著者
Kazuhiro Chiku Ai Yamada Yui Shibasaki Yoshiki Makino Taidoh Komatsuzaki Mitsuru Yoshida
出版者
Food Safety Commission, Cabinet Office, Government of Japan
雑誌
Food Safety (ISSN:21878404)
巻号頁・発行日
vol.11, no.2, pp.25-33, 2023 (Released:2023-06-23)
参考文献数
15

We investigated the time-dependent acrylamide formation in mung bean sprouts during stir-frying under high and medium heat conditions. The acrylamide concentration range detected using the 3-mercaptobenzoic acid derivatization LC-MS/MS method was from below 29 ng/g [limit of detection (LOD)] to 6,900 ng/g. We also investigated the acrylamide levels in mung bean sprouts cooked using four methods while retaining their fresh firm texture using the thiosalicyclic acid derivatization LC-MS/MS method. The acrylamide concentration in microwave oven-cooked sprouts was below 16 ng/g (LOD). The samples cooked by stir-frying, parching, or boiling contained an acrylamide concentration above the LOD but below 42 ng/g [limit of quantification (LOQ)], except for one replicate of a stir-fried sample, whose acrylamide concentration was 42 ng/g. Bean sprouts are popular affordable vegetables, and when stir-fried, their acrylamide concentration is assumed to strongly affect the exposure of the Japanese population to acrylamide. Because the acrylamide concentration range of fried bean sprouts is as broad as mentioned above, the selection of a representative concentration value is difficult. A precise survey and data about acrylamide formation in relation to the bean sprout components before heating, their changes occurring during storage, and the cooking methods and conditions used are needed to estimate the exposure of the Japanese to acrylamide. Here, we showed that rinsing the sprouts before frying and frying them for a short time while mixing them well, while retaining the fresh firm texture to avoid burning and shriveling the sprouts is effective in decreasing the amount of acrylamide formed.
著者
Shuichi Shimma Yoshiki Makino Kazuto Kojima Takafumi Hirata
出版者
The Mass Spectrometry Society of Japan
雑誌
Mass Spectrometry (ISSN:2187137X)
巻号頁・発行日
vol.9, no.1, pp.A0086, 2020-07-13 (Released:2020-07-13)
参考文献数
19
被引用文献数
1

Platinum, a transition metal that is widely used in anti-cancer agents, also results in the development of nephropathy due to severe adverse reactions caused by platinum-induced nephrotoxicity. Reports on imaging with metals other than platinum remain are limited, even in preclinical studies. Furthermore, most of these are case reports, and the relationship between the distribution of the metal and clinical observations in human samples is not well understood. Here we report on visualizing lanthanum (139La), a component of Fosrenol, which is usually used for the treatment of hyperphosphatemia. Gastric inflammation, also known as hemorrhagic gastritis, is the main adverse event caused by Fosrenol. To conduct this study, 139La was visualized in gastric biopsy samples obtained from a patient using quantitative laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). We also compared the distribution of 139La in tissue and histochemical results. The areas where 139La accumulated corresponded to the macrophage-positive areas observed in immunohistochemistry studies using an anti-CD68 antibody. In contrast, we observed a debris-like crystal morphology in hematoxylin and eosin staining tissues. The debris was also associated with 139La accumulation. The abnormal accumulation of 139La crystals caused the observed inflammation. This phenomenon was previously characterized, but this is the first report in which 139La distribution and histochemical results are compared using LA-ICP-MS.
著者
Toshihiro Suzuki Shuhei Sakata Yoshiki Makino Hideyuki Obayashi Seiya Ohara Kentaro Hattori Takafumi Hirata
出版者
The Mass Spectrometry Society of Japan
雑誌
Mass Spectrometry (ISSN:2187137X)
巻号頁・発行日
vol.7, no.1, pp.A0065-A0065, 2018-02-23 (Released:2018-03-01)
参考文献数
14
被引用文献数
37

We report on the development of a software program named iQuant2 which creates visual images from two-dimensional signal intensity data obtained by a laser ablation-ICP-mass spectrometry (LA-ICPMS) technique. Time-resolved signal intensity profiles can be converted to position resolved signal intensity data based on the rastering rate (μm s−1) of the laser ablation. Background signal intensities obtained without laser ablation (gas blank) are used as the background, and all of the blank-subtracted intensity data can be used for the imaging analysis. With this software, deformation of the created image can be corrected visually on a PC screen. The line profile analysis between the user-selected points can be observed using the iQuant2 software. To accomplish this, data points on the profile line were automatically calculated based on the interpolation between the analysis points. The resulting imaging data can be exported and stored as JPEG, BMP or PNG formats for further processing. Moreover, a semi-quantitative analysis can be made based on the coupling of the external correction of the RSF (relative sensitivity factor) using NIST SRM610 with normalization of the corrected signal intensity data being 100%. The calculated abundance data for major elements are in reasonable agreement with the values obtained by electron probe micro analyzer (EPMA). With the software developed in this study, both the rapid imaging and semi-quantitative determinations can be made.