著者
Masato Okada Koichi Inoue Koji Tanaka Yuichi Ninomiya Yuko Hirao Takafumi Oka Nobuaki Tanaka Hiroyuki Inoue Ryo Nakamaru Yasushi Koyama Atsunori Okamura Katsuomi Iwakura Yasushi Sakata Kenshi Fujii
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.82, no.4, pp.956-964, 2018-03-23 (Released:2018-03-23)
参考文献数
14
被引用文献数
14 17

Background:This study evaluated the safety and efficacy of venous figure-of-eight (FoE) suture to achieve femoral venous hemostasis after radiofrequency (RF) catheter ablation (CA) for atrial fibrillation (AF).Methods and Results:We retrospectively examined 517 consecutive patients undergoing RFCA for AF. The control group (n=247) underwent manual compression for femoral venous hemostasis after sheath removal with 6 h of bed rest. The FoE group (n=270) underwent FoE suture technique with 4 h of bed rest. All patients achieved successful hemostasis within 24 h after CA. Although the incidence of hematoma was similar between the groups, the incidence of rebleeding was lower in the FoE group than in the control group (FoE vs. control, 3.7% vs. 18.6%, P<0.001). The post-procedural use of analgesic and/or anti-emetic agents was less frequent in the FoE group (19.3% vs. 32.0%, P<0.001). On multiple logistic regression analysis after adjustment for age and sex, the use of a vitamin K antagonist (OR, 2.42; 95% CI: 1.18–4.99, P=0.02) and the FoE suture technique (OR, 0.17; 95% CI: 0.08–0.35, P<0.001) were independent predictors of rebleeding after CA.Conclusions:FoE suture technique effectively achieved femoral venous hemostasis after RFCA for AF. It reduced the risk of rebleeding, shortened bed rest duration, and relieved patient discomfort.
著者
Toru Miyoshi Kunihisa Kohno Hirohiko Asonuma Satoru Sakuragi Makoto Nakahama Yusuke Kawai Tadahisa Uesugi Takefumi Oka Mitsuru Munemasa Natsuki Takahashi Naoki Mukohara Seiji Habara Yasushi Koyama Kazufumi Nakamura Hiroshi Ito on behalf of the PEACH Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.82, no.2, pp.532-540, 2018-01-25 (Released:2018-01-25)
参考文献数
39
被引用文献数
13

Background:The effect of lipid-lowering agents on progression of coronary artery calcification (CAC) remains unclear. We evaluated the effects of pitavastatin 2 mg/day (PIT2), pitavastatin 4 mg/day (PIT4), and PIT2 combined with eicosapentaenoic acid (PIT2+EPA) on CAC progression.Methods and Results:This prospective multicenter study in Japan included patients with an Agatston score of 1–999, hypercholesterolemia, and no evidence of cardiovascular disease. Patients were allocated into PIT2, PIT4, or PIT2+EPA groups. The primary outcome was the annual percent change in Agatston score in all patients. In total, 156 patients who had multi-detector row computed tomography without any artifacts were included in the primary analysis. Pitavastatin did not significantly reduce the annual progression rate of the Agatston score (40%; 95% CI: 19–61%). The annual progression rate of Agatston score in the PIT2 group was not significantly different from that in the PIT4 group (34% vs. 42%, respectively; P=0.88) or the PIT2+EPA group (34% vs. 44%, respectively; P=0.80). On post-hoc analysis the baseline ratio of low- to high-density lipoprotein cholesterol was a significant predictor of non-progression of Agatston score by pitavastatin (OR, 2.17; 95% CI: 1.10–44.12; P=0.02).Conclusions:Pitavastatin does not attenuate progression of CAC. Intensive pitavastatin treatment and standard treatment with EPA does not reduce progression of CAC compared with standard treatment.
著者
Nobuaki Tanaka Koji Tanaka Yuichi Ninomiya Yuko Hirao Takafumi Oka Masato Okada Hiroyuki Inoue Ryo Nakamaru Kohtaro Takayasu Ryo Kitagaki Yasushi Koyama Atsunori Okamura Katsuomi Iwakura Yasushi Sakata Kenshi Fujii Koichi Inoue
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-18-1035, (Released:2019-02-06)
参考文献数
25
被引用文献数
4

Background: Automated ablation lesion annotation with optimal settings for parameters including contact force (CF) and catheter stability may be effective for achieving durable pulmonary vein isolation. Methods and Results: We retrospectively examined 131 consecutive patients who underwent initial catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) by automatic annotation system (VISITAG module)-guided radiofrequency CA (RFCA) (n=61) and 2nd-generation cryoballoon ablation (CBA) (n=70) in terms of safety and long-term efficacy. The automatic annotation criteria for the RFCA group were as follows: catheter stability range of motion ≤1.5 mm, duration ≥5 s, and CF ≥5 g. We ablated for >20 s with a force-time integral >150 gs at each site, before moving to the next site. Each interlesion distance was <6 mm. Procedural complications were more frequent in the CBA group (1.6% vs. 10.0%, P=0.034). Across a median follow-up of 2.98 years, 88.5% and 70.0% of patients in the RFCA and CBA groups, respectively, were free from recurrence (log-rank test, P=0.0039). There was also a significant difference in favor of RFCA with respect to repeat ablations (3.3% vs. 24.3%, log-rank test, P=0.0003). Conclusions: RF ablation guided by an automated algorithm that includes CF and catheter stability parameters showed better long-term outcomes than CBA in the treatment of patients with PAF without increasing complications.
著者
Nobuaki Tanaka Koichi Inoue Koji Tanaka Yuko Toyoshima Takafumi Oka Masato Okada Hiroyuki Inoue Ryo Nakamaru Yasushi Koyama Atsunori Okamura Katsuomi Iwakura Yasushi Sakata Kenshi Fujii
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.81, no.11, pp.1596-1602, 2017-10-25 (Released:2017-10-25)
参考文献数
21
被引用文献数
2 24

Background:Durable pulmonary vein isolation (PVI) is critical in reducing recurrence after radiofrequency catheter ablation for atrial fibrillation (AF). The VISITAG Module, an automatic annotation system that takes account of catheter stability and contact force (CF), might be useful in accomplishing this.Methods and Results:In 49 patients undergoing VISITAG-guided AF ablation (group A), we set the following automatic annotation criteria: catheter stability range of motion ≤1.5 mm, duration ≥5 s, CF ≥5 g, time ≥25% and tag diameter at 6 mm. We used ablation >20 s and force-time integral >150 gs at each site, then moved to the next site where a new tag appeared that overlapped with the former tag. Results and outcome were retrospectively compared for 42 consecutive patients undergoing CF-guided AF ablation without this algorithm (group B). Successful PVI at completion of the initial anatomical line was more frequent in group A than B (66.3% vs. 36.9%, P=0.0006) while spontaneous PV reconnection was less frequent (14.2% vs. 30.9%, P=0.0014) and procedure time was shorter (138±35 min vs. 180±44 min, P<0.001). One-year success rate off anti-arrhythmic drugs was higher in group A (91.8% vs. 69.1%, log rank P=0.0058).Conclusions:An automated annotation algorithm with an optimal setting reduced acute resumption of left atrium-PV conduction, shortened procedure time, and improved AF ablation outcome.