著者
Katsuyuki MORISHITA Hiroshi KARASUNO Yuka YOKOI Kazunori MOROZUMI Hisayoshi OGIHARA Toshikazu ITO Takayuki FUJIWARA Tetsuya FUJIMOTO Koji ABE
出版者
日本理学療法士協会
雑誌
Journal of the Japanese Physical Therapy Association (ISSN:13441272)
巻号頁・発行日
vol.17, no.1, pp.1-7, 2014 (Released:2014-12-20)
参考文献数
32
被引用文献数
19

Purpose: This study aimed to clarify the effects of therapeutic ultrasound on intramuscular local blood circulation (and oxygen dynamics) using near-infrared spectroscopy (NIRS). Participants: The participants were 11 healthy males. Methods: All participants performed all three trials; (1) the ultrasound (US group), (2) without powered ultrasound (placebo group), and (3) rest (control group). Ultrasound was applied at 3 MHz, 1.0 W/cm2, and 100% duty cycle for 10 minutes. Evaluation index were oxygenated, deoxygenated, and total hemoglobin (Hb) concentrations in the intramuscular and skin surface temperature (SST). The experimental protocol was a total of 40 minutes, that is, 10 minutes before trial (rest), 10 minutes during the trial (ultrasound, placebo, and control), and 20 minutes after trial (rest). The NIRS and SST data collected before and after the trial were divided into 5 minutes intervals for further analysis. Results: Oxygenated and total hemoglobin levels were significantly higher in the US group than in the placebo and control groups for the 20 minutes after ultrasound ( p < 0.01). The SST was significantly higher in the US group than in the control for 15 minutes after ultrasound ( p < 0.05), while it was significantly lower in the placebo group than in the US and control groups for 20 minutes after the trials ( p < 0.01). Conclusion: The effects of ultrasound were maintained for 20 minutes after the trial on intramuscular blood circulation and oxygen dynamics. These effects were caused by a combination of thermal and mechanical effects of the ultrasound.
著者
Katsuyuki Morishita Hiroshi Karasuno Yuka Yokoi Kazunori Morozumi Hisayoshi Ogihara Toshikazu Ito Masaaki Hanaoka Takayuki Fujiwara Tetsuya Fujimoto Koji Abe
出版者
理学療法科学学会
雑誌
Journal of Physical Therapy Science (ISSN:09155287)
巻号頁・発行日
vol.26, no.5, pp.711-715, 2014 (Released:2014-05-29)
参考文献数
23
被引用文献数
7 29

[Purpose] This study aimed to clarify the effects of therapeutic ultrasound on range of motion and stretch pain and the relationships between the effects. [Subjects] The subjects were 15 healthy males. [Methods] Subjects performed all three interventions: (1) ultrasound (US group), (2) without powered ultrasound (placebo group), and (3) rest (control group). Ultrasound was applied at 3 MHz with an intensity of 1.0 W/cm2 and a 100% duty cycle for 10 minutes. The evaluation indices were active and passive range of motion (ROM), stretch pain (visual analog scale; VAS), and skin surface temperature (SST). The experimental protocol lasted a total of 40 minutes; this was comprised of 10 minutes before the intervention, 10 minutes during the intervention (US, placebo, and control), and 20 minutes after the intervention. [Results] ROM and SST were significantly higher in the US group than in the placebo and control groups for the 20 minutes after ultrasound, though there was no change in stretch pain. [Conclusion] The effects of ultrasound on ROM and SST were maintained for 20 minutes after the intervention. The SST increased with ultrasound and decreased afterwards. Additionally, the SST tended to return to baseline levels within 20 minutes after ultrasound exposure. Therefore, these effects were caused by a combination of thermal and mechanical effects of the ultrasound.
著者
Hiroshi Karasuno Kazunori Morozumi Takayuki Fujiwara Ah Cheng Goh Iwao Yamamoto Fujitoshi Senga
出版者
The Society of Physical Therapy Science
雑誌
Journal of Physical Therapy Science (ISSN:09155287)
巻号頁・発行日
vol.17, no.2, pp.71-79, 2005 (Released:2006-03-16)
参考文献数
36
被引用文献数
7 9

The purpose of this study was to determine the relationship between the changes in intramuscular blood volume (IMBV) under continuous shortwave diathermy (CSWD) and compare them with the electric hot pack (EHP). The subjects consisted of 41 healthy adults, who received one of three interventions: CSWD (n=17), EHP (n=12), or no intervention (Controls: n=12). Analyses were done of the values obtained five minutes preceding the intervention (T1), during the intervention (T2), and after the intervention (T3). CSWD was applied with an output of 80 W. Both CSWD and EHP were applied for 10 min. Changes in IMBV of the right medial gastrocnemius muscle were evaluated using near-infrared spectroscopy (NIRS). Oxy-hemoglobin (oxy-Hb), deoxy-hemoglobin (deoxy-Hb), and total-hemoglobin (total-Hb) were measured using NIRS. At T2 in the CSWD trial, the integration values of oxy-Hb and total-Hb were significantly increased compared with those of the controls (p<0.01), and they were significantly increased compared with those of both the controls and the EHP trial (p<0.01) at T3 of the CSWD trial. The study results verified that IMBV increases as a result of the local thermal effect of CSWD, and also suggest that CSWD is more effective at enhancing IMBV than EHP.