著者
Mitsuru Takami Koji Fukuzawa Kunihiko Kiuchi Makoto Takemoto Toshihiro Nakamura Jun Sakai Atsusuke Yatomi Kazutaka Nakasone Yusuke Sonoda Kyoko Yamamoto Hiroyuki Takahara Yuya Suzuki Kenichi Tani Ken-ichi Hirata
出版者
The Japanese Circulation Society
雑誌
Circulation Reports (ISSN:24340790)
巻号頁・発行日
vol.3, no.5, pp.294-299, 2021-05-10 (Released:2021-05-10)
参考文献数
10
被引用文献数
3

Background:Demand is growing for remote electrocardiogram (ECG) monitoring systems in the COVID-19 era in Japan. This study describes initial experiences with a small wireless ECG monitoring device and the utility of delivery via the postal service for outpatient care in Japan.Methods and Results:Long-term ECG monitoring following postal delivery of the small ECG device was evaluated in 25 patients. The patients had no difficulties with either the postal delivery or self-fitting and wearing the devices. A median of 57 h monitoring per patient was performed. Arrhythmic events were detected in 8 patients. Most patients were satisfied with both the ECG devices and postal delivery.Conclusions:Postal delivery of ECG devices could be used in clinical practice to achieve less or no in-person contact during the COVID-19 era.
著者
Mitsuru Takami Koji Fukuzawa Kunihiko Kiuchi Hiroyuki Takahara Kimitake Imamura Toshihiro Nakamura Yusuke Sonoda Kazutaka Nakasone Kyoko Yamamoto Yuya Suzuki Kenichi Tani Hidehiro Iwai Yusuke Nakanishi Mitsuhiko Shoda Atsushi Murakami Shogo Yonehara Ken-ichi Hirata
出版者
The Japanese Circulation Society
雑誌
Circulation Reports (ISSN:24340790)
巻号頁・発行日
pp.CR-23-0083, (Released:2023-10-28)
参考文献数
11

Background: There is a strong demand for remote monitoring systems to gather health data. This study investigated the safety, usefulness, and patient satisfaction in outpatient care using telehealth with real-time electrocardiogram (ECG) monitoring after catheter ablation.Methods and Results: In all, 38 patients who underwent catheter ablation were followed up using telehealth. At the 3- and 6-month follow-up, a self-fitted Duranta ECG monitoring device was sent to the patient’s home before the online consultation. Patients attached the devices themselves, and the doctors viewed the patients by video chat and performed real-time ECG monitoring. The frequency of hospital visits and the ECG monitoring duration were compared with conventional in-person follow-up data (n=102). The completion rate for telehealth follow-up was 32 of 38 patients (84%). The number of hospital visits during the 6 months was significantly lower with telehealth follow-up than with conventional follow-up (median [interquartile range] 1 [1–1] vs. 5 [3–5]; P<0.0001). However, the ECG monitoring duration was approximately 4-fold longer for the telehealth follow-up (median [interquartile range] 89 [64–117] vs. 24 [0.1–24] h; P<0.0001). No major adverse events were observed during the telehealth follow-up. Patient surveys showed high satisfaction with telehealth follow-up due to reduced hospital visits.Conclusions: A combination of telehealth follow-up with real-time ECG monitoring increased the ECG monitoring duration and patient satisfaction without any adverse events.
著者
Toyonobu Tsuda Takeshi Kato Keisuke Usuda Takashi Kusayama Soichiro Usui Kenji Sakata Kenshi Hayashi Masa-aki Kawashiri Masakazu Yamagishi Masayuki Takamura Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Koichi Nagashima Yasuo Okumura on behalf of the AF Ablation Frontier Registry and the Hokuriku-Plus AF Registry Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.87, no.7, pp.939-946, 2023-06-23 (Released:2023-06-23)
参考文献数
36
被引用文献数
5

