著者
Mika Furuchi Momoko Shimada Haruto Hiraba Akihisa Kodaira Akiko Hashiguchi Atsushi Kamimoto
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.21-0224, (Released:2021-06-18)
参考文献数
23

Purpose: To evaluate the influence of polymerization methods and a metal priming agent on the bond strength between gold alloy for metal ceramic restorations and dual-cure-type resin luting agents, and on the strength and hardness of the luting agents.Methods: A total of 154 disks cast by a gold alloy were treated with or without a metal priming agent. One of the three luting agents was applied on the disk. The luting agent was either chemically or dual-polymerized. The shear bond strength was measured both before and after thermocycling. In addition, scanning electron microscope (SEM) observation, flexural strength test, and Knoop hardness test were performed.Results: Significant differences among the luting agents were observed in terms of bond strength and flexural strength. Significant differences between chemically and dual-polymerized luting agents were observed regarding shear bond strength, flexural strength, and Knoop hardness before thermocycling. The application of the priming agent was effective only for a luting agent.Conclusion: Both bond strength and flexural strength differed among three luting agents. The effect of the priming agent on bond strength differed among the luting agents. Both the bond and flexural strength of a chemically polymerized luting agent differed before or after thermocycling.
著者
Futoshi KOMINE Shingo KAMIO Hiroki TAKATA Shogo YAGAWA Serina TAGUCHI Kohei TAGUCHI Akiko HASHIGUCHI Hideo MATSUMURA
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2017-057, (Released:2017-09-07)
参考文献数
41
被引用文献数
3

This study evaluated the effect of zirconia framework design on fracture load of implant-supported zirconia-based prostheses after thermal cycling and mechanical loading. Three different zirconia framework designs were investigated: uniform-thickness (UNI), anatomic (ANA), and supported anatomic (SUP) designs. Each framework was layered with feldspathic porcelain (ZAC group) or indirect composite material (ZIC group). The specimens then underwent fracture load testing after thermal cycling and cyclic loading. In the ZAC group, mean fracture load was significantly lower for UNI design specimens than for the other framework designs. In the ZIC group, there was no significant difference in mean fracture load between ANA design specimens and either UNI or SUP design specimens. To improve fracture resistance of implant-supported zirconia-based prostheses after artificial aging, uniformly thick layering material and appropriate lingual support with zirconia frameworks should be provided.