著者
圓尾 知之 中江 文 前田 倫 高橋−成田 香代子 Morris Shayn 横江 勝 松崎 大河 柴田 政彦 齋藤 洋一
出版者
日本疼痛学会
雑誌
PAIN RESEARCH (ISSN:09158588)
巻号頁・発行日
vol.28, no.1, pp.43-53, 2013-03-10 (Released:2013-04-04)
参考文献数
15
被引用文献数
1 12

Background: The revised version of Short-Form McGill Pain Questionnaire (SF-MPQ-2) has been developed as a tool for measuring both neuropathic and non-neuropathic pain which can be used in studies of epidemiology, pathophysiologic mechanisms, and treatment response. SF-MPQ-2 was expanded and revised from the Short-Form McGill Pain Questionnaire (SF-MPQ-1) pain descriptors by adding symptoms relevant to neuropathic pain and by modifying the response format to a 0 - 10 numerical rating scale. In this study, we translated the SF-MPQ-2 into Japanese. The aim of this study was the validation of a Japanese version of the SF-MPQ-2 in patients with neuropathic pain. Materials and Methods: A total of 110 chronic pain patients from Osaka University Hospital and Nishinomiya Municipal Central Hospital were enrolled in this study, with 87 (47 males, 40 females) patients completing the study. Enrolled patients completed the SF-MPQ-2 which had been translated into Japanese. To evaluate the validity of the SF-MPQ-2 questionnaire, an exploratory factor analysis was performed. For assessment of reliability, we used internal consistency reliability coefficients (Cronbach's alpha coefficient) and the test-retest method test (Intraclass Correlation Coefficient; ICC) for the SF-MPQ-2 total and subscale scores. Validity was evaluated by examining the associations between the SF-MPQ-2 total and subscale scores and other measures. Results: The internal consistency (Cronbach's alpha coefficient; continuous pain; α=0.883, intermittent pain; α=0.856, predominantly neuropathic pain; α=0.905, affective descriptors; α=0.863, total score; α=0.906) and reproducibility coefficient (ICC; continuous pain; ρ=0.793, intermittent pain; ρ=0.750, predominantly neuropathic pain; ρ=0.819, affective descriptors; ρ=0.760, total score; ρ=0.830) were high. There were significant correlations between SF-MPQ-2 and other functional assessments. Conclusion: Our findings showed excellent reliability and validity for the Japanese version of the SF-MPQ-2 in pain patients, and the results of both exploratory and confirmatory factor analyses provided support for four readily interpretable subscales (continuous pain, intermittent pain, pre-dominantly neuropathic pain, and affective descriptors). These results provide a basis for use of the SF-MPQ-2 in future clinical research, including clinical trials of treatments for neuropathic and non-neuropathic pain conditions.
著者
佐野 佑子 神鳥 明彦 島 圭介 田村 康裕 高木 寛 辻 敏夫 野田 正文 東川 史子 横江 勝 佐古田 三郎
出版者
The Society of Instrument and Control Engineers
雑誌
計測自動制御学会論文集 (ISSN:04534654)
巻号頁・発行日
vol.47, no.6, pp.272-281, 2011 (Released:2011-12-19)
参考文献数
13
被引用文献数
1 2

We tested the repeatability of a finger tapping device with magnetic sensors to determine its reliability. This device, which was developed to assist in the diagnosis of movement disorders such as Parkinson's disease (PD) and strokes, measures the distance between the first and index fingers during finger tapping movements (opening and closing the fingers repeatedly). We evaluated three types of repeatability based on ICC (interclass correlation coefficient) and Welch's test (test for equal means in a oneway layout): repeatability when measured at different times, when using different devices, and when using different measurers. We calculated these three types for three finger tapping tasks on both hands for 21 characteristics calculated from finger tapping waveforms. Results demonstrated that the repeatability when using different devices is high regardless of the task or hand. The repeatability when measuring at different times and when using different measurers is high at some tasks, but not all. One of the finger tapping tasks (finger tapping movement with the largest amplitude and highest velocity), which is used in a conventional PD diagnosis method (UPDRS), does not have enough repeatability, while other tasks show high repeatability. Results also showed that five characteristics have the highest repeatability (ICC ≥ 0.5 or significance probability of Welch's test ≥ 5% in all tasks): “total moving distance,” “average of local minimum acceleration in opening motion,” “average of local minimum acceleration in closing motion,” “average of local maximum distance” and “average of local minimum velocity”. These results clearly demonstrate the strong repeatability of this device and lead to more precise diagnosis of movement disorders.