This paper describes results of a numerical simulation and an exergy analysis focusing on the influence of piping thermal insulation on thermal comfort and resource consumption related to hot water floor heating during night time. In a case, pipe length is 1m indoor and 4m outdoor, changing from polyethylene foam 10mm to urethane foam 30mm can reduce warm exergy consumption within the pipe from the boiler to the inlet of the floor in 68%. At the same time, the seasonal median of the room air temperature at am 6:00 can be raised from 15.5°C to 20.0°C. Improving thermal insulation of piping increases radiant and convective warm exergy from the floor two times and four times, even if hot water temperature at the outlet of the boiler is the same.

言及状況

外部データベース (DOI)

Twitter (1 users, 4 posts, 11 favorites)

@akupon_2021 保温ウレタン10mmで10%、30mmで31%、60mmで55%熱損失が減るという研究結果を元に、私は温水配管だけは保温材巻いてますが、一方通行の給湯管はコスパ悪い気がします。満足度は間違いなくあがりますね
@bokuranoie0511 温水がぐるぐる回る、床暖房の配管なら効果あると思いますが、ただのお湯が出る配管って、保温材巻く効果あるんですかね? 我が家は、これを参考に床暖房配管だけやってます。 https://t.co/tUVTCGcvya
@toriismart 床暖房の配管って追加断熱してますか?この方がコスパ良さそう。 ピンクの断熱材の上からさらに分厚い断熱をかけて、放熱を防ぐ。 https://t.co/tUVTCGcvya
ガス温水式床暖房のパイプでの放熱は、本当に勿体無いと思う。特に我が家は床断熱なので、床下の気温は冬場は10度以下。床暖房の温水は60度タイプだから床よりもパイプで熱損失してしまいそう。自分で床下潜って追加断熱した。ガス会社からしたら、やめて欲しい余計な事。 https://t.co/k9vJtlpV57