著者
Takao Tsuchiya Yusuke Makino Yu Teshima Shizuko Hiryu
出版者
ACOUSTICAL SOCIETY OF JAPAN
雑誌
Acoustical Science and Technology (ISSN:13463969)
巻号頁・発行日
vol.44, no.2, pp.101-109, 2023-03-01 (Released:2023-03-01)
参考文献数
28
被引用文献数
2

This paper reports on the implementation of a moving sound source and receiver with directivity in the two-dimensional finite-difference time-domain (FDTD) method. A two-dimensional fundamental solution of a moving monopole source is theoretically derived. Then, a fundamental solution of a moving dipole source is obtained by differentiating the fundamental solution of a monopole source in space. Finally, the directivity of moving monopole, dipole, and cardioid sources is theoretically derived. Numerical experiments performed on the two-dimensional sound field showed that the effect of moving velocity on amplitude differs for the monopole and dipole sources. Furthermore, it was found that directivity characteristics of dipole and cardioid sources vary depending on the beam steering angle and moving direction. The present method can be accurately applied to the moving sound source and receiver with directivity.
著者
Yusuke Makino Megumi Ueno Yoshimi Shoji Minako Nyui Ikuo Nakanishi Koji Fukui Ken-ichiro Matsumoto
出版者
SOCIETY FOR FREE RADICAL RESEARCH JAPAN
雑誌
Journal of Clinical Biochemistry and Nutrition (ISSN:09120009)
巻号頁・発行日
pp.21-83, (Released:2021-12-25)
参考文献数
9

The quantitative measurement of free radicals in liquid using an X-band electron paramagnetic resonance (EPR) was systematized. Quantification of free radicals by EPR requires a standard sample that contains a known spin amount/concentration. When satisfactory reproducibility of the sample material, volume, shape, and positioning in the cavity for EPR measurements can be guaranteed, a sample tested and a standard can be directly compared and the process of quantification can be simplified. The purpose of this study was to simplify manual quantitative EPR measurement. A suitable sample volume for achieving a stable EPR intensity was estimated. The effects of different solvents on the EPR sensitivity were compared. The stability and reproducibility of the EPR intensity of standard nitroxyl radical solutions were compared among different types of sample tubes. When the sample tubes, sample volumes, and/or solvents were the same, the EPR intensity was reproduced with an error of 2% or less for μM samples. The quantified sample and the standard sample in the same solvent and the same volume drawn into the same sample tube was able to be directly compared. The standard sample for quantification should be measured just before or after every daily experiment.