著者
Sachiko Yamaguchi-Sekino Noriko Kojimahara
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.bc.2022-0080, (Released:2022-11-25)
参考文献数
8

The effect of maternal occupational non-ionizing radiation (NIR) exposure from MRI on premature birth and low birth weight delivery was analyzed based on questionnaire survey (263 employees, 443 births). Although the highest occurrence rates of both outcomes were observed in the group whose NIR exposure occurred only before pregnancy, no statistical significance was detected.
著者
Toshiaki Taoka Rintaro Ito Rei Nakamichi Toshiki Nakane Hisashi Kawai Shinji Naganawa
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2022-0012, (Released:2022-11-25)
参考文献数
115
被引用文献数
8

Interest in interstitial fluid dynamics has increased since the proposal of the glymphatic system hypothesis. Abnormal dynamics of the interstitial fluid have been pointed out to be an important factor in various pathological statuses. In this article, we propose the concept of central nervous system interstitial fluidopathy as a disease or condition in which abnormal interstitial fluid dynamics is one of the important factors for the development of a pathological condition. We discuss the aspects of interstitial fluidopathy in various diseases, including Alzheimer’s disease, Parkinson’s disease, normal pressure hydrocephalus, and cerebral small vessel disease. We also discuss a method called “diffusion tensor image analysis along the perivascular space” using MR diffusion images, which is used to evaluate the degree of interstitial fluidopathy or the activity of the glymphatic system.
著者
Tsukasa Saida Ayumi Shikama Kensaku Mori Toshitaka Ishiguro Takeo Minaguchi Toyomi Satoh Takahito Nakajima
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0061, (Released:2022-11-12)
参考文献数
28
被引用文献数
1

Purpose: To compare MRI findings of high-grade serous carcinoma (HGSC) with and without breast cancer (BRCA) gene variants to explore the feasibility of MRI as a genetic predictor.Methods: We retrospectively reviewed MRI data from 16 patients with BRCA variant-positive (11 patients of BRCA1 and 5 patients of BRCA2 variant-positive) and 32 patients with BRCA variant-negative HGSCs and evaluated tumor size, appearance, nature of solid components, apparent diffusion coefficient (ADC) value, time-intensity curve, several dynamic contrast-enhanced curve descriptors, and nature of peritoneal metastasis. Age, primary site, tumor stage, bilaterality, presence of lymph node metastasis, presence of peritoneal metastasis, and tumor markers were also compared between the groups with the Mann-Whitney U and chi-square tests.Results: The mean tumor size of BRCA variant-positive HGSCs was 9.6 cm, and that of variant-negative HGSCs was 6.8 cm, with no significant difference (P = 0.241). No significant difference was found between BRCA variant-positive and negative HGSCs in other evaluated factors, except for age (mean age, 53 years old; range, 32–78 years old for BRCA variant-positive and mean age, 61 years old; range, 44–80 years old for BRCA variant-negative, P = 0.033). Comparing BRCA1 variant-positive and BRCA2 variant-positive HGSCs, BRCA1 variant-positive HGSCs were larger (P = 0.040), had greater Max enhancement (P = 0.013), Area under the curve (P = 0.013), and CA125 (P = 0.038), and had a higher frequency of lymph node metastasis (P = 0.049), with significance.Conclusion: There was no significant difference in the MRI findings between patients with HGSCs with and without BRCA variants. Although studied in small numbers, BRCA1 variant-positive HGSCs were larger and more enhanced than BRCA2 variant-positive HGSCs with higher CA125 and more frequent lymph node metastases, and may represent more aggressive features.
著者
Satoshi Funayama Utaroh Motosugi Shintaro Ichikawa Hiroyuki Morisaka Yoshie Omiya Hiroshi Onishi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0103, (Released:2022-11-08)
参考文献数
47

