著者
Akihisa Kodaira Hiroyasu Koizumi Haruto Hiraba Yoshimasa Takeuchi Mari Koike Saiji Shimoe
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.22-0036, (Released:2022-05-18)
参考文献数
55
被引用文献数
3

Recently in Japan, due to the increased prices of palladium and gold, cast titanium restorations have been included in the Japanese national health insurance system. The purpose of this review was to survey the available literature on titanium bonding systems, focusing on the adhesive monomer in the luting agent in order to expand the application of resin-bonded fixed prostheses made of titanium or titanium alloys. It was found that adhesive monomers are effective for bonding to titanium, and provide results equal to the procedures of silanization and tribochemical silica coating. A primer or a luting agent, including 10-methacryloyloxydecyl dihydrogen phosphate (MDP), methacryloyloxyalkyl thiophosphate derivative (MEPS), 6-methacryloxyhexyl phosphonoacetate (6-MHPA), and 4-methacryloyloxyethl trimellitate anhydride (4-META) promotes bonding characteristics between titanium and the resin material.
著者
Haruto Hiraba Hiroyasu Koizumi Akihisa Kodaira Kosuke Takehana Takayuki Yoneyama Hideo Matsumura
出版者
Japan Prosthodontic Society
雑誌
Journal of Prosthodontic Research (ISSN:18831958)
巻号頁・発行日
pp.JPR_D_21_00308, (Released:2022-05-14)
参考文献数
32
被引用文献数
1

Purpose: To clarify the effect of a multi-purpose primer combining several functional monomers on two prosthodontic materials (cast titanium and a gold alloy) after airborne-particle abrasion.Methods: Disk-shaped adherends were prepared from cast titanium (CP Titanium JIS2) and a gold alloy (Casting Gold M.C. Type IV). A silane-containing two-liquid primer (M&C primer (MC)) and two silane-free single-liquid primers (Alloy Primer (AP) and V-Primer (VP)) were used as surface-treatment agents. The shear bond strengths were determined before and after thermocycling to evaluate the adhesive durability, and the results were compared using a non-parametric statistical analysis. The effect of airborne-particle abrasion with alumina on the titanium surface was analyzed by X-ray photoelectron spectroscopy (XPS).Results: There was no significant difference in bond strength between the MC and AP before and after thermocycling, whereas VP showed significantly lower values. XPS revealed that the titanium acquired hydrophilic properties after the airborne-particle abrasion.Conclusions: The novelty of this study is that it shows that the presence/absence of the silane had no effect on the bonding of cast titanium with an acrylic resin. The study also showed that the multi-purpose primer can be used without any problems with both cast titanium and gold alloy, in combination with airborne-particle abrasion with alumina.
著者
Kosuke TAKEHANA Hiroyasu KOIZUMI Haruto HIRABA Akihisa KODAIRA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-181, (Released:2021-12-28)
参考文献数
23

This study assessed the effect of a primer containing 10-methacryloyloxydecyl-(2-thiohydantoin-4-yl)propionate (MDTHP) on the bonding of noble metal alloys to an acrylic resin. Three noble metal alloys were selected as adherends, and V-Primer containing 6-(4-vinylbenzyl-n-propyl)amino-1,3,5-triazine-2,4-dithione was used as a comparative control. The disk specimens of each noble metal alloy were wet-ground and divided into three conditions: specimens primed with MDTHP primer or V-Primer, and specimens without priming. An acrylic resin was bonded to each specimen, and the specimens were performed the shear bond test. The MDTHP primer showed higher shear bond strength than the V-Primer for all specimens. X-ray photoelectron spectroscopic analysis showed that MDTHP was adsorbed on the Au-Pt-Pd alloy surface even after acetone cleaning. MDTHP binds not only with Cu but also with Au and Ag, promoting the bond strength of noble metal alloys. The effectiveness of MDTHP on dental noble metal alloys was suggested.
著者
Wataru MIKAMI Hiroyasu KOIZUMI Akihisa KODAIRA Haruto HIRABA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-137, (Released:2021-09-02)
参考文献数
26
被引用文献数
2

This study assessed the gloss and surface roughness of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites corroded with acidulated phosphate fluoride (APF) application. One ceramic block, ten CAD/CAM resin composites for premolars, and four CAD/CAM resin composites for molars were assessed. The surface topography of the materials before and after APF application was observed using an electron microscope. The results were analyzed by Wilcoxon signed-rank test and Dunnett’s many to one test (p<0.05). Gloss after APF application was significantly lower for all CAD/CAM resin composites except Artesano. Ra after APF application was significantly higher for all CAD/CAM resin composites except Artesano, Dentcraft HR Block, and Estelite P Block, and Sa was significantly higher for all CAD/CAM resin composites. Irregular surface topography was observed after APF application and the surface features differed among the materials. Therefore, APF application may be detrimental to the surface properties of CAD/CAM resin composites.
著者
Mika Furuchi Momoko Shimada Haruto Hiraba Akihisa Kodaira Akiko Hashiguchi Atsushi Kamimoto
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.21-0224, (Released:2021-06-18)
参考文献数
23

