Purpose: The aim of this study was to investigate the stability of orthodontic anchor screws (OASs) in the mid-palatal area according to pre-drilling diameter.Methods: The success rate of 161 OASs (83 patients, φ2.0 mm, 6.0 mm in length) placed in a corresponding area to the mesial and distal borders of the first molar (mesial zone and distal zone) was assessed according to placement location and pre-drilling diameter (1.2 and 1.5 mm). Placement torque values from 73 OASs with a pre-drilling diameter of 1.2 mm were compared between success and failure groups.Results: The success rates of OASs pre-drilled with φ1.2 and 1.5 mm were 94.5% and 83.0%, respectively (P < 0.05); corresponding rates in the mesial zone were 100.0% and 77.3% (P < 0.005), and those in the distal zone were 89.2% and 88.6%, respectively. Placement torques of OASs predrilled with φ1.2 mm in the success and failure groups were 25.9 and 19.2 N·cm, respectively (P < 0.05).Conclusion: A smaller pre-drilling diameter was associated with a higher success rate of OASs in the mid-palatal area, especially in the mesial zone. When pre-drilling diameter of 1.2 mm was used for φ2.0 mm OAS, greater placement torque was indicative of greater OAS stability.
著者
Atsuko Hotta Yasuki Uchida Yasuhiro Namura Mizuki Inaba Mitsuru Motoyoshi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.62, no.3, pp.318-321, 2020 (Released:2020-06-23)
参考文献数
30

This study used finite element (FE) analysis to investigate the stability of miniscrews (screws) placed at the median palate. FE models with variable suture maturity and screw-suture distances were used to examine the relationship with screw stability. Four groups were classified by extent of maturation of the midpalatal suture (0%, 60%, 75%, and 100%). The placement position was set at the center of the suture (0.0 mm), or 0.5, 1.0, and 1.5 mm to the side of the suture, and von Mises stress values in bone and screw displacement were compared among models. The stress value for the unsutured model, in which the screw was placed at the center of the suture, was greater than 30 MPa. Stress values for models in which screws were placed to the side (0.5-1.5 mm) were less than 28 MPa. Maximum screw displacement was greater in the 0.0-mm incomplete suture model than at other placement positions. Because bone conditions vary among patients, placement position and suture maturation should be examined on cone beam-computed tomography images, to ensure screw stability.
著者
Yasuhiro Namura Toshiki Takamizawa Yasuki Uchida Mizuki Inaba Daichi Noma Tomoko Takemoto Masashi Miyazaki Mitsuru Motoyoshi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.62, no.1, pp.48-51, 2020 (Released:2020-01-29)
参考文献数
20
被引用文献数
8

Although there have been improvements in bracket systems precoated with adhesive, removal of adhesive remnants continues to be problematic. This study compared the hardness and maintainability of precoated adhesive with other commercial adhesives. Knoop hardness values were measured after light- or chemical-induced initial curing, immersion in distilled water at 37°C for 24 h and 1,000 and 10,000 thermal cycles after 24 h. Additionally, the forces required to move brackets by 0.5 mm were measured during bracket positioning, and brackets bonded to bovine enamel were examined by field-emission scanning electron microscopy. The Knoop hardness values of the precoated adhesives were lower than those of commercial resin composite adhesives, and hardness was dependent on the amount of filler in the resin matrix. The ability to maintain the device position may depend on the resin matrix composition. Precoated adhesives with less filler and more matrix material are light curable, and remnant resin may be easily removed.
著者
Yasuhiro NAMURA Yasuki UCHIDA Ryoichi SATO Noriyoshi SHIMIZU Mitsuru MOTOYOSHI Yusuke TSUTSUMI Takao HANAWA Takayuki YONEYAMA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2019-023, (Released:2019-12-19)
参考文献数
21

Chemical transitions after atmospheric pressure plasma irradiation were investigated by evaluating intermolecular attractions and atomic and molecular reactions. Gold, titanium and stainless-steel alloy samples were ground with #800 grit SiC waterproof paper and nitrogen gas atmospheric plasma irradiation was conducted. The surface free energies of the treated alloys were calculated and compared statistically. X-ray photoelectron spectroscopy analysis was performed.The surface free energies of all metal surfaces treated by plasma irradiation were 1.5-times higher than those of the untreated metals. The energy of the hydrogen bonding component increased, and all alloy surfaces were coated with metal oxide after only a short period of plasma irradiation. The surfaces oxidized by plasma exhibited a high active energy, mainly due to an increase in the hydrogen bonding component. Reactions with oxygen in the air were promoted on the clean surfaces with exposed reactive elements.
著者
Michiko Ichinohe Mitsuru Motoyoshi Mizuki Inaba Yasuki Uchida Mari Kaneko Reiko Matsuike Noriyoshi Shimizu
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.17-0377, (Released:2018-10-26)
参考文献数
35
被引用文献数
19

