著者
Taishi Okuno Masaki Izumo Noriko Shiokawa Shingo Kuwata Yuki Ishibashi Yukio Sato Masashi Koga Kazuaki Okuyama Norio Suzuki Keisuke Kida Yasuhiro Tanabe Yoshihiro J. Akashi
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0503, (Released:2023-11-25)
参考文献数
14

Background: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11–1.32; P=0.13).Conclusions: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.
著者
Shingo Kuwata Masaki Izumo Taishi Okuno Noriko Shiokawa Yukio Sato Masashi Koga Kazuaki Okuyama Yasuhiro Tanabe Tomoo Harada Yuki Ishibashi Yoshihiro J Akashi
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0240, (Released:2023-07-13)
参考文献数
22
被引用文献数
2

Background: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300–8.076; P=0.012) adjusted using inverse probability of treatment weighting.Conclusions: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.
著者
Atsushi Mizuno Takeshi Yamamoto Yasuhiro Tanabe Toru Obayashi Morimasa Takayama Ken Nagao Tokyo CCU Network Scientific Committee
出版者
日本循環器学会
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.79, no.4, pp.889-891, 2015-03-25 (Released:2015-03-25)
参考文献数
11
被引用文献数
4 8

Background:The Pulmonary Embolism Severity Index (PESI) and simplified PESI (sPESI) have not been fully evaluated in Japan, so the present study aimed to evaluate these risk stratification models in the prediction of mortality of affected patients in Japan.Methods and Results:We retrospectively analysed 302 PE patients (63.9±17.2 years of age; 42.4% male) from January 2011 to December 2012 using data from the Tokyo CCU Network. The areas under the receiver-operating characteristic curves were 0.92 (95% confidence interval (CI): 0.88–0.97) for the PESI and 0.88 (95% CI: 0.77–0.98) for the sPESI.Conclusions:Both scores can be used to predict PE mortality in Japan. (Circ J 2015; 79: 889–891)