著者
Hidehiro Iwakawa Masateru Takigawa Junji Yamaguchi Claire A Martin Masahiko Goya Tasuku Yamamoto Miki Amemiya Takashi Ikenouchi Miho Negishi Iwanari Kawamura Kentaro Goto Takatoshi Shigeta Takuro Nishimura Tomomasa Takamiya Susumu Tao Shinsuke Miyazaki Hiroyuki Watanabe Tetsuo Sasano
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0574, (Released:2023-10-27)
参考文献数
28
被引用文献数
1

Background: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30–50 W), contact force (10 g and 20 g), duration (10–60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation.Conclusions: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.
著者
Mihoko Kawabata Masahiko Goya Takeshi Sasaki Shingo Maeda Yasuhiro Shirai Takuro Nishimura Takakatsu Yoshitake Shinya Shiohira Mitsuaki Isobe Kenzo Hirao
出版者
日本循環器学会
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-16-1089, (Released:2017-02-07)
参考文献数
22
被引用文献数
37

Background:Atrial fibrillation (AF) is a common cardiac arrhythmia, associated with increased cardiovascular morbidity and mortality including thromboembolic events. The aims of this study were to assess the prevalence of left atrial appendage (LAA) thrombi in Japanese non-valvular atrial fibrillation (NVAF) patients undergoing preprocedural transesophageal echocardiography (TEE) during anticoagulation therapy, and to compare the efficacy of warfarin and direct oral anticoagulants (DOAC).Methods and Results:This retrospective study reviewed records of 559 consecutive NVAF patients (445 men; age, 62±11 years) undergoing preprocedural TEE following at least 3 weeks of anticoagulation therapy. Of these, 275 patients had non-paroxysmal AF (49%). LAA thrombus was observed in 15 patients (2.7%). The prevalence of LAA thrombi was similar between the DOAC group (2.6%) and the warfarin group (2.8%, P=0.86). No patients with CHA2DS2-VASc score=0, or paroxysmal AF without prior stroke or transient ischemic attack, had LAA thrombi. On univariate analysis, non-paroxysmal AF, structural heart disease, antiplatelet therapy, larger left atrium, higher brain natriuretic peptide (BNP), reduced LAA flow, and higher CHA2DS2-VASc score were all associated with LAA thrombi. On multivariate analysis, BNP ≥173 pg/mL remained the only independent predictor of LAA thrombi.Conclusions:LAA thrombi were found in 2.7% of Japanese NVAF patients scheduled for procedures despite ongoing oral anticoagulation therapy. Incidence of thrombi was similar for patients on DOAC and on warfarin.