著者
佐藤 正一 道木 慎二 石田 宗秋
出版者
一般社団法人 電気学会
雑誌
電気学会論文誌D(産業応用部門誌) (ISSN:09136339)
巻号頁・発行日
vol.124, no.5, pp.464-470, 2004 (Released:2004-08-01)
参考文献数
8
被引用文献数
8 12

This paper deals with the high-frequency equivalent circuits of permanent magnet synchronous motor (PMSM) driven by a PWM inverter. The leakage current (common-mode current) flows through stray capacitance among stator windings and iron core (frame) of an synchronous motor at the switching instants of inverter transistors. A high-frequency equivalent circuits of PMSM are derived based on the frequency characteristics of the high-frequency zero-phase-impedance and line-to-line-impedance of synchronous motor. The validity of the proposed equivalent circuit is confirmed by simulation considering parasitic capacitance of the inverter.