著者
Yuka Kawada Akira Yamada Shinji Jinno Chihiro Nakashima Naoki Hoshino Sayano Ueda Meiko Hoshino Sayuri Yamabe Kayoko Takada Kunihiko Sugimoto Hideo Izawa
出版者
Fujita Medical Society
雑誌
Fujita Medical Journal (ISSN:21897247)
巻号頁・発行日
pp.2022-038, (Released:2023-08-28)
参考文献数
22

Objectives: We aimed to identify which resting echocardiographic parameters can detect asymptomatic or mildly symptomatic patients with primary mitral regurgitation (MR) who require exercise stress echocardiography (ESE) to determine their suitability for surgery.Methods: We examined 56 consecutive patients with primary moderate/severe MR who underwent ergometer-based ESE. Patients who met the surgical indications at rest were excluded. Eligible patients were divided into Group I (pulmonary artery systolic pressure [PASP] during exercise >60 mmHg; n=11) and Group II (PASP during exercise ≤60 mmHg; n=30).Results: Forty-one patients were included. Group I was significantly older (65±12 vs. 54±14 years, P=0.042) and had significantly higher serum N-terminal pro-B-type natriuretic peptide concentrations than Group II (351±278 vs. 125±163 pg/mL, P=0.002). The univariate analysis demonstrated that peak E wave velocity (Group I vs. Group II: 125±45 vs. 101±24 cm/sec, P=0.050), left ventricular (LV) end-diastolic diameter index (32±4 vs. 30±3 mm/m2, P=0.035), and left atrial volume index (LAVI; 45±14 vs. 30±11 mL/m2, P=0.008) were predictors of increased PASP during exercise. In the multivariate analysis, resting LAVI best predicted exercise-induced pulmonary hypertension (hazard ratio 1.081 [95% confidence interval 1.009–1.158], P=0.028), with a cutoff value of 37 mL/m2.Conclusions: In asymptomatic or mildly symptomatic patients with primary moderate/severe MR, increased resting LAVI indicates the requirement for ESE, even without LV dilatation.
著者
Noriyuki Fujima Koji Kamagata Daiju Ueda Shohei Fujita Yasutaka Fushimi Masahiro Yanagawa Rintaro Ito Takahiro Tsuboyama Mariko Kawamura Takeshi Nakaura Akira Yamada Taiki Nozaki Tomoyuki Fujioka Yusuke Matsui Kenji Hirata Fuminari Tatsugami Shinji Naganawa
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2023-0047, (Released:2023-08-01)
参考文献数
123
被引用文献数
4

Due primarily to the excellent soft tissue contrast depictions provided by MRI, the widespread application of head and neck MRI in clinical practice serves to assess various diseases. Artificial intelligence (AI)-based methodologies, particularly deep learning analyses using convolutional neural networks, have recently gained global recognition and have been extensively investigated in clinical research for their applicability across a range of categories within medical imaging, including head and neck MRI. Analytical approaches using AI have shown potential for addressing the clinical limitations associated with head and neck MRI. In this review, we focus primarily on the technical advancements in deep-learning-based methodologies and their clinical utility within the field of head and neck MRI, encompassing aspects such as image acquisition and reconstruction, lesion segmentation, disease classification and diagnosis, and prognostic prediction for patients presenting with head and neck diseases. We then discuss the limitations of current deep-learning-based approaches and offer insights regarding future challenges in this field.
著者
Kazuki Oyama Fumihito Ichinohe Akira Yamada Yoshihiro Kitoh Yasuo Adachi Hayato Hayashihara Marcel D. Nickel Katsuya Maruyama Yasunari Fujinaga
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0035, (Released:2022-08-23)
参考文献数
13
被引用文献数
2

Purpose: The optimal temporal resolution for free-breathing dynamic contrast-enhanced MRI (FBDCE-MRI) of the pancreas has not been determined. This study aimed to evaluate the appropriate temporal resolution to achieve good image quality and to perform pharmacokinetic analysis in FBDCE-MRI of the pancreas using golden-angle radial sparse parallel (GRASP).Methods: Sixteen participants (53 ± 15 years, eight females) undergoing FBDCE-MRI were included in this prospective study. Images were retrospectively reconstructed at four temporal resolutions (1.8, 3.0, 4.8, and 7.8s). Two radiologists (5 years of experience) evaluated the image quality of each reconstructed image by assessing the visualization of the celiac artery (CEA), the common hepatic artery, the splenic artery, each area of the pancreas, and artifacts using a 5-point scale. Using Tissue-4D, pharmacokinetic parameters were calculated for each area in the reconstructed images at each temporal resolution for 16 examinations, excluding two with errors in the pharmacokinetic modeling analysis. Friedman and Bonferroni tests were used for analysis. A P value < 0.05 was considered statistically significant.Results: During vascular assessment, only scores for the CEA at 7.8s were significantly lower than the other temporal resolutions. Scores of all pancreatic regions and artifacts were significantly lower at 1.8s than at 4.8s and 7.8s. In the pharmacokinetic analysis, all volume transfer coefficients (Ktrans), rate constants (Kep), and the initial area under the concentration curve (iAUC) in the pancreatic head and tail were significantly lower at 4.8s and 7.8s than at 1.8s. iAUC in the pancreatic body and extracellular extravascular volume fraction (Ve) in the pancreatic head were significantly lower at 7.8s than at 1.8s.Conclusion: A temporal resolution of 3.0s is appropriate to achieve image quality and perform pharmacokinetic analysis in FBDCE-MRI of the pancreas using GRASP.
著者
山田 晶 AKIRA YAMADA 京都大学
巻号頁・発行日
vol.2, pp.1-20, 2001-03-31