著者
Hiroo Yamaga Yusuke Tsuboko Tomoaki Terada Kiyotaka Iwasaki
出版者
The Japanese Society for Neuroendovascular Therapy
雑誌
Journal of Neuroendovascular Therapy (ISSN:18824072)
巻号頁・発行日
pp.oa.2021-0099, (Released:2022-07-21)
参考文献数
22

Objective: To facilitate understanding for the safe use of the Wingspan stent, a comprehensive literature analysis was conducted, and incidence rates of 30-day stroke or death before and after the Stenting versus Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis (SAMMPRIS) trial were compared. We also investigated the associations between 30-day stroke or death rate and four lesion vessels, the internal carotid artery (ICA), middle cerebral artery (MCA), basilar artery (BA), and vertebral artery (VA).Methods: We searched MEDLINE, Embase, Web of Science, and Cochrane Library databases. The incidence rates of 30-day stroke or death in pre- and post-SAMMPRIS were compared using forest plots and funnel plots.Results: Thirty studies (15 before and 15 after the SAMMPRIS) were identified, comprising 2071 patients. Post-SAMMPRIS studies showed lower incidence rates of 30-day stroke or death compared to the pre-SAMMPRIS studies (8.5% vs. 5.6%, p = 0.014). The odds ratio of 30-day stroke or death of the post-SAMMPRIS group compared to that of the pre-SAMMPRIS group was 0.64 (95% confidence interval: 0.45–0.92, p = 0.014).The average 30-day stroke or death rates of overall, pre-, and post-SAMMPIS studies were 1.1%, 1.1%, and 1.1% for ICA; 6.2%, 8.8%, and 5.3% for MCA; 0.9%, 6.0%, and 2.7% for VA; and 13.5%, 15.1%, and 12.5% for BA, respectively. The post-SAMMPRIS study group showed significantly lower event rates for the treatment of MCA and VA than the pre-SAMMPRIS group did (p = 0.003 and p = 0.006, respectively). The incidence rates of ischemic and hemorrhagic stroke were 3.5% and 2.0%, respectively.Conclusion: This systematic surveillance study indicated that the modification of the indications for use based on the results of the SAMMPRIS trial for the Wingspan stent was effective in reducing 30-day stroke or death.
著者
Masafumi Nakayama Takashi Uchiyama Nobuhiro Tanaka Takaaki Ohkawauchi Shunsuke Miwa Nobuhiro Hijikata Yuichi Kobori Hitoshi Matsuo Kiyotaka Iwasaki
出版者
The Japanese Circulation Society
雑誌
Circulation Reports (ISSN:24340790)
巻号頁・発行日
vol.2, no.11, pp.665-673, 2020-11-10 (Released:2020-11-10)
参考文献数
38
被引用文献数
2

Background:We hypothesized that the intracoronary-electrocardiogram (IC-ECG)-based pressure index would be more stable and precise than the instantaneous flow reserve (iFR). We investigated the usefulness of the IC-ECG-based pressure index for diagnosing myocardial ischemia.Methods and Results:Thirty-seven consecutive patients with coronary stenosis requiring physiological assessment were enrolled in the study. iFR was measured at rest and under hyperemia in 51 and 40 lesions, respectively. The IC-ECG-triggered distal pressure (Pd)/aortic pressure (Pa) ratio (ICE-T) was defined as the mean Pd/Pa ratio in the period corresponding to the isoelectric line. The ICE-T was significantly lower than the iFR both at rest and during hyperemia (P<0.00001 for both). Fluctuations in the ICE-T pressure parameters (Pd/Pa, Pa, and Pd) were significantly smaller than those of iFR both at rest and during hyperemia. The diagnostic accuracy of predicting a fractional flow reserve (FFR) ≤0.80 of the ICE-T at rest was significantly higher than that of iFR (P=0.008). Receiver operating characteristic curve analyses showed that the ICE-T predicts FFR ≤0.80 more accurately than the iFR (area under curve 0.897 vs. 0.810 for ICE-T and iFR, respectively).Conclusions:We identified the period in the IC-ECG in which resting Pd/Pa was low and constant. The IC-ECG-based algorithm may improve the accuracy of diagnosing myocardial ischemia, without increasing invasiveness, compared with pressure-dependent indices.