著者
Yoichi Takaya Teiji Akagi Hidehiko Hara Hideaki Kanazawa Yuji Ikari Akihiro Isotani Shinichi Shirai Shunsuke Kubo Takao Morikawa Toru Naganuma Mike Saji Shingo Kuwata Go Hiasa Yusuke Watanabe Masahiro Yamawaki Masao Imai Takashi Matsumoto Masanori Yamamoto Tsutomu Murakami Masahiko Asami Isamu Mizote Tsukasa Okai Hiroki Bota Hiroshi Ito
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-22-0048, (Released:2022-04-05)
参考文献数
18
被引用文献数
3

Background: Transcatheter mitral valve repair with the MitraClip system has been established in selected high-risk patients. The MitraClip procedure results in a relatively large iatrogenic atrial septal defect (iASD). This study aimed to investigate the prevalence and clinical course of iASD requiring transcatheter closure following the MitraClip procedure.Methods and Results: This study was conducted at all 59 institutions that perform transcatheter mitral valve repair with the MitraClip system in Japan. The data of patients on whom transcatheter iASD closure was performed were collected. Of the 2,722 patients who underwent the MitraClip procedure, 30 (1%) required transcatheter iASD closure. The maximum iASD size was 9±4 mm (range, 3–18 mm). The common clinical course of transcatheter iASD closure was hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt. Of the 30 patients, 22 (73%) required transcatheter closure within 24 h following the MitraClip procedure, including 12 with hypoxemia and 5 with right-sided heart failure complicated with cardiogenic shock. Of the 5 patients, 2 required mechanical circulatory support devices. Twenty-one patients immediately underwent transcatheter iASD closure, and hemodynamic deteriorations were resolved; however, 1 patient died without having undergone transcatheter closure.Conclusions: Transcatheter iASD closure was required in 1% of patients who underwent the MitraClip procedure. Many of these patients immediately underwent transcatheter iASD closure because of hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt.
著者
Shigenobu Inami Masamichi Takano Masanori Yamamoto Daisuke Murakami Kenichiro Tajika Kenji Yodogawa Shinya Yokoyama Norihiko Ohno Takayoshi Ohba Junko Sano Chikao Ibuki Yoshihiko Seino Kyoichi Mizuno
出版者
一般社団法人 インターナショナル・ハート・ジャーナル刊行会
雑誌
International Heart Journal (ISSN:13492365)
巻号頁・発行日
vol.48, no.6, pp.725-732, 2007 (Released:2007-12-27)
参考文献数
25
被引用文献数
34 70

It has been reported that green tea consumption reduces the risk of coronary artery disease and cardiac events. Catechin is a major constituent of Japanese green tea and an antioxidant. Lipids and oxidization of low-density lipoprotein cholesterol (LDL-C) play important roles in atherosclerosis. Therefore, we evaluated the effect of catechin intake on the lipid profile and plasma oxidized LDL. The study population consisted of 40 healthy adult volunteers (10 men, 30 women). Catechin was extracted from green tea leaves. The subjects were randomly divided into two groups, a catechin group (n = 29) and a control group (n = 11). In the catechin group, catechin (500 mg: equivalent to 6 or 7 cups of green tea) was administered orally. Venous blood samples were obtained before eating a meal at the start and after 4 weeks without any lifestyle modification. Plasma oxidized LDL assay was performed with a sandwich-type enzyme immunoassay using anti-oxidized phosphatidylcholine monoclonal antibody. The baseline lipid profiles and tea consumptions were similar between the two groups. Plasma oxidized LDL was significantly decreased after catechin administration (from 9.56 ± 9.2 to 7.76 ± 7.7 U/mL, P = 0.005), while plasma LDL-C, triglyceride, and HDL-C concentrations did not change. Catechin decreased the plasma oxidized LDL concentration without significant change in plasma LDL concentration. The mechanism of the beneficial effects of green tea on coronary artery disease might result from a decrease in plasma oxidized LDL.