著者
Babita Shashni Shinya Ariyasu Reisa Takeda Toshihiro Suzuki Shota Shiina Kazunori Akimoto Takuto Maeda Naoyuki Aikawa Ryo Abe Tomohiro Osaki Norihiko Itoh Shin Aoki
出版者
The Pharmaceutical Society of Japan
雑誌
Biological and Pharmaceutical Bulletin (ISSN:09186158)
巻号頁・発行日
vol.41, no.4, pp.487-503, 2018-04-01 (Released:2018-04-01)
参考文献数
45
被引用文献数
34 65

Detection of anomalous cells such as cancer cells from normal blood cells has the potential to contribute greatly to cancer diagnosis and therapy. Conventional methods for the detection of cancer cells are usually tedious and cumbersome. Herein, we report on the use of a particle size analyzer for the convenient size-based differentiation of cancer cells from normal cells. Measurements made using a particle size analyzer revealed that size parameters for cancer cells are significantly greater (e.g., inner diameter and width) than the corresponding values for normal cells (white blood cells (WBC), lymphocytes and splenocytes), with no significant difference in shape parameters (e.g., circularity and convexity). The inner diameter of many cancer cell lines is greater than 10 µm, in contrast to normal cells. For the detection of WBC having similar size to that of cancer cells, we developed a PC software “Cancer Cell Finder” that differentiates them from cancer cells based on brightness stationary points on a cell surface. Furthermore, the aforementioned method was validated for cancer cell/clusters detection in spiked mouse blood samples (a B16 melanoma mouse xenograft model) and circulating tumor cell cluster-like particles in the cat and dog (diagnosed with cancer) blood samples. These results provide insights into the possible applicability of the use of a particle size analyzer in conjunction with PC software for the convenient detection of cancer cells in experimental and clinical samples for theranostics.
著者
Masato Furuhashi Kazuma Mori Marenao Tanaka Takuto Maeda Megumi Matsumoto Takayo Murase Takashi Nakamura Masayuki Koyama Norihito Moniwa Hirofumi Ohnishi Shigeyuki Saitoh Kazuaki Shimamoto Tetsuji Miura
出版者
The Japan Endocrine Society
雑誌
Endocrine Journal (ISSN:09188959)
巻号頁・発行日
pp.EJ18-0127, (Released:2018-08-02)
被引用文献数
18

Hypouricemia is a high-risk factor of exercise-induced acute kidney injury (EIAKI) probably through a lack of an antioxidant effect of uric acid. Xanthine oxidoreductase (XOR) is an enzyme that catalyzes the formation of uric acid from hypoxanthine and xanthine, leading to an increase in superoxide and reactive oxygen species. Activation of XOR has been proposed to promote oxidative stress-related tissue injury. We measured plasma XOR activity by a sensitive and accurate assay using a combination of liquid chromatography and triple quadrupole mass spectrometry in subjects with relatively low levels of uric acid (≤4.0 mg/dL) who were recruited from 627 subjects (male/female: 292/335) in the Tanno-Sobetsu Study, a population-based cohort. The numbers of subjects with uric acid ≤4.0 mg/dL, ≤3.0 mg/dL and ≤2.0 mg/dL were 72 (11.5%, male/female: 5/67), 13 (2.1%, all females) and 2 (0.3%, both females), respectively. Plasma XOR activities in 5 male subjects were below the median value of the 292 male subjects. In 12 (17.9%) of the 67 female subjects with uric acid ≤4.0 mg/dL, plasma XOR activities were above the upper quartile value of the 335 female subjects. Eleven of the 12 female subjects with high plasma XOR activity and a low uric acid level had liver dysfunction and/or insulin resistance. In conclusion, unexpected high plasma XOR activities were found in some female subjects with relatively low levels of uric acid. Measurement of plasma XOR activity may help to identify hypouricemic patients with a high risk for EIAKI.