著者
Hidehiro Iwakawa Masateru Takigawa Junji Yamaguchi Claire A Martin Masahiko Goya Tasuku Yamamoto Miki Amemiya Takashi Ikenouchi Miho Negishi Iwanari Kawamura Kentaro Goto Takatoshi Shigeta Takuro Nishimura Tomomasa Takamiya Susumu Tao Shinsuke Miyazaki Hiroyuki Watanabe Tetsuo Sasano
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0574, (Released:2023-10-27)
参考文献数
28
被引用文献数
1

Background: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30–50 W), contact force (10 g and 20 g), duration (10–60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation.Conclusions: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.
著者
Kanae Hasegawa Hiroyasu Uzui Yoshitomo Fukuoka Dai Miyanaga Yuichiro Shiomi Naoto Tama Hiroyuki Ikeda Kentaro Ishida Shinsuke Miyazaki Yoshiki Sekijima Hironobu Naiki Hiroshi Tada
出版者
International Heart Journal Association
雑誌
International Heart Journal (ISSN:13492365)
巻号頁・発行日
vol.63, no.1, pp.49-55, 2022-01-29 (Released:2022-01-29)
参考文献数
29
被引用文献数
2

The diagnosis of cardiac amyloidosis is frequently delayed because histological confirmation is often challenging. Few studies have attempted to clarify the utility and safety of abdominal fat pad fine-needle aspiration (FPFNA) for an initial screening test in patients with suspected cardiac amyloidosis.This study included 77 consecutive patients with suspected non-ischemic cardiomyopathy who had left ventricular dysfunction and/or hypertrophy. All patients underwent abdominal FPFNA and an endomyocardial biopsy. In all patients, the abdominal FPFNA could be performed within less than 5 minutes with no complications; however, in 1 patient (1.3%), the obtained specimen was too small to evaluate. Among the remaining 76 patients, 5 (6.6%) were positive for amyloid (FPFNA[+]) and 7 (9.2%), including the 5 FPFNA[+], were diagnosed with cardiac amyloidosis (AL = 1, ATTR = 6) by endomyocardial biopsy. Positive abdominal FPFNAs indicated cardiac amyloidosis with high accuracy (sensitivity, 71.4%; specificity, 100%).Positive abdominal FPFNAs are directly linked to diagnoses of cardiac amyloidosis. Abdominal FPFNA is simple and useful for the initial screening test for cardiac amyloidosis in patients with non-ischemic cardiomyopathy.