9.8 MPa) with heat groups.