Background: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13–0.70; P=0.004) than the medical therapy group.Conclusions: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.
著者
Toyonobu Tsuda Takeshi Kato Keisuke Usuda Takashi Kusayama Soichiro Usui Kenji Sakata Kenshi Hayashi Masa-aki Kawashiri Masakazu Yamagishi Masayuki Takamura Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Koichi Nagashima Yasuo Okumura on behalf of the AF Ablation Frontier Registry and the Hokuriku-Plus AF Registry Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-22-0461, (Released:2022-12-02)
参考文献数
36
被引用文献数
5

Background: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13–0.70; P=0.004) than the medical therapy group.Conclusions: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.
著者
Yasuo Okumura Koichi Nagashima Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Takeshi Kato Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari on behalf of the AF Ablation Frontier Registry
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-0602, (Released:2019-10-16)
参考文献数
27
被引用文献数
17

Background:The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status.Conclusions:Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.
著者
Mitsuru Takami Koji Fukuzawa Kunihiko Kiuchi Hiroyuki Takahara Kimitake Imamura Toshihiro Nakamura Yusuke Sonoda Kazutaka Nakasone Kyoko Yamamoto Yuya Suzuki Kenichi Tani Hidehiro Iwai Yusuke Nakanishi Mitsuhiko Shoda Atsushi Murakami Shogo Yonehara Ken-ichi Hirata
出版者
The Japanese Circulation Society
雑誌
Circulation Reports (ISSN:24340790)
巻号頁・発行日
vol.5, no.11, pp.415-423, 2023-11-10 (Released:2023-11-10)
参考文献数
11

Background: There is a strong demand for remote monitoring systems to gather health data. This study investigated the safety, usefulness, and patient satisfaction in outpatient care using telehealth with real-time electrocardiogram (ECG) monitoring after catheter ablation.Methods and Results: In all, 38 patients who underwent catheter ablation were followed up using telehealth. At the 3- and 6-month follow-up, a self-fitted Duranta ECG monitoring device was sent to the patient’s home before the online consultation. Patients attached the devices themselves, and the doctors viewed the patients by video chat and performed real-time ECG monitoring. The frequency of hospital visits and the ECG monitoring duration were compared with conventional in-person follow-up data (n=102). The completion rate for telehealth follow-up was 32 of 38 patients (84%). The number of hospital visits during the 6 months was significantly lower with telehealth follow-up than with conventional follow-up (median [interquartile range] 1 [1–1] vs. 5 [3–5]; P<0.0001). However, the ECG monitoring duration was approximately 4-fold longer for the telehealth follow-up (median [interquartile range] 89 [64–117] vs. 24 [0.1–24] h; P<0.0001). No major adverse events were observed during the telehealth follow-up. Patient surveys showed high satisfaction with telehealth follow-up due to reduced hospital visits.Conclusions: A combination of telehealth follow-up with real-time ECG monitoring increased the ECG monitoring duration and patient satisfaction without any adverse events.
著者
Yasuo Okumura Koichi Nagashima Masaru Arai Ryuta Watanabe Katsuaki Yokoyama Naoya Matsumoto Takayuki Otsuka Shinya Suzuki Akio Hirata Masato Murakami Mitsuru Takami Masaomi Kimura Hidehira Fukaya Shiro Nakahara Takeshi Kato Wataru Shimizu Yu-ki Iwasaki Hiroshi Hayashi Tomoo Harada Ikutaro Nakajima Ken Okumura Junjiroh Koyama Michifumi Tokuda Teiichi Yamane Yukihiko Momiyama Kojiro Tanimoto Kyoko Soejima Noriko Nonoguchi Koichiro Ejima Nobuhisa Hagiwara Masahide Harada Kazumasa Sonoda Masaru Inoue Koji Kumagai Hidemori Hayashi Kazuhiro Satomi Yoshinao Yazaki Yuji Watari on behalf of the AF Ablation Frontier Registry
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.83, no.12, pp.2418-2427, 2019-11-25 (Released:2019-11-25)
参考文献数
27
被引用文献数
17

Background:The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status.Conclusions:Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.