著者
Yusuke Ayabe Kohei Hamamoto Yoshikazu Yoshino Yoshimasa Ikeda Emiko Chiba Hironao Yuzawa Noriko Oyama-Manabe
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.tn.2021-0106, (Released:2021-12-11)
参考文献数
11
被引用文献数
3

A flow-diverter (FD) device is a well-established tool for the treatment of unruptured intracranial aneurysms. Time-of-flight (TOF) MR angiography (MRA) is widely used for postoperative assessment after the treatment with FD; however, it cannot fully visualize intra-aneurysmal and intrastent flow signals due to the magnetic susceptibility from the FD. Recently, the utility of MRA with ultra-short TE (UTE) sequence and arterial spin labeling technique in assessing the therapeutic efficacy of intracranial aneurysms treated with metallic devices has been reported, but long image acquisition time is one of the drawbacks of this method. Herein, we introduce a novel UTE MRA using the subtraction method that enables the reduction in susceptibility artifacts with a short image acquisition time.
著者
Kodai Murasawa Masato Takamura Masayoshi Kumagai Yoshimasa Ikeda Hiroshi Suzuki Yoshie Otake Takayuki Hama Shinsuke Suzuki
出版者
The Japan Institute of Metals and Materials
雑誌
MATERIALS TRANSACTIONS (ISSN:13459678)
巻号頁・発行日
pp.M2017380, (Released:2018-06-01)
参考文献数
22
被引用文献数
6

Neutron diffraction profile analysis using the whole profile fitting method is useful for obtaining microscopic information on metallic materials. To determine an appropriate fitting approach for obtaining reasonable and non-arbitrary results, we applied diffraction line profile analyses using the Convolutional Multiple Whole Profile (CMWP) method to diffraction patterns obtained using the Engineering Materials Diffractometer (TAKUMI, BL19) at the Materials and Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). The tensile specimens of 780 MPa grade bainitic steel were uniaxially stretched until the plastic strain reached a value of 0.05. We performed CMWP analyses on the obtained diffraction patterns during tensile test with various initial parameters of dislocation density and crystallite size. These parameters were optimized in the fitting procedures to minimize the weighted sums of squared residuals (WSSRs). Following this approach, we found that unsuitable initial parameter values resulted in unreasonable convergence. Therefore, initial fitting parameters should be chosen to ensure that the initial profiles are as broad as possible. Reasonable results were obtained following this suggestive approach even when the strain anisotropy parameter is set to arbitrary values.