Purpose: To evaluate the feasibility of folded image training strategy (FITS) and the quality of images reconstructed using the improved model-based deep learning (iMoDL) network trained with FITS (FITS-iMoDL) for abdominal MR imaging.Methods: This retrospective study included abdominal 3D T1-weighted images of 122 patients. In the experimental analyses, peak SNR (PSNR) and structure similarity index (SSIM) of images reconstructed with FITS-iMoDL were compared with those with the following reconstruction methods: conventional model-based deep learning (conv-MoDL), MoDL trained with FITS (FITS-MoDL), total variation regularized compressed sensing (CS), and parallel imaging (CG-SENSE). In the clinical analysis, SNR and image contrast were measured on the reference, FITS-iMoDL, and CS images. Three radiologists evaluated the image quality using a 5-point scale to determine the mean opinion score (MOS).Results: The PSNR of FITS-iMoDL was significantly higher than that of FITS-MoDL, conv-MoDL, CS, and CG-SENSE (P < 0.001). The SSIM of FITS-iMoDL was significantly higher than those of the others (P < 0.001), except for FITS-MoDL (P = 0.056). In the clinical analysis, the SNR of FITS-iMoDL was significantly higher than that of the reference and CS (P < 0.0001). Image contrast was equivalent within an equivalence margin of 10% among these three image sets (P < 0.0001). MOS was significantly improved in FITS-iMoDL (P < 0.001) compared with CS images in terms of liver edge and vessels conspicuity, lesion depiction, artifacts, blurring, and overall image quality.Conclusion: The proposed method, FITS-iMoDL, allowed a deeper MoDL reconstruction network without increasing memory consumption and improved image quality on abdominal 3D T1-weighted imaging compared with CS images.
著者
Miho Gomyo Kazuhiro Tsuchiya Kenichi Yokoyama
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0140, (Released:2022-11-03)
参考文献数
74
被引用文献数
2

With the increasing use of 3-tesla MRI scanners and the development of applicable sequences, it has become possible to achieve high-resolution, good contrast imaging, which has enabled the imaging of the walls of small-diameter intracranial arteries. In recent years, the usefulness of vessel wall imaging has been reported for numerous intracranial arterial diseases, such as for the detection of vulnerable plaque in atherosclerosis, diagnosis of cerebral arterial dissection, prediction of the rupture of cerebral aneurysms, and status of moyamoya disease and cerebral vasculitis. In this review, we introduce the histological characteristics of the intracranial artery, discuss intracranial vessel wall imaging methods, and review the findings of vessel wall imaging for various major intracranial arterial diseases.
著者
Mohamed Jarraya Luis E. Diaz Frank W. Roemer William F. Arndt Ajay R. Goud Ali Guermazi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.17, no.3, pp.195-202, 2018 (Released:2018-07-10)
参考文献数
36
被引用文献数
10 26

Peripatellar fat pads are intracapsular extrasynovial adipose cushions that accommodate the changing shape and volume of articular spaces during movement. Variations in bone geometry, passive and active stabilization mechanisms and/or functional demands may lead to peripatellar fat pad abnormalities. While peripatellar fat pads may be affected a variety of conditions such as synovial inflammation, tumor and fibrosis, a mechanical origin should also be considered. Commonly, the clinical term “impingement” is used synonymously in the radiological literature to refer to three distinct entities of structural peripatellar fat pad abnormalities: superolateral the infrapatellar fat pad (Hoffa fat pad) edema, suprapatellar fat pad edema, and prepatellar fat pad edema, implying a mechanical origin of these conditions. The aim of this pictorial review is to describe the normal anatomy of the extensor mechanism of the knee, and discuss the relation of patellofemoral maltracking to the above-mentioned peripatellar fat pad conditions based on current evidence.
著者
Kazuki Oyama Fumihito Ichinohe Akira Yamada Yoshihiro Kitoh Yasuo Adachi Hayato Hayashihara Marcel D. Nickel Katsuya Maruyama Yasunari Fujinaga
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0035, (Released:2022-08-23)
参考文献数
13
被引用文献数
2

