In hospitals oil based ink is occasionally used to write the patient's name, his room number, and names of the drugs that are used in a mixture on the plastic containers used for infusion. This is done to prevent medication errors. In the current study, the effect of an oil-based ink on the infusion fluid was investigated.Using an oil-based ink containing xylene, letters and other characters were written on an infusion fluid container that was made of Polypropylene·Polyethylene·Ethylene vinyl acetate. It was confirmed that some xylene had been transported to the interior of the container (air phase). Furthermore, the xylene concentration in the air phase rose with repetitive writing and erasing, using the same oil-based ink. But no xylene was dissolved in the solution that was in the container (liquid phase).This observation convinced us that it is highly unlikely that the xylene in the ink can be infused directly into a patient's body. However, to assure the quality of the medication that is in liquid form, it is not desirable for a substance that does not normally exist as a component of the medication to move through its container. In the present experiment, physiological saline was used as a solution (liquid phase). Our findings showed that xylene had a high possibility of dissolving in solutions known for high xylene solubility (e. g., solutions with a large amount of amino acids or surfactants). Therefore, it is necessary to design a method to prevent ink from entering a container when an oil-based ink is applied to the outside of it.
著者
濃沼 政美 瀬尾 誠 高瀬 知永 西澤 光代 平野 公晟 荒川 秀俊 前田 昌子
出版者
日本医療薬学会
雑誌
医療薬学 (ISSN:1346342X)
巻号頁・発行日
vol.29, no.2, pp.203-209, 2003-04-10
参考文献数
11
被引用文献数
2

In hospitals oil-based ink is occasionally used to write the patient's name, his room number, and names of the drugs that are used in a mixture on the plastic containers used for infusion. This is done to prevent medication errors. In the current study, the effect of an oil-based ink on the infusion fluid was investigated. Using an oil-bused ink containing xylene, letters and other characters were written on an infusion fluid container that was made of Polypropylene・Polyethylene・Ethylene vinyl acetate. It was confirmed that some xylene had been transported to the interior of the container (air phase). Furthermore, the xylene concentration in the air phase rose with repetitive writing and erasing, using the same oil-based ink. But no xylene was dissolved in the solution that was in the container (Iiquid phase). This observation convinced us that it is highly unlikely that the xylene in the ink can be infused directly into a patient's body. However, to assure the quality of the medication that is in liquid form, it is not desirable for a substance that does not normally exist as a component of the medication to move through its container. In the present experiment, physiological saline was used as a solution (liquid phase). Our findings showed that xylene had a high possibility of dissolving in solutions known for high xylene solubility (e.g., solutions with a large amount of amino acids or surfactants). Therefore, it is necessary to design a method to prevent ink from centering a container when an oil-based ink is applied to the outside of it.
著者
濃沼 政美 西澤 光代 瀬尾 誠 高瀬 知永 平野 公晟 伊藤 克敏 荒川 秀俊 前田 昌子
出版者
一般社団法人日本医療薬学会
雑誌
医療薬学 (ISSN:1346342X)
巻号頁・発行日
vol.28, no.6, pp.541-550, 2002-12-10 (Released:2011-03-04)
参考文献数
5

The most important aspect of an indwelling inter vascular catheters is to maintain the patency of the catheter. We recently developed a Heparin Lock Flush Solution Kit for use with center vein catheters (only in use at our Hospital). The kit consists of a syringe filled with 9 mL of normal saline (NS) and 1 mL of heparin (1000 IU/mL). We performed the following tests to evaluate the stability, sterility, seal, and dust identification in the preparation. The stability and sterility data indicated that heparin maintained its potency and had no bacterial contamination for 3 months. Testing the seal of the syringe indicated that the seal remained patent at a temperature range of 5°C to 60°C. We also found that even if we sterilized a syringe made of polypropylene using ethylene oxide gas (EOG), no toxins (i.e., ethylene oxide, ethylene chlorohydrin, ethylene glycol) were produced. Next, we examined the preparation time and cost to evaluate the practical benefit of developing the kit. According to our results, the estimated preparation time and cost were 43% and 29% less than for previous methods, respectively. Finally, we put a label on the medicine kit to prevent any misuse by the medical staff.
著者
三留 真珠美 伊藤 克敏 荒川 秀俊 前田 昌子
出版者
公益社団法人日本分析化学会
雑誌
分析化学 (ISSN:05251931)
巻号頁・発行日
vol.49, no.6, pp.355-361, 2000-06-05
被引用文献数
2 3