This study investigated the stability of mini-screws placed in the median palate. The study included 25 patients (7 males, 18 females; mean age, 23.4 ± 5.6 years; age range, 15.0-34.5 years) who had mini-screws placed during orthodontic treatment at Nihon University School of Dentistry Dental Hospital. Mini-screws (diameter, 2.0 mm; length, 9.0 mm) were placed in the median palatal region; the first screw was inserted mesiodistally at the distal contact of the maxillary first molar, and the second screw was placed 6-9 mm mesial to the first screw. Immediately after placement, the placement sites were carefully examined with cone-beam computed tomography and a Periotest device. Screw stability was not related to perforation of the nasal cavity, patient age, or patient sex. The success rate was significantly higher in patients with screw-suture distances of 1.5-2.7 mm than in those with distances of 0-1.4 mm. Moreover, mini-screws could be stabilized when palatal cortical bone thickness was ≥1.5 mm. The success rate was significantly higher in the group with insertion depths of ≥4.5 mm. These results indicate that primary stability of mini-screws requires sufficient cortical bone thickness, insertion depth, and screw-suture distance.
著者
Wakako Miyama Yasuki Uchida Mitsuru Motoyoshi Keiko Motozawa Moeko Kato Noriyoshi Shimizu
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.60, no.1, pp.147-153, 2018 (Released:2018-03-24)
参考文献数
28
被引用文献数
3

This study examined the relationship of vertical and horizontal changes in the alveolar bone crest with upper incisor movement after orthodontic treatment. Tooth movement was measured on lateral cephalograms. Vertical and horizontal changes in the median alveolar crest and distance from the cementoenamel junction and anterior nasal spine to the alveolar crest were measured with cone-beam computed tomography. The incisal edge moved distally, and the cervical point intruded significantly and moved distally. The median alveolar crest decreased by 3.80 ± 2.05 mm. The distance from the labial cementoenamel increased significantly, by 0.35 ± 0.38 mm. The vertical distance from the anterior nasal spine decreased significantly, and the alveolar crest moved distally. Vertical tooth movement was positively associated with change in the distance from the labial cementoenamel junction and inversely associated with vertical change in the distance from the anterior nasal spine on the labial and palatal sides. Lingual tooth movement was positively and negatively correlated with horizontal changes in the labial and palatal alveolar crest and vertical change in the palatal alveolar crest. The lingual movement of incisors was related to labial bone resorption. Greater lingual and extrusive movement of incisors led to a greater decrease in the alveolar bone crest.
著者
Yasuki Uchida Mitsuru Motoyoshi Yasuhiro Namura Noriyoshi Shimizu
出版者
日本大学歯学部
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.59, no.2, pp.257-262, 2017 (Released:2017-06-22)
参考文献数
29
被引用文献数
5

This study investigated guidelines for placement of monocortical screws in the mandible, particularly the mandibular canal. In this study of 35 patients, we used cone-beam computed tomography to determine the distance from the alveolar crest to the superior border of the mandibular canal (DMC) and the shortest distance from the buccal and lingual cortex to the mandibular canal (attaining distance) in the areas between premolars (premolar area), between the second premolar and first molar (middle area), and between the first and second molars (molar area). The DMC values for these areas were 16.55, 18.94, and 16.58 mm, respectively, and were similar in adults and adolescents. When the attaining distance was 8 mm, the heights on the buccal and lingual sides of the areas were 9 and 16.6 mm, 13.7 and 14.7 mm, and 15.3 and 12 mm, respectively. Risk of proximity to the mandibular canal should be considered at above heights or greater when an orthodontic anchorage device (OAD) 8 mm in length is placed. Careful attention is needed for placements on lingual side in adolescents. By reducing the OAD length to 6 mm, placement safety increases in all areas except the premolar area, especially on the buccal side.