著者
Yuki Katagiri Kazumasa Yamasaki Noriyuki Hatanaka Hiroki Bota Tomoyuki Tani Tomonori Koga Yuki Setogawa Manabu Misawa Takashi Ueda Seiji Yamazaki
出版者
The Japanese Circulation Society
雑誌
Circulation Reports (ISSN:24340790)
巻号頁・発行日
vol.4, no.6, pp.274-284, 2022-06-10 (Released:2022-06-10)
参考文献数
28
被引用文献数
2

Background: In patients with aortic stenosis (AS), measurement of aortic valve calcification (AVC) using computed tomography (CT) is recommended in cases where echocardiographic measurements are inconclusive. However, sex-specific AVC thresholds proposed in the guidelines for predicting severe AS (women: 1,200 arbitrary units [AU]; men: 2,000 AU) are based on studies from Western countries.Methods and Results: We retrospectively included 512 Japanese patients with at least moderate AS who underwent transthoracic echocardiography and CT. AVC was quantified using the Agatston method. AVC was positively correlated with peak aortic jet velocity and mean transvalvular gradient (mPG), and negatively correlated with aortic valve area (AVA) and the AVA index (AVAi). In 257 patients with concordant AS grading (152 severe AS [AVAi ≤0.6 cm2/m2, mPG ≥40 mmHg], 105 moderate AS [AVAi >0.6 cm2/m2, mPG <40 mmHg]), receiver operating characteristic curve analysis of AVC predicting severe AS yielded an area under the curve of 0.91 (95% confidence interval [CI] 0.87–0.95; P<0.001) in women and 0.86 (95% CI 0.75–0.98; P<0.001) in men. The optimal thresholds (women: 1,379 AU; men: 1,802 AU) were close to those proposed in the guidelines. The diagnostic accuracy of the thresholds in the guidelines was similar to that of the optimal thresholds.Conclusions: The sex-specific AVC thresholds proposed in international guidelines can be applied to Japanese AS patients, yielding similar diagnostic accuracy as the optimal cut-off derived from the study patients.
著者
Yoichi Takaya Teiji Akagi Hidehiko Hara Hideaki Kanazawa Yuji Ikari Akihiro Isotani Shinichi Shirai Shunsuke Kubo Takao Morikawa Toru Naganuma Mike Saji Shingo Kuwata Go Hiasa Yusuke Watanabe Masahiro Yamawaki Masao Imai Takashi Matsumoto Masanori Yamamoto Tsutomu Murakami Masahiko Asami Isamu Mizote Tsukasa Okai Hiroki Bota Hiroshi Ito
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-22-0048, (Released:2022-04-05)
参考文献数
18
被引用文献数
4

Background: Transcatheter mitral valve repair with the MitraClip system has been established in selected high-risk patients. The MitraClip procedure results in a relatively large iatrogenic atrial septal defect (iASD). This study aimed to investigate the prevalence and clinical course of iASD requiring transcatheter closure following the MitraClip procedure.Methods and Results: This study was conducted at all 59 institutions that perform transcatheter mitral valve repair with the MitraClip system in Japan. The data of patients on whom transcatheter iASD closure was performed were collected. Of the 2,722 patients who underwent the MitraClip procedure, 30 (1%) required transcatheter iASD closure. The maximum iASD size was 9±4 mm (range, 3–18 mm). The common clinical course of transcatheter iASD closure was hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt. Of the 30 patients, 22 (73%) required transcatheter closure within 24 h following the MitraClip procedure, including 12 with hypoxemia and 5 with right-sided heart failure complicated with cardiogenic shock. Of the 5 patients, 2 required mechanical circulatory support devices. Twenty-one patients immediately underwent transcatheter iASD closure, and hemodynamic deteriorations were resolved; however, 1 patient died without having undergone transcatheter closure.Conclusions: Transcatheter iASD closure was required in 1% of patients who underwent the MitraClip procedure. Many of these patients immediately underwent transcatheter iASD closure because of hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt.