June 7, 2015, Japan Network for Research and Information on Medical Exposures(J-RIME)published Diagnostic Reference Levels(DRLs 2015)for the first time in Japan. To operate the DRL, it is necessary to collect a great deal of radiation dose information of own facilities efficiently. The purpose of this study was to construct a system for collecting dose information in CT examination using Radiation Dose Structured Report(RDSR). As a result of displaying the contents of RDSR using the free software, it was confirmed that there are differences in the information in RDSR by equipment and manufacturers. In-house software of dose management could be designed by focusing on the enumerated value, it was possible to extract information of interest from RDSR. For facilities which cannot introduce a commercial system, development of software for collecting radiation dose information using RDSR contributes greatly to the operation of DRL.
著者
大友 一輝 遠藤 美芽 村林 優樹 安部 圭亮 小野寺 真奈 鈴木 友裕 高橋 拓己 一ツ木 康晶 稲葉 洋平 千田 浩一
出版者
日本放射線安全管理学会
雑誌
日本放射線安全管理学会誌 (ISSN:13471503)
巻号頁・発行日
vol.19, no.1, pp.2-10, 2020 (Released:2020-06-17)
参考文献数
18
被引用文献数
1

Recently, portable radiography has been performed in many facilities. In portable radiography, the distance between the radiological technologist and the patient is often close. Thus, exposure assessment and radiation protection for radiological technologist is important. However, the use status of personal protective equipment and the recognition of exposure differ depending on the facility and the individual. In addition, no detailed survey on the current state of portable radiography has been reported. Therefore, we conducted a questionnaire survey for radiological technologist involved in portable radiography. As the result of the questionnaire survey, it became clear that the protection status of radiological technologists during portable radiography varies depending on the facility, gender, and age. There were some opinions that it was difficult to keep away from the patient during portable radiography. In that case, it is desirable to wear protective equipment such as a protector.
著者
石屋 博樹 千田 浩一 斎 政博 佐藤 弘之 有馬 宏寧 佐々木 正寿
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.49, no.8, 1993

透視条件下において、X線アナライザの管電圧測定値と実測値はほぼ一致した。また、線量率測定に於いて、X線アナライザ2機種共に低い管電圧側で基準線量計の値より低い値を示し、管電圧が高くなる程、基準線量計の値に近づいた。今回の測定では、低い管電圧の時、線量率及び管電圧の測定が不能になったり、線量率の測定値が低くなったりするものもあったが、この原因としてはX線アナライザの測定レンジの下限を越えたためか、又は、検出限界ぎりぎりのところで測定したために起こったものと考えられる。以上より、X線アナライザは、透視条件という低いX線出力下においても、測定レンジの範囲内では充分QCに使用可能であると思われた。
著者
加藤 守 千田 浩一 盛武 敬 小口 靖弘 加賀 勇治 坂本 肇 塚本 篤子 川内 覚 松本 一真 松村 光章 大阪 肇 豊嶋 英仁
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.72, no.1, pp.73-81, 2016
被引用文献数
3

Deterministic effects have been reported in cardiac interventional procedures. To prevent radiation skin injuries in percutaneous coronary intervention (PCI), it is necessary to measure accurate patient entrance skin dose (ESD) and maximum skin absorbed dose (MSD). We measured the MSD on 62 patients in four facilities by using the Chest-RADIREC<sup>Ⓡ</sup> system. The correlation between MSD and fluoroscopic time, dose area product (DAP), and cumulative air kerma (AK) showed good results, with the correlation between MSD and AK being the strongest. The regression lines using MSD as an outcome value (y) and AK as predictor variables (x) was y=1.18x (R<sup>2</sup>=0.787). From the linear regression equation, MSD is estimated to be about 1.18 times that of AK in real time. The Japan diagnostic reference levels (DRLs) 2015 for IVR was established by the use of dose rates using acrylic plates (20- cm thick) at the interventional reference point. Preliminary reference levels proposed by International Atomic Energy Agency (IAEA) were provided using DAP. In this study, AK showed good correlation most of all. Hence we think that Japanese DRLs for IVR should reconsider by clinical patients' exposure dose such as AK.
著者
加藤 守 千田 浩一 盛武 敬 小口 靖弘 加賀 勇治 坂本 肇 塚本 篤子 川内 覚 松本 一真 松村 光章 大阪 肇 土佐 鉃雄
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.70, no.8, pp.814-820, 2014
被引用文献数
1

In recent years, dose justification and optimization have been attempted in percutaneous coronary intervention (PCI); however, deterministic effects have been reported. To prevent radiation skin injuries in PCI, it is necessary to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not yet been established. In this study, we developed a dosimetry gown that can measure the ESD during PCI using multiple radiophotoluminescence dosimeters (RPLDs). The RPLDs were placed into 84 pockets that were sewn into a dosimetry gown. Patients wear the original dosimetry gown during the procedures, after which we obtain accurate ESD measurements. We believe that this method using RPLDs and a newly-designed dosimetry gown provides accurate ESD measurements during PCI. We expect this system to become a standard method for measuring ESD during PCI.
著者
洞口 正之 千田 浩一 山田 章吾 千田 浩一 山田 章吾 中村 正明 佐藤 匡也 加藤 守 稲葉 洋平 田浦 将明
出版者
東北大学
雑誌
基盤研究(C)
巻号頁・発行日
2007

放射線防護衣素材等の基礎検討結果から、散乱X線においては無鉛シートの防護効果比は管電圧60~120kVの条件でほぼ100%であった。つまり直接X線と異なり、管電圧100kVを超えても、無鉛シートの遮蔽率おとび防護効果は、鉛タイプと同等であることを明らかにした。IVR術者被曝の原因は、ほとんどが患者からの散乱X線であり、さらに無鉛タイプは軽量であるので、IVRの術者被曝防護に適している。また初期臨床的検討結果からも、IVR術者防護における無鉛タイプの放射線防護衣(プロテクター)の有用性が確認されつつある