Purpose: The optimal temporal resolution for free-breathing dynamic contrast-enhanced MRI (FBDCE-MRI) of the pancreas has not been determined. This study aimed to evaluate the appropriate temporal resolution to achieve good image quality and to perform pharmacokinetic analysis in FBDCE-MRI of the pancreas using golden-angle radial sparse parallel (GRASP).Methods: Sixteen participants (53 ± 15 years, eight females) undergoing FBDCE-MRI were included in this prospective study. Images were retrospectively reconstructed at four temporal resolutions (1.8, 3.0, 4.8, and 7.8s). Two radiologists (5 years of experience) evaluated the image quality of each reconstructed image by assessing the visualization of the celiac artery (CEA), the common hepatic artery, the splenic artery, each area of the pancreas, and artifacts using a 5-point scale. Using Tissue-4D, pharmacokinetic parameters were calculated for each area in the reconstructed images at each temporal resolution for 16 examinations, excluding two with errors in the pharmacokinetic modeling analysis. Friedman and Bonferroni tests were used for analysis. A P value < 0.05 was considered statistically significant.Results: During vascular assessment, only scores for the CEA at 7.8s were significantly lower than the other temporal resolutions. Scores of all pancreatic regions and artifacts were significantly lower at 1.8s than at 4.8s and 7.8s. In the pharmacokinetic analysis, all volume transfer coefficients (Ktrans), rate constants (Kep), and the initial area under the concentration curve (iAUC) in the pancreatic head and tail were significantly lower at 4.8s and 7.8s than at 1.8s. iAUC in the pancreatic body and extracellular extravascular volume fraction (Ve) in the pancreatic head were significantly lower at 7.8s than at 1.8s.Conclusion: A temporal resolution of 3.0s is appropriate to achieve image quality and perform pharmacokinetic analysis in FBDCE-MRI of the pancreas using GRASP.
著者
Yo Taniguchi Suguru Yokosawa Toru Shirai Ryota Sato Tomoki Amemiya Yoshihisa Soutome Yoshitaka Bito Hisaaki Ochi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0045, (Released:2022-07-30)
参考文献数
21
被引用文献数
3

Purpose: MR parameter mapping is a technique that obtains distributions of parameters such as relaxation time and proton density (PD) and is starting to be used for disease quantification in clinical diagnoses. Quantitative susceptibility mapping is also promising for the early diagnosis of brain disorders such as degenerative neurological disorders. Therefore, we developed an MR quantitative parameter mapping (QPM) method to map four tissue-related parameters (T1, T2*, PD, and susceptibility) and B1 simultaneously by using a 3D partially RF-spoiled gradient echo (pRSGE). We verified the accuracy and repeatability of QPM in phantom and volunteer experiments.Methods: Tissue-related parameters are estimated by varying four scan parameters of the 3D pRSGE: flip angle, RF-pulse phase increment, TR and TE, performing multiple image scans, and finding a least-squares fit for an intensity function (which expresses the relationship between the scan parameters and intensity values). The intensity function is analytically complex, but by using a Bloch simulation to create it numerically, the least-squares fitting can be used to estimate the quantitative values. This has the advantage of shortening the image-reconstruction processing time needed to estimate the quantitative values than with methods using pattern matching.Results: A 1.1-mm isotropic resolution scan covering the whole brain was completed with a scan time of approximately 12 minutes, and the reconstruction time using a GPU was approximately 1 minute. The phantom experiments confirmed that both the accuracy and repeatability of the quantitative values were high. The volunteer scans also confirmed that the accuracy of the quantitative values was comparable to that of conventional methods.Conclusion: The proposed QPM method can map T1, T2*, PD, susceptibility, and B1 simultaneously within a scan time that can be applied to human subjects.
著者
Shota Kondo Yuko Nakamura Toru Higaki Takashi Nishihara Masahiro Takizawa Toru Shirai Motoshi Fujimori Yoshitaka Bito Keigo Narita Takahiro Sueoka Yukiko Honda Chihiro Tani Kazuo Awai
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0041, (Released:2022-06-01)
参考文献数
26

