著者
赤林 伸一 有波 裕貴
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 令和2年度大会(オンライン)学術講演論文集 第7巻 空気質 編 (ISSN:18803806)
巻号頁・発行日
pp.13-16, 2020 (Released:2021-10-28)

本報では、CFD 解析(RANS) を用いて、市街地屋外での喫煙時に生じる汚染質濃度分布及び屋内の喫煙所において喫煙者が退出する際のタバコ煙の拡散状況を解析し、建築・都市空間において受動喫煙が発生するリスクを明らかとする。今後の受動喫煙防止政策の策定や適切な分煙手法などに関する基礎的な資料を得ることを目的とする。
著者
文 欣 潔 赤林 伸一 坂口 淳 有波 裕貴
出版者
日本建築学会
雑誌
日本建築学会環境系論文集 (ISSN:13480685)
巻号頁・発行日
vol.82, no.740, pp.873-882, 2017 (Released:2017-10-30)
参考文献数
16
被引用文献数
1 2

INTRODUCTION As the Coefficient of Performance (COP) of heat pump devices varies significantly according to the heating and cooling load and ambient temperature, when selecting a suitable device, it is very important to consider the thermal performance of the house and the local weather conditions. It is common to select a home-use air conditioners according to the room floorage in Japan. The heating and cooling load value per unit floorage from 1964 has not been revised, and is still used in the case of the present air-conditioner selection (maximum heating load per floorage: 275 W/m2). However, this is not the best method for highly insulated houses and leads to problems for energy conservation. In this study, we developed a calorie meter to carry out temperature adjustment, and used it in analysis of the relationships among COP, heating and cooling load and outside air temperature. COP Matrix is constructed by a database of the measurement results. Furthermore, heat load calculation was performed using the insulation efficiency and the local condition of detached housing as analysis variables. As a result of the heat load calculation, Annual Performance Factor (APF) in actual environmental conditions is computed through correlation with the created COP Matrix. The APF calculated from experiment results is compared with the catalogue APF in order to clarify the characteristics of home-use air-conditioners considering the local conditions and heat load conditions. RESEARCH METHODS The indoor chamber of the calorie meter is 3 m wide, 3 m deep, and 2.7 m high. The outdoor chamber is 2 m wide, 2 m deep, and 2 m high. One temperature and humidity sensor and one thermistor anemometer are installed in the inlet of the inside air conditioner unit. Two temperature-and-humidity sensors are installed in the outlet of the inside air conditioner unit. One temperature-and-humidity sensors are installed in the inlet of the outside air conditioner unit, the temperature at this point is the outside temperature. Furthermore, in order to examine experimental accuracy, two thermocouples are separately installed in the inlet and three thermocouples are separately installed in the outlet of the inside air conditioner unit. A COP matrix is created from the relationship of COP, heating and cooling load and outside air temperature. In order to consider the change of APF calculated from experiment results, analysis was performed by changing the insulation efficiency according to the Standard Model issued by the Architectural Institute of Japan (AIJ). We used the meteorological data of the AIJ extended AMeDAS meteorological data. Analysis was performed by heat load simulation software TRNSYS. COP was calculated by collation with the computed COP matrix. RESULTS The COP of cooling is lower when output is relatively low. The COP of heating is higher when the outdoor air temperature is relatively high. And there is a tendency for COP to rise as the flow rate of the inside unit increases. COP matrix in automatic flow rate is similar to COP matrix in relatively small flow rate. Although the APF of an air conditioner in the catalogue is 5.6, which computed from COP matrix in case1-1 (Tokyo) is 2.9, which is about 0.5 times rather than catalogue value. The year cumulative power consumption in the catalogue is about 2,000 kWh, which computed from COP by the COP matrix in case1-1 (Tokyo) is about 3,200kWh, which is about 1.6 times rather than catalogue value. The APF of heating and cooling become lower when insulation efficiency is relatively high. Because the heating load and cooling load is reduced, the frequency of the ON-OFF operation which COP is relatively low is increased.
著者
有波 裕貴 赤林 伸一 坂口 淳
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 (ISSN:18803806)
巻号頁・発行日
vol.2018, pp.81-84, 2018

<p>本報では沖縄電力を除く一般電気事業者9社を対象として発電設備構成と電気料金プランを調査する。それぞれの一般電気事業者の発電構成と供給電力量から時刻別一次エネルギー消費原単位の算出を行う。原発稼働時及び停止時の一次エネルギー消費原単位と電気料金の分析を行い、昼間・夜間電力の利用による一次エネルギー削減効果及び金銭的インセンティブの妥当性の検討を行う。</p>