著者
鈴木 大隆 北谷 幸恵 岩前 篤 永井 久也 小南 和也 坂本 雄三
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.73, no.627, pp.591-597, 2008-05-30 (Released:2009-02-25)
参考文献数
13
被引用文献数
2 2

There are two points of view for the prevention design of moisture problem in the building insulated envelope. One is the strictly prevention of high moisture condition in the insulated wall cavity. The other one is the permission of short-term high moisture condition, condensation and high moisture content of the wooden material as long as keeping physical durability. If the later standpoint were chosen, the insulated envelope design of every variety for Japan would be possible. Nevertheless, there are no criteria to estimate the damage of physical durability of wood by the biological factors related high moisture condition. The points of this paper are as follows; 1) The importance of estimation damage of woods by the moisture problems is describes. 2) 2 case of hygrothermal steady state experiments were done to get basic acknowledge of woods damage by biological factors considering term, water content, temperature and humidity, physical durability.
著者
高田 和規 遠藤 卓 立松 宏一 村田 さやか 廣田 誠一 北谷 幸恵 鈴木 大隆 羽山 広文
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.82, no.732, pp.165-173, 2017 (Released:2017-02-28)
参考文献数
15
被引用文献数
1 1

The purpose of this study is to quantitatively evaluate the effectiveness of the components of existing PVC windows in the country in providing thermal insulation, to identify the optimal conditions of the components and the insulation performance of windows with the components in the optimal conditions, and to conduct a performance test on samples under the practical specifications for production. We briefly summarize the results below. 1) For the frame, using a method of quality engineering, we examined the reduction in conductive heat flow across each cross-section for multiple regulatory elements, which would contribute to thermal insulation. We then derived the optimal condition (level) for each regulatory element and showed the reduction rate under the optimal condition (sash frame part 19%-21%, fix frame part 6%-10%, mullion frame part 22%). Furthermore, based on the SN ratio, we found that the reduction rate is highest with the following components: inner-frame insulator in the sash frame part and fix frame part, and physical properties of mullion reinforcement in the mullion frame part. 2) As for the glazing part, we examined the specifications of the Low-E film suspended air space of a insulated glass and observed the effect of a Low-E film, optimized the arrangement, and the optimal thickness of the air space for each gas fill. We also examined the thermal transmittance at the center of glass with xenon gas having 3 films (0.29 [W/(m2·K)]), and those at the center of glass with krypton gas having 2 films (0.39 [W/(m2·K)]). 3) We determined the thermal transmittance of the window (0.56 [W/(m2·K)]) with the combined optimal conditions for the frame and glazing parts. In actual manufacturing, however, there are two problems: a technical problem (of forming a metal film inside the frame cross-section and arranging phenolic foam insulator without leaving any space) and a high manufacturing cost (associated with filling xenon gas inside the insulated glass). We therefore examined the insulation performance of samples having practical specifications for production. As a result, we obtained a measured thermal transmittance of 0.63 [W/(m2·K)] in contrast to the calculated value of 0.65 [W/(m2·K)].
著者
永井 久也 鈴木 大隆 北谷 幸恵 岩前 篤 小南 和也 坂本 雄三
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.74, no.638, pp.457-463, 2009-04-30 (Released:2009-11-24)
参考文献数
6
被引用文献数
1 1

There are two points of view for the prevention design of moisture problem in the building insulated envelope. One is the strictly prevention of high moisture condition in the insulated wall cavity. The other one is the permission of short-term high moisture condition, condensation and high moisture content of the wooden material as long as keeping physical durability. If the later standpoint were chosen, the insulated envelope design of every variety for Japan would be possible. Nevertheless, there are no criteria to estimate the damage of physical durability of wood by the biological factors related high moisture condition. In the previous paper, we reported about the concept of the prevention design of moisture problem in the building insulated envelope and the relationships between water content and decay various woods under hygrothermal steady conditions. In this paper, the relationships between water content and decay of various woods under two kinds of hygrothermal transient conditions are shown.
著者
小笠原 一隆 北谷 幸恵
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 平成26年度大会(秋田)学術講演論文集 第4巻 通風・換気 編 (ISSN:18803806)
巻号頁・発行日
pp.121-124, 2014 (Released:2017-11-15)

本研究では、エアコンの能力向上のために換気に着目し、外気の導入箇所をエアコンの吸込部付近とするシステムを提案し、吸込温度を低くすることが機器の運転効率向上に結び付くこと、外気導入を強制的に行うことが建物下部からの冷気侵入抑制につながることを示した。