著者
Hidehiro Iwakawa Masateru Takigawa Junji Yamaguchi Claire A Martin Masahiko Goya Tasuku Yamamoto Miki Amemiya Takashi Ikenouchi Miho Negishi Iwanari Kawamura Kentaro Goto Takatoshi Shigeta Takuro Nishimura Tomomasa Takamiya Susumu Tao Shinsuke Miyazaki Hiroyuki Watanabe Tetsuo Sasano
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0574, (Released:2023-10-27)
参考文献数
28
被引用文献数
1

Background: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30–50 W), contact force (10 g and 20 g), duration (10–60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation.Conclusions: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.
著者
Tatsuhiko Hirao Yasuteru Yamauchi Rena Nakamura Takatoshi Shigeta Hiroshi Yoshida Shinichi Tachibana Atsuhito Oda Aki Ito Mitsutoshi Asano Hidetoshi Suzuki Tsukasa Shimura Manabu Kurabayashi Masahiko Goya Kaoru Okishige Tetsuo Sasano
出版者
International Heart Journal Association
雑誌
International Heart Journal (ISSN:13492365)
巻号頁・発行日
vol.62, no.2, pp.320-328, 2021-03-30 (Released:2021-03-30)
参考文献数
24

Second-generation cryoballoon (CB) ablation is effective in achieving pulmonary vein (PV) isolation (PVI) in atrial fibrillation (AF) patients. The "crosstalk" (CST) phenomenon has been reported to reduce unnecessary applications during CB ablation. Nevertheless, it is unclear under what conditions the CST phenomenon occurs.To seek the predictors of the CST phenomenon during CB-guided PVI, CST phenomenon in achieving ipsilateral superior PVI during inferior PV ablation was analyzed in AF patients who underwent de novo ablation using CB. CB occlusion status and nadir balloon temperature (NT) were compared in these patients, and all ablated superior PVs were categorized into three groups according to the necessity of the touch up ablation and effectiveness of the phenomenon.Of 1082 superior PVs, 16, 40, and 1026 were classified into the CST success, CST failure, and control groups (unnecessary CST), respectively. The proportion of superior PVs ablated with complete occlusion using the CB was significantly higher in the CST success group than in the other two groups. The proportion of superior PVs ablated with NT ≤ −46°C was higher in the CST success group than in the CST failure group. The CST phenomenon was always observed if CB ablation of the superior PVs was performed with both complete occlusion and NT ≤ −46°C and was almost always ineffective if it did not meet these two criteria (sensitivity, 100%; specificity, 93%).Successful CST ablation was highly predicted if complete PV occlusion and NT ≤ −46°C during CB ablation of the superior PVs were achieved.