著者
古川 勉寛 藤原 孝之 上條 正義 村上 裕亮
出版者
Japan Society of Kansei Engineering
雑誌
日本感性工学会論文誌 (ISSN:18845258)
巻号頁・発行日
pp.TJSKE-D-15-00008, (Released:2015-07-24)
参考文献数
32

The objectives of this research are to implement the examination and the analysis of the utterances that accompany movements, and to elucidate whether these utterances are likely to be applied as movement-support technology. In the first phase of the field survey, we studied changes in the rate of vocal output with changes in the height of a platform to stand on; then, in the second phase of the survey, we investigated the influence exerted by vocal output or the absence thereof on walking ease and Maximum Walking Speed (MWS). In the analytical study, we observed excitation levels of spinal motor cells in healthy adults using H-wave. It is suggested by the results that (1) the rate of vocalization changes, (2) MWS is not improved, (3) the ease of walking is affected, and (4) the level of stimulation of spinal cord motor cells is increased.
著者
武田 裕吾 武田 はるか 渡邉 菜月 楊箸 隆哉 古川 勉寛
出版者
日本感性工学会
雑誌
日本感性工学会論文誌 (ISSN:18845258)
巻号頁・発行日
pp.TJSKE-D-20-00005, (Released:2020-11-20)
参考文献数
26
被引用文献数
1

While there are reports on the reliability of the universal goniometer (UG) and smartphone application goniometer (SG), there have been no reports on user impressions when using these devices. In this study, impressions of users of UG and SG that are used in clinical practice were clarified and reliability was compared. Questionnaires on user impressions were administered to 13 staff members who work in the clinical field. Measurements in the hip and knee joints of seven participants were taken by three testers, and intraclass correlation coefficients (ICC) were obtained to assess reliability. Results showed that SG was superior in terms of appearance, weight, texture, portability, usability, versatility and readout. SG was inferior in terms of setting up measurement axes. However, SG demonstrated high reliability even when compared to UG. The intra-and inter-rater ICC were 0.51 to 0.89 and 0.65 to 0.75, respectively.
著者
武田 裕吾 武田 はるか 渡邉 菜月 楊箸 隆哉 古川 勉寛
出版者
日本感性工学会
雑誌
日本感性工学会論文誌
巻号頁・発行日
vol.19, no.4, pp.369-373, 2020
被引用文献数
1

<p>While there are reports on the reliability of the universal goniometer (UG) and smartphone application goniometer (SG), there have been no reports on user impressions when using these devices. In this study, impressions of users of UG and SG that are used in clinical practice were clarified and reliability was compared. Questionnaires on user impressions were administered to 13 staff members who work in the clinical field. Measurements in the hip and knee joints of seven participants were taken by three testers, and intraclass correlation coefficients (ICC) were obtained to assess reliability. Results showed that SG was superior in terms of appearance, weight, texture, portability, usability, versatility and readout. SG was inferior in terms of setting up measurement axes. However, SG demonstrated high reliability even when compared to UG. The intra-and inter-rater ICC were 0.51 to 0.89 and 0.65 to 0.75, respectively.</p>
著者
武田 裕吾 武田 はるか 渡邉 菜月 楊箸 隆哉 古川 勉寛
出版者
日本感性工学会
雑誌
日本感性工学会論文誌 (ISSN:18845258)
巻号頁・発行日
vol.19, no.4, pp.369-373, 2020 (Released:2020-12-25)
参考文献数
26
被引用文献数
1

While there are reports on the reliability of the universal goniometer (UG) and smartphone application goniometer (SG), there have been no reports on user impressions when using these devices. In this study, impressions of users of UG and SG that are used in clinical practice were clarified and reliability was compared. Questionnaires on user impressions were administered to 13 staff members who work in the clinical field. Measurements in the hip and knee joints of seven participants were taken by three testers, and intraclass correlation coefficients (ICC) were obtained to assess reliability. Results showed that SG was superior in terms of appearance, weight, texture, portability, usability, versatility and readout. SG was inferior in terms of setting up measurement axes. However, SG demonstrated high reliability even when compared to UG. The intra-and inter-rater ICC were 0.51 to 0.89 and 0.65 to 0.75, respectively.
著者
古川 勉寛 佐々木 広人 藤原 孝之 小沼 亮
出版者
公益社団法人 日本理学療法士協会 東北ブロック協議会
雑誌
東北理学療法学 (ISSN:09152180)
巻号頁・発行日
vol.29, pp.46-49, 2017-08-31 (Released:2017-09-15)
参考文献数
19
被引用文献数
1

