著者
Yume Suzuki Naoki Toma Katsuhiro Inoue Tomonori Ichikawa Hirofumi Nishikawa Yoichi Miura Masashi Fujimoto Ryuta Yasuda Masayuki Maeda Hidenori Suzuki
出版者
The Japanese Society for Neuroendovascular Therapy
雑誌
Journal of Neuroendovascular Therapy (ISSN:18824072)
巻号頁・発行日
pp.oa.2023-0016, (Released:2023-06-15)
参考文献数
30

Objective: We aimed to evaluate the efficacy of the “improved motion-sensitized driven-equilibrium (iMSDE)”-prepared T1-weighted black blood (T1-BB) MRI for monitoring treatment effect with a flow diverter (FD) for cerebral aneurysms.Methods: Following the exclusion of concomitant coiling and retreatment cases from 60 consecutive cases of cerebral aneurysms treated with FDs at our institution, 32 with imaging data were included in the analysis. Detectability of residual blood flow within the aneurysms was validated as follows: 1) comparison of MRI sequences (iMSDE-prepared T1-BB images, T1-weighted images [ T1WI], and time-of-flight [ TOF]-MRA) in cases of incompletely occluded aneurysms and 2) comparison of angiography and MRI sequences in the same period.Results: 1) The probability of diagnosing intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p <0.001). 2) The diagnostic accuracy of residual aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB than that with T1WI (p = 0.032). Furthermore, in cases of incomplete occlusion, the probability of detecting intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p = 0.023).Conclusion: Our results demonstrated that iMSDE-prepared T1-BB could help distinguish between blood flow and thrombus within the aneurysms after FD treatment, especially in the early stages of FD treatment.
著者
Tomonori Ichikawa Ryuta Yasuda Atsushi Yamamoto Hirofumi Nishikawa Masashi Fujimoto Yoichi Miura Naoki Toma Hidenori Suzuki
出版者
The Japanese Society for Neuroendovascular Therapy
雑誌
Journal of Neuroendovascular Therapy (ISSN:18824072)
巻号頁・発行日
pp.cr.2022-0028, (Released:2022-10-21)
参考文献数
11

Objective: We describe 3 cases with folding deformation of a PRECISE (Cordis, Miami, FL, USA) stent in carotid artery stenting (CAS).Case Presentations: The 3 cases with cervical carotid stenosis consisted of 3 males around 80 years old and included 2 symptomatic lesions. During CAS, distal embolic protection was established using a Mo.Ma (Medtronic, Minneapolis, MN, USA) along with a filter device in 2 cases and an Optimo (Tokai Medical Products, Aichi, Japan) along with a filter device in 1 case. For the filter device, either FilterWire EZ (Boston Scientific, Natick, MA, USA) or Spider FX (Covidien, Irvine, CA, USA) was employed. In all cases, a PRECISE stent was deployed after pre-dilation performed using a percutaneous transluminal angioplasty (PTA) balloon with the diameter of 2.5 to 3 mm. Post-dilation was performed after the stent deployment using a PTA balloon whose diameter was about 80% of that of the normal distal internal carotid artery. In all cases, cone-beam CT taken after the deployment of a stent showed folding deformation of the stent. In 2 cases, heavily calcified plaque hampered self-expansion of the stent, which resulted in the stent deformation. On the other hand, in the remaining 1 case, a distal shaft of the Mo.Ma caused the stent deformation, which was likely accelerated by head rotation and cervical compression that was performed to resolve difficulties for a filter retrieval device to pass through the stent, and post-dilation after the stenting.Conclusion: Heavily calcified plaque and a distal shaft of a Mo.Ma would result in stent deformation.
著者
Yoichi MIURA Yume SUZUKI Hideki KANAMARU Masato SHIBA Ryuta YASUDA Naoki TOMA Hidenori SUZUKI
出版者
The Japan Neurosurgical Society
雑誌
Neurologia medico-chirurgica (ISSN:04708105)
巻号頁・発行日
pp.oa.2020-0430, (Released:2021-06-01)
参考文献数
25
被引用文献数
7

The present study was conducted to investigate whether non-fasting serum triglyceride (TG) levels can be used to assess a risk for the progression of carotid artery stenosis. This was a single-center retrospective study. Consecutive 96 patients with ≥50% stenosis of at least unilateral cervical internal carotid artery and normal fasting serum low-density lipoprotein cholesterol (LDL-C) levels of ≤140 mg/dL were followed up for at least 1 year (mean, 3.1 years), and clinical variables were compared between patients with and without carotid stenosis progression (≥10% increases in the degree on ultrasonography). Carotid stenosis progression was shown in 21 patients, associated with less frequent treatment with calcium channel blockers (CCBs), higher non-fasting TG and glucose levels. In carotid artery-based analyses including <50% stenosis side, stenosis progression was shown in 23 of 121 arteries except for those with complete occlusion and less than 1-year follow-up period because of carotid artery stenting (CAS) or carotid endarterectomy (CEA). Stenosis progression was more frequently observed in symptomatic and/or radiation-induced lesions, and was also accompanied with less frequent treatment with CCBs, higher non-fasting TG and glucose levels in carotid artery-based analyses. The receiver operating characteristic (ROC) curve analyses revealed that a cutoff value of non-fasting TG to discriminate carotid stenosis progression was 169.5 mg/dL for carotid arteries with the baseline stenosis of <50%, and 154.5mg/dL for those of ≥50%. Non-fasting TG level was an independent risk factor of carotid stenosis progression, and more strict control of non-fasting TG may be necessary for higher degree of carotid artery stenosis.