著者
Masafumi Nakayama Nobuhiro Tanaka Kunihiro Sakoda Yohei Hokama Kou Hoshino Yo Kimura Masashi Ogawa Jun Yamashita Yuichi Kobori Takashi Uchiyama Yoshifusa Aizawa Akira Yamashina
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.79, no.3, pp.530-536, 2015-02-25 (Released:2015-02-25)
参考文献数
38
被引用文献数
20 19

Background:Papaverine is useful for evaluating the functional status of a coronary artery, but it may provoke malignant ventricular arrhythmia (VA). The aim of this study was to investigate the incidence, and clinical and ECG characteristics of patients with papaverine-induced VAs.Methods and Results:The 182 consecutive patients underwent fractional flow reserve (FFR) measurement of 277 lesions. FFR was determined after intracoronary papaverine administration by standard procedures. The clinical and ECG characteristics were compared between patients with and without ventricular tachycardia (VT: ≥3 successive premature ventricular beats (PVBs), or ventricular fibrillation (VF)). After papaverine administration, the QTc interval, QTUc interval, and T-peak to U-end interval were prolonged significantly. Single PVBs on the T-wave or U-wave type developed in 29 patients (15.9%). Polymorphic VT (torsade de pointes) occurred in 5 patients (2.8%), and of those, VF developed in 3 patients (1.7%). No clinical and baseline ECG parameters were predictors for VT or VF except for sex and administration of papaverine into the left coronary artery. Excessive prolongation of QT (or QTU), T-peak to U-end intervals and giant T-U waves were found immediately prior to the ventricular tachyarrhythmias (VTAs), which were unpredictable from the baseline data.Conclusions:Intracoronary administration of papaverine induced fatal VTAs, although the incidence is rare. Excessive prolongation of the QT (and QTU) interval appeared prior to VTAs; however, they were unpredictable. (Circ J 2015; 79: 530–536)
著者
Masafumi Nakayama Takashi Uchiyama Nobuhiro Tanaka Takaaki Ohkawauchi Shunsuke Miwa Nobuhiro Hijikata Yuichi Kobori Hitoshi Matsuo Kiyotaka Iwasaki
出版者
The Japanese Circulation Society
雑誌
Circulation Reports (ISSN:24340790)
巻号頁・発行日
vol.2, no.11, pp.665-673, 2020-11-10 (Released:2020-11-10)
参考文献数
38
被引用文献数
2

Background:We hypothesized that the intracoronary-electrocardiogram (IC-ECG)-based pressure index would be more stable and precise than the instantaneous flow reserve (iFR). We investigated the usefulness of the IC-ECG-based pressure index for diagnosing myocardial ischemia.Methods and Results:Thirty-seven consecutive patients with coronary stenosis requiring physiological assessment were enrolled in the study. iFR was measured at rest and under hyperemia in 51 and 40 lesions, respectively. The IC-ECG-triggered distal pressure (Pd)/aortic pressure (Pa) ratio (ICE-T) was defined as the mean Pd/Pa ratio in the period corresponding to the isoelectric line. The ICE-T was significantly lower than the iFR both at rest and during hyperemia (P<0.00001 for both). Fluctuations in the ICE-T pressure parameters (Pd/Pa, Pa, and Pd) were significantly smaller than those of iFR both at rest and during hyperemia. The diagnostic accuracy of predicting a fractional flow reserve (FFR) ≤0.80 of the ICE-T at rest was significantly higher than that of iFR (P=0.008). Receiver operating characteristic curve analyses showed that the ICE-T predicts FFR ≤0.80 more accurately than the iFR (area under curve 0.897 vs. 0.810 for ICE-T and iFR, respectively).Conclusions:We identified the period in the IC-ECG in which resting Pd/Pa was low and constant. The IC-ECG-based algorithm may improve the accuracy of diagnosing myocardial ischemia, without increasing invasiveness, compared with pressure-dependent indices.