先天性代謝異常症であるフェニルケトン尿症,メイプルシロップ尿症及びガラクトース血症の診断の指標となる血液中フェニルアラニン(Phe),ロイシン(Leu)及びガラクトース(Gal)を迅速かつ簡便に定量することを目的として,固定化酵素カラムを用いるセミミクロFIAによる3成分同時定量法の検討を行った。本法は試料量20μl,分析時間17分間で3成分同時に定量可能であった。本法を先天性代謝異常症スクリーニング用血液濾紙ディスクの測定に応用したところ,それぞれの検量域は0.3~19.6(Phe),0.8~18.4(Leu),0.4~18.2(Gal)mg/dlであり,現在マススクリーニングで行われているカットオフレベルを十分カバーできた。日内変動は標準血液濾紙の各ポイントにおいていずれも2.4%(RSD,n=5)以下と良好であった。また,ヒト成人血液を用いて調製した血液濾紙からの平均添加回収率はPhe,Leu,Galそれぞれ,77.4,78.5,97.4%(n=11)であった。本法を用い正常新生児血液濾紙の測定を行ったところ,その平均血中濃度(n=30)はそれぞれ1.5(Phe),2.4(Leu),2.6(Gal)mg/dlであった。
著者
田村 善蔵 森岡 朋子 前田 昌子 辻 章夫
出版者
公益社団法人日本分析化学会
雑誌
分析化学 (ISSN:05251931)
巻号頁・発行日
vol.43, no.4, pp.339-346, 1994-04-05
被引用文献数
5 24

フルオレセイン(F)とスルホンフルオレセイン(SF)のpH0からpH10までの5×10^<-6>M水溶液の吸収スペクトルを解析した.SFはH_2SF, HSF^-及びSF^<2->からなり, 酸HAの解離定数をK_a=α_<H+>[A^-]/[HA]とするとき等吸収点の波長における吸光度からpK_<a1>=3.10,pK_<a2>=6.25であることが分かり, さらにHSF^-のスペクトルが求められ, 三つの分子種がすべてキノノイド構造をもつと推定された.FはH_3F^+, H_2F, HF^-及びF^<2->からなり, 二つの等吸収点に共通な波長における吸光度からpK_<a2>=4.20であることがわかり, さらに試行錯誤によってHF^-とH_2FのスペクトルならびにpK_<a3>=6.39とpK_<a1>=2.24が求められた.またH_2Fが一つのラクトノイド分子種と二つのキノノイド分子種の10 : 3 : 2の混合物であると推定された.
著者
河本 美津子 荒川 秀俊 前田 昌子 辻 章夫
出版者
公益社団法人日本分析化学会
雑誌
分析化学 (ISSN:05251931)
巻号頁・発行日
vol.40, no.10, pp.537-542, 1991-10-05
被引用文献数
3 1

還元型ニコチンアミドアデニンジヌクレオチド(NADH)を高感度に測定することを目的として酵素サイクリング法によりNADHを増幅させ, 化学発光法で測定する方法を検討した.酵素サイクリングに用いた酵素反応系はリンゴ酸デヒドロゲナーゼ/アルコールデヒドロゲナーゼ系で, 生成したリンゴ酸を過剰量のNADP^+とMalic enzymeによりNADPHとし, 既報の方法に従ってイソルミノール/ミクロペルオキシダーゼによる化学発光法で測定した.最適条件下でのNADHの検量域は0.01〜5pmol/assayで, 酵素サイクリングを用いない既報と比較して約1000倍感度が向上した.本法をアルカリホスファターゼの酵素活性測定に適用したところ0.036〜18amol/assayの検量域で既報と比較して約50倍感度が向上し, その精度は3.9〜6.3%(相対標準偏差)であった.更に本法を17α-ヒドロキシプロゲステロン(競合法)及びヒトじゅう毛性ゴナドトロピン(サンドイッチ法)酵素免疫測定法に応用した.