著者
Christian-H. Heeger Huong-Lan Phan Roza Meyer-Saraei Thomas Fink Vanessa Sciacca Spyridon Liosis Ben Brüggemann Niels Große Bezhad Fahimi Makoto Sano Karl-Heinz Kuck Feifan Ouyang Julia Vogler Charlotte Eitel Roland Richard Tilz
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-0766, (Released:2019-11-09)
参考文献数
29
被引用文献数
22

Background:Radiofrequency (RF)-based pulmonary vein isolation (PVI) results in a favorable clinical outcome, although its complexity demands a long learning curve. Balloon-based systems have been developed to possibly solve these limitations. The 2nd-generation laser balloon (LB2) offers optimized features for improved tissue contact and visibility. We determined the safety, efficacy and learning curve of the LB2 for PVI.Methods and Results:A total of 45 consecutive patients (89% persistent AF) were prospectively enrolled and divided into 3 groups (T1, T2, T3) of n=15 patients per group. All patients underwent PVI by 2 operators using the LB2. The operators were experienced in RF and cryothermal procedures, but not in laser ablations. A total of 174/177 PVs (98%) were successfully isolated. The median procedure time significantly declined from 132 (114, 158) to 119 (102, 127) and 91 (86, 105) min in T1–3, respectively (P=0.0009). Similarly, the median fluoroscopy time significantly decreased from T1 to T3 (22 (17, 27) vs. 21 (16, 24) vs. 13 (10, 17) min, respectively, P=0.045). Adverse events occurred in 6.7%, with a trend towards a lower complication rate with increasing experience.Conclusions:The LB2 was safe and effective for PVI, even for operators without any previous experience in laser balloon-based PVI. Procedure time, left atrial dwelling time and fluoroscopy time decreased after a learning curve of 15 cases.
著者
Christian-Hendrik Heeger Amr Abdin Shibu Mathew Bruno Reissmann Kivanc Yalin Spyridon Liosis Thomas Fink Riccardo Proietti Charlotte Eitel Julia Vogler Christine Lemeš Tilman Maurer Andreas Rillig Roza Meyer-Saraei Tobias Graf Peter Wohlmuth Britta Goldmann Feifan Ouyang Karl-Heinz Kuck Andreas Metzner Roland Richard Tilz
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-0151, (Released:2019-06-28)
参考文献数
22
被引用文献数
20

Background:Second-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging results in the treatment of atrial fibrillation (AF). This study sought to assess data on the safety, efficacy and clinical success of CB2-based PVI in patients with heart failure (HF) and reduced ejection fraction (HFrEF).Methods and Results:CB2-based PVI was performed in 551 consecutive patients in 3 highly experienced EP centers. Patients with HF and LVEF ≤40% were included (HFrEF group, n=50/551, 9.1%). Data were compared with propensity score-matched patients without HF and preserved left ventricular EF (LVEF) (n=50, control group). The median LVEF was HFrEF: 37% (35, 40) and control: 55% (55, 55), P<0.0001. Major periprocedural complications were registered in 4/50 (8%, HFrEF group) and 3/50 (6%, control group), P=0.695. The 12-month freedom from AF recurrence was 73.1% (95% confidence interval (CI): 61–88, HFrEF group) and 72.6% (95% CI: 61–87, control group), P=0.25. NYHA class decreased from 2.4±0.8 (baseline) to 1.7±0.8 at 12-month follow-up (P<0.0001). LVEF improved from a median of 37% (35, 40) prior to ablation to a median of 55% (40, 55), P<0.0001.Conclusions:CB2-based PVI in patients with HFrEF appeared to be safe, was associated with comparable periprocedural complications and showed promising clinical success rates equal to those for patients with preserved LVEF. NYHA class and LVEF significantly improved at 12-month follow-up.