著者
Hidehiro Iwakawa Masateru Takigawa Junji Yamaguchi Claire A Martin Masahiko Goya Tasuku Yamamoto Miki Amemiya Takashi Ikenouchi Miho Negishi Iwanari Kawamura Kentaro Goto Takatoshi Shigeta Takuro Nishimura Tomomasa Takamiya Susumu Tao Shinsuke Miyazaki Hiroyuki Watanabe Tetsuo Sasano
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0574, (Released:2023-10-27)
参考文献数
28
被引用文献数
1

Background: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30–50 W), contact force (10 g and 20 g), duration (10–60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation.Conclusions: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.
著者
Masateru Takigawa Atsushi Takahashi Taishi Kuwahara Yoshihide Takahashi Kenji Okubo Emiko Nakashima Yuji Watari Jun Nakajima Katsumasa Takagi Kazuya Yamao Tadashi Fujino Tomoyo Sugiyama Shigeki Kimura Hiroyuki Hikita Takashi Irioka Kenzo Hirao Mitsuaki Isobe
出版者
日本循環器学会
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-14-0525, (Released:2014-08-21)
参考文献数
22
被引用文献数
2 6

Background:The aim of this study was to investigate the incidence and predictors (which have not previously been fully elucidated) of late-phase thromboembolism (TE) after catheter ablation (CA) for paroxysmal atrial fibrillation (AF).Methods and Results:We studied 1,156 consecutive patients (61±10 years; 891 men; CHADS2score, 0.8±1.0) after CA for symptomatic paroxysmal AF and examined the details of late-phase TE. During a follow-up of 49.5±21.9 months (median, 47 months; range, 6–113 months) after CA, 9 patients (0.78%) developed late-phase TE, all of which were ischemic stroke. Of these, 5 patients with AF recurrence experienced cardioembolism; the AF was asymptomatic at recurrence. The remaining 4 without AF recurrence experienced cardioembolism (n=1), small-vessel occlusion (n=1), large-artery atherosclerosis (n=1), and stroke of other determined etiology (n=1). On Kaplan-Meier analysis patients with structural heart disease (P=0.003), AF recurrence after the final CA (P=0.01), prior stroke (P=0.002), CHADS2score ≥2 (P=0.0002), left ventricular ejection fraction <50% (P<0.0001), and spontaneous echo contrast on transesophageal echocardiogram (P=0.0004) had a significantly higher risk of late-phase TE. Multivariate analysis indicated that CHADS2score ≥2 (HR, 4.49; 95% CI: 1.08–22.56; P=0.04) independently predicted late-phase TE.Conclusions:The incidence of TE was low after CA for paroxysmal AF, but CHADS2score ≥2 independently increased the risk of late-phase TE.