著者
鎌田 紀彦 鈴木 大隆 廣田 誠一
出版者
日本建築学会
雑誌
日本建築学会計画系論文集 (ISSN:13404210)
巻号頁・発行日
vol.63, no.513, pp.39-45, 1998-11-30 (Released:2017-02-02)
参考文献数
4
被引用文献数
1 1

The aim of this study is to determine the criteria for the wall structures in cold region where fibrous thermal insulation materials are used, by measuring the hygrothermal condition of the full size specimen wall which modeling the execution defects of thermal insulation and vapor barrier. From the experiment results, the wall with air convection in the cavity has possibility to make condensation at the bottom of the wall. It is clarified that an attic space, wall cavities and a crawl space must be separated to avoid air flow connections among them. Vapor barrier installed continuously, and ventilated air space are also effective to keep from making condensation in the insulated wall cavity.
著者
鎌田 紀彦
出版者
一般財団法人 住総研
雑誌
住宅総合研究財団研究論文集 (ISSN:18802702)
巻号頁・発行日
vol.37, pp.21-32, 2011 (Released:2018-01-31)

北海道から始まった高断熱住宅は,日本の住宅に大きな影響を及ぼしてきた。しかし,その普及は遅く,日本の住宅におけるエネルギー消費は,増え続けている。そして,住宅の室内環境は,住宅の性能が不十分なため低いレベルにとどまっている。高断熱住宅の技術開発の経緯を振り返り,整理した上で,これからの日本の住宅が 向かうべき方向と具体的な方策について考察する。