著者
田頭 豊 志村 浩孝 坂本 博 佐藤 和宏 梁川 功 千田 浩一
出版者
医用画像情報学会
雑誌
医用画像情報学会雑誌 (ISSN:09101543)
巻号頁・発行日
vol.33, no.2, pp.43-47, 2016-06-27 (Released:2016-07-01)
参考文献数
10

June 7, 2015, Japan Network for Research and Information on Medical Exposures(J-RIME)published Diagnostic Reference Levels(DRLs 2015)for the first time in Japan. To operate the DRL, it is necessary to collect a great deal of radiation dose information of own facilities efficiently. The purpose of this study was to construct a system for collecting dose information in CT examination using Radiation Dose Structured Report(RDSR). As a result of displaying the contents of RDSR using the free software, it was confirmed that there are differences in the information in RDSR by equipment and manufacturers. In-house software of dose management could be designed by focusing on the enumerated value, it was possible to extract information of interest from RDSR. For facilities which cannot introduce a commercial system, development of software for collecting radiation dose information using RDSR contributes greatly to the operation of DRL.
著者
伊藤 大輔 永坂 竜男 梁川 功 吉田 さやか 高瀬 圭
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.64, no.12, pp.1562-1567, 2008-12-20 (Released:2009-01-17)
参考文献数
5
被引用文献数
4 3

We studied the feasibility of high spatial and temporally resolved imaging by a combination of keyhole imaging, which is a fast imaging method, and a 3.0T MRI system which inherently has a high signal-to-noise ratio (SNR). In keyhole imaging, full k-space reference data are collected, followed by repeated dynamic acquisition of the central low-frequency data alone, and this makes dynamic acquisition faster. The purpose of our article is to describe the effects of the reference data on the reconstructed dynamic images with the assumption of vessel visualization. For efficient use of keyhole imaging, it is important to optimize the keyhole percentage and timing of reference data acquisition for the object of interest.
著者
粟井一夫 浅田 朋宏 天内 廣 梅津 芳幸 水谷 宏 梁川 功 山下 一也 伊知地 宏志
出版者
公益社団法人日本放射線技術学会
雑誌
日放技学誌 (ISSN:03694305)
巻号頁・発行日
vol.48, no.1, pp.83-106, 1992
被引用文献数
3

これは過去1年間におけるX線映画領域でのセンシトメトリー班の活動報告である.第47回総会において, その活動報告および公開討論会を行った.そこでの会員からの意見と助言は, この報告書を作成するにあたって参考にさせていただいた.施設間で同じ結果を得ることは, 現在の現場の状況を考慮するとなかなか難しいものがある.そのような状況で少しでも正確な結果を得るためにはどうすべきかを第一番に考えてこのような標準化をはかった.正確な特性曲線作成には現像処理系および濃度測定が大きな影響を及ぼしている.センシトメトリーの標準化をはかるにはこの二点の規格化が不可欠である.濃度計に関しては, JIS・IEC委員会「医用X線写真濃度計班」の報告に期待したい.終りに班活動を遂行するにあたり, 終始援助と理解をいただいた各施設の技師長と技師諸兄, そして実験材料を無償で提供していただいた日本コダック(株)および富士メディカル(株)に深謝を表する次第である.また, データ整理にあたり特性曲線プログラムを無償で提供していただいた斉藤誠氏(東京都立池袋保健所)に感謝いたします.