聴覚刺激強度の変化が下肢骨格筋支配の脊髄興奮準位に及ぼす影響を明らかにするために,Hoffman波(以下,H波)を測定した。【方法】:健常成人男性6名(21歳)を対象とした。聴覚刺激は,周波数250Hzの音源を使用して10dBから80dBまで10dB間隔でランダムに刺激した。H波の測定は,右膝窩部から脛骨神経を電気刺激し,同側のヒラメ筋筋腹中央部から導出した。【結果】:H波変化率(%)は,70dBで125%,80dBで142%であった。多重比較検定の結果,10dBと80dB間に有意差が認められた(p<0.05)。
著者
吉崎 邦夫 佐原 亮 遠藤 和博 浜田 純一郎 古川 勉寛 渡邉 哲朗 諸角 一記
出版者
公益社団法人 日本理学療法士協会
雑誌
理学療法学Supplement Vol.43 Suppl. No.2 (第51回日本理学療法学術大会 抄録集)
巻号頁・発行日
pp.0722, 2016 (Released:2016-04-28)

【はじめに,目的】上肢挙上に関する多くの研究は,肩甲骨面において肘関節伸展位で挙上(挙上)している。しかし,日常生活でよくみられる動作は,上肢を肘関節屈曲から伸展しながら挙げる運動(挙手)である。本研究の目的は,挙手における利き手と非利き手間において,肩甲上腕リズム(SHR)と肩甲骨周囲筋の筋活動ついて違いがあるか調査することである。【方法】肩痛の既往がない健常成人 男性15名,平均年齢24歳(19~30歳)を対象とした。体表マーカーは,烏口突起,肩峰角,肩甲棘内縁,上腕骨外側および内側上顆,Th2,Th7及びL5棘突起に挙手動作の中間位で触知し体表に貼付した。測定は,基本的立位姿勢から挙手を利き手と非利き手を自然に3秒間で最大となるように3回試行した。その画像データを三次元動作解析装置で取り込み解析した。筋電図は,三角筋中部線維(DM),僧帽筋上部線維(TU),僧帽筋下部線維(TL)及び前鋸筋下部線維(SA)上の皮膚表面を前処理して表面電極を貼付し,運動中にテレメトリー筋電計を用いて取り込み,三次元動作解析装置と同期した後,多用途生体情報解析システムを用いて解析した。SHRは上腕骨外転角度と肩甲骨上方回旋角度から算出した。筋電図は0度から10度ごとに抽出し,各波形はフィルタ処理,基線算出したのち振幅積分を行い各角度間の筋電図積分値を求めた。4筋の積分筋電図を比較するため,上腕骨外転角度100~110度における4筋の積分値を合計し,各筋の角度間の積分値を除して百分率(%IEMG)で表した。各筋の0度から130度まで10度毎の%IEMGの変化を比較した。統計解析はIBM SPSS Statistics 22を使用し,反復測定の分散分析(P<0.05)を用いた。【結果】挙手動作におけるSHRは,setting phaseとされている0~60度までは不安定で数値が安定せず,また安定した60~130度では利き手側平均3.4非利き手側平均3.2であり有意な差はなかった。筋活動においては,利き手側と非利き手側ではTUに有意な差があり交互作用がみられた。TUの利き手側筋活動は非利き手側に比較して挙手動作の初期から100度まで高く110~130度で逆転して利き手側が高くなる傾向がみられた。DM,TLおよびSAでは有意な差がなかった。【結論】挙手におけるSHRの解析では,利き手側と非利き手側では差がないが,筋活動ではTUは上腕骨外転角度の増加に伴いの%IEMGパターンに差があり交互作用がみられた。従って,挙手動作では,関節可動域の評価において利き手と非利き手または左右の比較を行うことは妥当であることが推察される。しかし,筋活動は,利き手側と非利き手側においてTUに差があっり,一概に両腕を同一とみて比較することはできないことが示唆された。今後は,棘上筋,棘下筋,肩甲下筋,小円筋について調査し,setting phaseと個人差についての詳細な検討が必要である。