Purpose: To evaluate the influence of polymerization methods and a metal priming agent on the bond strength between gold alloy for metal ceramic restorations and dual-cure-type resin luting agents, and on the strength and hardness of the luting agents.Methods: A total of 154 disks cast by a gold alloy were treated with or without a metal priming agent. One of the three luting agents was applied on the disk. The luting agent was either chemically or dual-polymerized. The shear bond strength was measured both before and after thermocycling. In addition, scanning electron microscope (SEM) observation, flexural strength test, and Knoop hardness test were performed.Results: Significant differences among the luting agents were observed in terms of bond strength and flexural strength. Significant differences between chemically and dual-polymerized luting agents were observed regarding shear bond strength, flexural strength, and Knoop hardness before thermocycling. The application of the priming agent was effective only for a luting agent.Conclusion: Both bond strength and flexural strength differed among three luting agents. The effect of the priming agent on bond strength differed among the luting agents. Both the bond and flexural strength of a chemically polymerized luting agent differed before or after thermocycling.
著者
Hideo Matsumura Katsunori Kojima Shigeru Mio Takashi Yamamoto Akihisa Kodaira Hiroyasu Koizumi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.19-0005, (Released:2020-05-15)
参考文献数
16
被引用文献数
5

The purpose of the current study was to synthesize a methacrylate monomer with a thiohydantoin structure. In a flask, (2-thiohydantoin-4-yl) propionic acid, 10-hyroxydecyl methacrylate, 4-dimethylaminopyridine, and tetrahydrofuran (THF) were placed in a nitrogen atmosphere. A THF solution of N,N’-dicyclohexylcarbodiimide was added and stirred at room temperature. Ethyl acetate and n-hexane were then added to the reaction mixture. The reacted slurry was purified by chromatography with silica gel and hexane-ethyl acetate gradient elution solvent. The structure of the compound was assigned with proton nuclear magnetic resonance spectrum analysis, infrared spectroscopy, and high-resolution mass spectral analysis. The colorless viscous liquid obtained in yield of 49% was characterized as 10-methacryloyloxydecyl-(2-thiohydantoin-4-yl)propionate (MDTHP) or 10-((3-(5-oxo-2-thioxysoimidazolidin-4-yl)propanoyl)oxy)decyl methacrylate (2-THPDM). The MDTHP was soluble to acetone, isopropanol, and methyl methacrylate up to 2.6% or more. This compound could be potentially applicable as a functional monomer for bonding metals and alloys.
著者
Shunsuke AKAHANE Hiroyasu KOIZUMI Akihisa KODAIRA Mitsuo NAKAMURA Takayuki YONEYAMA Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2019-159, (Released:2020-05-12)
参考文献数
23

The purpose of this study is to investigate the combined effect of two-liquid silane-phosphate primer and single-liquid sodium sulfite primer on bonding between self-polymerizing resins and feldspathic ceramics, and to promote the polymerization behavior of self-polymerizing resins at the bonding interface. The silane-phosphate primer (Super-Bond PZ Primer; PZ) and the sodium sulfite primer (Teeth Primer; TP) were used as the surface treatment agents for bonding the feldspathic ceramics and the self-polymerizing resins (MMA-TBB resin and 4-META/MMA-TBB resin). Combined PZ and TP showed high shear bond strengths. The peak of the differential scanning calorimetry curve was shown to occur early through the addition of TP. These results indicated that additional TP promoted the conversion in the initial polymerization of resin, and the firmly bond was obtained at the interface. PZ+TP treatment can be regarded as an effective treatment for a temporary splint used in teeth restoration.
著者
Kentaro Okamura Hiroyasu Koizumi Akihisa Kodaira Hiroshi Nogawa Takayuki Yoneyama
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.61, no.2, pp.358-363, 2019 (Released:2019-06-18)
参考文献数
21
被引用文献数
8

