著者
Tadatomo Fukushima Masato Fukunaga Akihiro Isotani Miho Nakamura Ko Yamamoto Kenichi Ishizu Takashi Morinaga Shinichi Shirai Kenji Ando
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0553, (Released:2023-11-30)
参考文献数
12

Background: Left atrial appendage closure (LAAC) usually requires contrast medium during the procedure. However, patients with chronic kidney disease (CKD) are at high risk of developing contrast nephropathy. This study aimed to assess the safety and feasibility of zero-contrast LAAC in patients with CKD.Methods and Results: Zero-contrast LAAC was attempted in 15 patients with CKD Stages 3b-5 who were not on hemodialysis. All procedures were performed successfully, without any periprocedural complications. At the 45-day follow-up, no device-related complications or acute kidney disease were observed.Conclusions: The strategy of zero-contrast LAAC in patients with CKD can be an acceptable option.
著者
Hidetoshi Yoshitani Akihiro Isotani Jae-Kwan Song Shinichi Shirai Hiromi Umeda Jeong Yoon Jang Takeshi Onoue Misako Toki Byung-Joo Sun Dae-Hee Kim Nobuyuki Kagiyama Akihiro Hayashida Jong-Min Song Masataka Eto Yosuke Nishimura Kenji Ando Michiya Hanyu Kiyoshi Yoshida Robert A. Levine Yutaka Otsuji
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-18-0390, (Released:2018-08-22)
参考文献数
24
被引用文献数
3

Background: Basal interventricular septum (IVS) hypertrophy (BSH) with reduced basal IVS contraction and IVS-aorta angle is frequently associated with aortic stenosis (AS). BSH shape suggests compression by the longitudinally elongated ascending aorta, causing basal IVS thickening and contractile dysfunction, further suggesting the possibility of aortic wall shortening to improve the BSH. Surgical aortic valve replacement (SAVR), as opposed to transcatheter AVR (TAVR), includes aortic wall shortening by incision and stitching on the wall and may potentially improve BSH. We hypothesized that BSH configuration and its contraction improves after SAVR in patients with AS. Methods and Results: In 32 patients with SAVR and 36 with TAVR for AS, regional wall thickness and systolic contraction (longitudinal strain) of 18 left ventricular (LV) segments, and IVS-aorta angle were measured on echocardiography. After SAVR, basal IVS/average LV wall thickness ratio, basal IVS strain, and IVS-aorta angle significantly improved (1.11±0.24 to 1.06±0.17; −6.2±5.7 to −9.1±5.2%; 115±22 to 123±14°, P<0.001, respectively). Contractile improvement in basal IVS was correlated with pre-SAVR BSH (basal IVS/average LV wall thickness ratio or IVS-aorta angle: r=0.47 and 0.49, P<0.01, respectively). In contrast, BSH indices did not improve after TAVR. Conclusions: In patients with AS, SAVR as opposed to TAVR improves associated BSH and its functional impairment.
著者
Yoichi Takaya Teiji Akagi Hidehiko Hara Hideaki Kanazawa Yuji Ikari Akihiro Isotani Shinichi Shirai Shunsuke Kubo Takao Morikawa Toru Naganuma Mike Saji Shingo Kuwata Go Hiasa Yusuke Watanabe Masahiro Yamawaki Masao Imai Takashi Matsumoto Masanori Yamamoto Tsutomu Murakami Masahiko Asami Isamu Mizote Tsukasa Okai Hiroki Bota Hiroshi Ito
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-22-0048, (Released:2022-04-05)
参考文献数
18
被引用文献数
4

Background: Transcatheter mitral valve repair with the MitraClip system has been established in selected high-risk patients. The MitraClip procedure results in a relatively large iatrogenic atrial septal defect (iASD). This study aimed to investigate the prevalence and clinical course of iASD requiring transcatheter closure following the MitraClip procedure.Methods and Results: This study was conducted at all 59 institutions that perform transcatheter mitral valve repair with the MitraClip system in Japan. The data of patients on whom transcatheter iASD closure was performed were collected. Of the 2,722 patients who underwent the MitraClip procedure, 30 (1%) required transcatheter iASD closure. The maximum iASD size was 9±4 mm (range, 3–18 mm). The common clinical course of transcatheter iASD closure was hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt. Of the 30 patients, 22 (73%) required transcatheter closure within 24 h following the MitraClip procedure, including 12 with hypoxemia and 5 with right-sided heart failure complicated with cardiogenic shock. Of the 5 patients, 2 required mechanical circulatory support devices. Twenty-one patients immediately underwent transcatheter iASD closure, and hemodynamic deteriorations were resolved; however, 1 patient died without having undergone transcatheter closure.Conclusions: Transcatheter iASD closure was required in 1% of patients who underwent the MitraClip procedure. Many of these patients immediately underwent transcatheter iASD closure because of hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt.
著者
Yasuo Tsuru Mizuki Miura Shinichi Shirai Masaomi Hayashi Kenji Taninobu Hiroshi Takiguchi Shinya Ito Mariko Yano Tomohiro Kawaguchi Takashi Morinaga Akihiro Isotani Shinichi Kakumoto Katsuhiro Seo Yoshio Arai Genichi Sakaguchi Kenji Ando
出版者
International Heart Journal Association
雑誌
International Heart Journal (ISSN:13492365)
巻号頁・発行日
pp.18-484, (Released:2019-04-25)
参考文献数
18
被引用文献数
3

Aortic complex rupture is one of the most critical complications associated with transcatheter aortic valve implantation (TAVI). Its incidence is rare, and its mechanism varies by case; therefore, it is difficult to identify the predictors of complex rupture. Herein, we report a clinical case series of aortic complex rupture. Within our cohort, the frequency of complex rupture was 0.8% (4/497 consecutive patients) with an in-hospital mortality of 0. Among these four patients with complex rupture, two underwent emergent thoracotomy and surgical hemostasis without a heart-lung machine and surgical aortic valve replacement, whereas the other two were conservatively managed. The case overview revealed the following similarities: all the patients were elderly, small women; balloon-expandable valves were used; the annulus area was small with heavily calcified leaflet; and aggressive treatment strategy was used (i.e., oversizing and post-dilatation). In such cases, TAVI should be performed with a careful strategy. Once aortic complex rupture occurs, damage can be minimized through cooperation with an institutional heart team and calm management.