Multichannel heart motion sensors using flexible circuits were fabricated for the monitoring the heart motion in the heart diseases. In this study, the PVDF sensors were used as the heart motion sensors. These sensors were modified with the air gap and the protection sheet, and the sensors with the flattest frequency response were selected. These selected modified sensors were preliminary used in a 4-channel sensor array in order to check whether the heart sounds were detected, and they precisely detected the motion of S1 and S2. Furthermore, 80 sensors were used for the multichannel sensor array using the flexible printed circuits. By using this 80-channel sensors array, the vibrations of the chest surface were measured and analyzed. As a result, this multichannel sensor array could measure the heart sound and detected a sound distribution of the chest surface. It was concluded that our developed measurement system could be applied to inspect heart diseases employing a digital database management of the auscultation examination.
著者
金森 一紀 魚谷 浩平 高倉 文嗣 西岡 真二 越野 健 藤村 政樹 中積 泰人 岡藤 和博 松田 保 上尾 友美恵 柴山 正美 川井 清
出版者
The Japanese Respiratory Society
雑誌
日本胸部疾患学会雑誌 (ISSN:03011542)
巻号頁・発行日
vol.24, no.9, pp.970-976, 1986-09-25 (Released:2010-02-23)
参考文献数
24

健常者および非発作期の気管支喘息患者を対象に深吸気の影響を検討した. Maximum expiratory flow-volume curve のV25をMEF25, これと同一肺気量における partial expiratory flow-volume curve のVをPEF25とし, Deep Inspimtion (DI) Index=(PEF25-MEF25)/PEF25を求めた. 健常者では若年者の DI Index は負となり深呼吸による気道拡張効果が認められたが, この効果は加齢とともに減弱し, 50歳以上では DI Index は正の値になった. 抗コリン剤吸入後には DI Index は有意に増加して正の値となり年齢差は認められなくなったことから, 若年者では迷走神経の緊張が強く気道の resting tone が収縮性に保たれていることが推測された. 気管支喘息のうち40歳未満で%FEV1.0≧70%の患者では DI Index は負となり, 抗コリン剤吸入後には有意に増加して年の値となったことから, 気管支喘息でも深呼吸の気道拡張効果は存在し迷走神経が関与していると考えられた.