著者
Takayuki Shimaoka Koji Kumagai Takeshi Katsumi Michio Iba
出版者
The Japanese Geotechnical Society
雑誌
Japanese Geotechnical Society Special Publication (ISSN:21888027)
巻号頁・発行日
vol.2, no.70, pp.2385-2390, 2016-01-31 (Released:2016-01-29)
参考文献数
5

A number of temporary storage sites have been commissioned to contain soils and wastes generated from the decontamination works after the accident at Tokyo Electric Power Company’s Fukushima Dai-ichi Nuclear Power Plant. At these sites, volume reduction has been observed in the flexible container bags caused by the dehydration and decomposition of the decontamination waste inside. This situation leads to uneven settlement of the top of these flexible container bags in these temporary storage sites, and might result in problems such as leakage through top and bottom liners installed to contain these container bags. To deal with these problems immediately, the Geomembrane Technical Committee, Japan Chapter of International Geosynthetics Society has conducted deliberations and made reports on procedures for selection and installation of storage containers that are to prevent polluted water from leaking outside of storage sites, structures, and barrier materials, a new inspection procedure for seaming of cover geomembranes, installation of cover materials that are to counter uneven settlement of soil, and also temperature control procedures to prevent natural ignition of waste. This paper summarizes the deliberations and the procedures adopted.
著者
Toyonobu Tsuda Takeshi Kato Keisuke Usuda Takashi Kusayama Soichiro Usui Kenji Sakata Kenshi Hayashi Masa-aki Kawashiri Masakazu Yamagishi Masayuki Takamura Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Koichi Nagashima Yasuo Okumura on behalf of the AF Ablation Frontier Registry and the Hokuriku-Plus AF Registry Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.87, no.7, pp.939-946, 2023-06-23 (Released:2023-06-23)
参考文献数
36
被引用文献数
5

Background: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13–0.70; P=0.004) than the medical therapy group.Conclusions: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.
著者
Toyonobu Tsuda Takeshi Kato Keisuke Usuda Takashi Kusayama Soichiro Usui Kenji Sakata Kenshi Hayashi Masa-aki Kawashiri Masakazu Yamagishi Masayuki Takamura Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Koichi Nagashima Yasuo Okumura on behalf of the AF Ablation Frontier Registry and the Hokuriku-Plus AF Registry Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-22-0461, (Released:2022-12-02)
参考文献数
36
被引用文献数
5

Background: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13–0.70; P=0.004) than the medical therapy group.Conclusions: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.
著者
Yasuo Okumura Koichi Nagashima Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Takeshi Kato Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari on behalf of the AF Ablation Frontier Registry
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-0602, (Released:2019-10-16)
参考文献数
27
被引用文献数
17

Background:The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status.Conclusions:Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.
著者
Yasuo Okumura Koichi Nagashima Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Takeshi Kato Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari on behalf of the AF Ablation Frontier Registry
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.83, no.12, pp.2418-2427, 2019-11-25 (Released:2019-11-25)
参考文献数
27
被引用文献数
17

Background:The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status.Conclusions:Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.
著者
Kenichi Kaseno Shigeto Naito Kohki Nakamura Tamotsu Sakamoto Takehito Sasaki Naofumi Tsukada Mamoru Hayano Suguru Nishiuchi Etsuko Fuke Yuko Miki Keijiro Nakamura Eiji Yamashita Koji Kumagai Shigeru Oshima Hiroshi Tada
出版者
日本循環器学会
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.76, no.10, pp.2337-2342, 2012 (Released:2012-09-25)
参考文献数
26
被引用文献数
53 73

Background: Periprocedural anticoagulation using uninterrupted warfarin could reduce the risk of thromboembolic complications of atrial fibrillation (AF) ablation. Few studies, however, have evaluated the efficacy and safety of periprocedural dabigatran in AF ablation. Methods and Results: A total of 211 consecutive patients who underwent AF ablation, including 110 patients who received 110mg dabigatran twice daily (group D) and 101 patients who received dose-adjusted warfarin (international normalized ratio, 2.0–3.0; group W), were evaluated. Dabigatran was discontinued on the morning of the procedure, and resumed on the next morning. Warfarin was continued throughout the procedure. During the procedure, heparin infusion was maintained to achieve an activated clotting time of >300s. Postprocedural cerebral magnetic resonance imaging (MRI) was performed in 60 patients (group D, n=31; group W, n=29). No periprocedural deaths or symptomatic thromboembolic complications were observed in either group. MRI indicated a silent cerebral infarction in 1 patient in each group. Five patients in group D and 11 in group W had minor bleeding (P=0.12). Cardiac tamponade occurred in 2 patients in group W, but in none in group D. Total bleeding complications occurred less frequently in group D (4.5%) than in group W (12.9%; P<0.05). Conclusions: Dabigatran at a dose of 110mg twice daily was safe for AF ablation in patients with a relatively low risk of thromboemboli, suggesting that it may become an alternative to warfarin in those patients.  (Circ J 2012; 76: 2337–2342)