著者
大野 秀夫 小出 陽子 久野 覚 間野 忠明 山羽 基
出版者
日本建築学会
雑誌
日本建築学会計画系論文集 (ISSN:13404210)
巻号頁・発行日
vol.63, no.509, pp.1-7, 1998
被引用文献数
1

The present paper discusses on the better heating method at the changingroom for aged when they take a bath in winter. The main results are as follows: 1.The significant difference was observed on the psychological responses between the heating condition and non-heating one before bathing. They showed the higher discomfort at the non-heating than the heating conditions. 2.The blood pressure rose less at the warm air blowing condition compared with other two conditions before bathing. It was more effective for the older subjects. 3.They immersed their bodies into the hot bathtab till their skin temperatures rose higher levels at non-heating condition compared to the heating conditions.