The purpose of this study was to evaluate the surface properties and gloss of CAD/CAM composites after toothbrush abrasion testing. Four CAD/CAM composites for molars (Cerasmart 300, Estelite P block, Katana Avencia P block, and KZR-CAD HR3 Gammatheta), one CAD/CAM composite for premolars (Shofu Block HC Hard), and one feldspathic ceramics (Vitablocs Mark II) were assessed. Knoop hardness number, gloss, and surface roughness (Ra, Rz, and Sa) were measured before and after toothbrush abrasion testing. Knoop hardness number values were in the order Vitablocs Mark II > Katana Avencia P block > Estelite P Block > Shofu Block HC Hard > Cerasmart 300 > KZR-CAD HR3 Gammatheta. After testing, the gloss of Estelite P block and KZR-CAD HR3 Gammatheta was greatly decreased and surface roughness was greatly increased. Periodic recall and re-polishing may thus be necessary when these products are used clinically.
著者
Nobutaka AKAZAWA Hiroyasu KOIZUMI Hiroshi NOGAWA Akihisa KODAIRA Michael F. BURROW Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2018-152, (Released:2019-05-09)
参考文献数
28
被引用文献数
8

The purpose of the current study was to evaluate the effect of etching with potassium hydrogen difluoride (KHF2) and ammonium hydrogen difluoride (NH4HF2) on the bond strength of a self-polymerizing methyl methacrylate resin (MMA-TBB) bonded to zirconia. Zirconia disks were prepared using the following surface treatment: no treatment, alumina blasting, and etching with KHF2 or NH4HF2. The specimens were bonded with the MMA-TBB. The shear bond (Ø=5 mm) strength was measured. The surface free energies of the specimens were determined by measuring contact angles. The KHF2 and NH4HF2 groups exhibited higher shear bond strength and surface free energy than did the alumina blasting and no treatment groups. Compared with alumina blasting, etching with KHF2 and NH4HF2 exhibited superior bonding ability of mechanical retention to zirconia.
著者
Hideyuki Imai Hiroyasu Koizumi Akihisa Kodaira Kentaro Okamura Shunsuke Akahane Hideo Matsumura
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.61, no.1, pp.178-183, 2019 (Released:2019-03-28)
参考文献数
16
被引用文献数
1

This study evaluated the light intensity of light-emitting diode (LED) units and the effects of five laboratory polymerization units on hardness and flexural strength. Two indirect composite materials (Cesead N and Solidex Hardura) were polymerized with five units (α-Light II, Hyper LII, LED Cure Master, Twinkle LED, and α-Light V). The light intensity of the devices was measured with a spectroradiometer. After light exposure, Knoop hardness number, flexural strength, and elastic modulus were determined. Evaluation of light intensity, using a wavelength range of 400 to 500 nm, revealed that the α-Light V and Hyper LII units had the highest light intensity. For the top surface of the two composites, the Knoop hardness number was significantly higher for the α-Light V and Hyper LII. For the two composite materials, flexural strength did not differ among the five polymerizing units. The present results indicate that the Cesead N and Solidex Hardura composites can be adequately polymerized with laboratory LED units.
著者
Tomoyo OKAZAKI Hiroyasu KOIZUMI Hiroshi NOGAWA Akihisa KODAIRA Tomotaro NIHEI Hideo MATSUMURA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2017-183, (Released:2018-01-26)
参考文献数
33
被引用文献数
1

This study aimed to investigate how different compositions of experimental silane-based primers in a methyl methacrylate solution containing 3-(trimethoxysilyl)propyl methacrylate (3-TMSPMA) or 3-(4-methacryloyloxyphenyl)propyl trimethoxysilane (3-MPPTS) might act as silicon dioxide bonding agents. With or without post-silanization heat treatment, primer-treated quartz discs were bonded using the MMA-TBB resin and their bond strengths were evaluated. The disks were primed with one of the following materials: 1 mol% 3-TMSPMA, 2 mol% 3-TMSPMA, 1 mol% 3-MPPTS, and 2 mol% 3-MPPTS. Shear bond strength was determined both before and after thermocycling. Statistical analyses were performed with non-parametric procedure (Kruskal-Wallis, Mann-Whitney U, and Steel-Dwass tests). Both primers were effective with heat treatment to enhance bonding between quartz and the MMA-TBB, and the bonding durability of the 1 and 2 mol% 3-MPPTS (16.8 and 24.9 MPa) with heat groups was significantly higher than in the 1 and 2 mol% 3-TMSPMA (5.4 and 9.8 MPa) with heat groups.
著者
Osamu Saiki Hiroyasu Koizumi Nobutaka Akazawa Akihisa Kodaira Kentaro Okamura Hideo Matsumura
出版者
日本大学歯学部
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.58, no.1, pp.117-123, 2016 (Released:2016-03-26)
参考文献数
20
被引用文献数
12

This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016)