Purpose: The wavelet denoising with geometry factor weighting (g-denoising) method can reduce the image noise by adapting to spatially varying noise levels induced by parallel imaging. The aim of this study was to investigate the clinical applicability of g-denoising on hepatobiliary-phase (HBP) images with gadoxetic acid.Methods: We subjected 53 patients suspected of harboring hepatic neoplastic lesions to gadoxetic acid-enhanced HBP imaging with and without g-denoising (g+HBP and g–HBP). The matrix size was reduced for g+HBP images to avoid prolonging the scanning time. Two radiologists calculated the SNR, the portal vein-, and paraspinal muscle contrast-to-noise ratio (CNR) relative to the hepatic parenchyma (liver-to-portal vein- and liver-to-muscle CNR). Two other radiologists independently graded the sharpness of the liver edge, the visibility of intrahepatic vessels, the image noise, the homogeneity of liver parenchyma, and the overall image quality using a 5-point scale. Differences between g–HBP and g+HBP images were determined with the two-sided Wilcoxon signed-rank test.Results: The liver-to-portal- and liver-to-muscle CNR and the SNR were significantly higher on g+HBP- than g–HBP images (P < 0.01), as was the qualitative score for the image noise, homogeneity of liver parenchyma, and overall image quality (P < 0.01). Although there were no significant differences in the scores for the sharpness of the liver edge or the score assigned for the visibility of intrahepatic vessels (P = 0.05, 0.43), with g+HBP the score was lower in three patients for the sharpness of the liver edge and in six patients for the visibility of intrahepatic vessels.Conclusion: At gadoxetic acid-enhanced HBP imaging, g-denoising yielded a better image quality than conventional HBP imaging although the anatomic details may be degraded.
著者
Ying Yang Kuanghui Xu Xiaofei Chen Jianping Ding Junping Shi Jie Li
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0168, (Released:2022-06-07)
参考文献数
46
被引用文献数
3

Purpose: The Multi-echo Dixon (ME-Dixon) is a non-invasive quantitative MRI technique to diagnose non-alcoholic fatty liver disease (NAFLD). In this study, the hydrogen proton MR spectroscopy (1H-MRS) was used as a reference to explore the accuracy of the ME-Dixon technique in evaluating hepatic steatosis in NAFLD patients after ingesting formulated food and its correlation with changes in clinical indicators.Methods: Twenty-seven patients with NAFLD were enrolled. Fifteen patients completed 12 weeks of treatment with prebiotics and dietary fiber. In addition, abdominal MRI scans and blood tests were performed before and after treatment. The MRI-proton density fat fraction (MRI-PDFF) and MRS-PDFF were measured using the ME-Dixon and 1H-MRS techniques. The Bland–Altman method and Pearson correlation analysis were used to test the consistency of the two techniques for measuring the liver fat content and the changed values. Besides, correlation analysis was conducted between the MRI-PDFF value and metabolic indicators.Results: In the PDFF quantification of 42 person-times and the monitoring of the PDFF change in 15 patients under treatment, there was a good consistency and a correlation between MRI and MRS. At baseline, MRI-PDFF was positively correlated with insulin resistance index (HOMA-IR), fatty liver index (FLI), and liver enzymes. After treatment, the changes in MRI-PDFF were positively correlated with the recovery degree of FLI and liver enzymes.Conclusion: ME-Dixon has a good consistency and a correlation with MRS in quantifying the liver fat content and monitoring the treatment effect, which may be used as an accurate indicator for clinical monitoring of changes in the liver fat content.
著者
Nobuhiro FUJITA Akihiro NISHIE Yoshiki ASAYAMA Kousei ISHIGAMI Yasuhiro USHIJIMA Yukihisa TAKAYAMA Daisuke OKAMOTO Koichiro MORITA Ken SHIRABE Kazuhiro KOTO Yuichiro KUBO Yoshinao ODA Hiroshi HONDA
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
vol.15, no.1, pp.111-120, 2016-01-01 (Released:2016-01-12)
参考文献数
28
被引用文献数
7 9

Purpose: We attempted to clarify the relationship between the signal intensity (SI) in the hepatobiliary phase of gadoxetic acid-enhanced magnetic resonance (MR) imaging and the efficacy of hepatic arterial infusion chemotherapy (HAIC) in hepatocellular carcinomas (HCCs).Methods: We enrolled 14 patients with HCCs who underwent gadoxetic acid-enhanced MR imaging prior to HAIC using cisplatin and 5-fluorouracil. In the hepatobiliary phase, we calculated the SI of the HCCs and the background liver. In cases with multiple HCCs, we calculated the SI of the largest lesion. Patients were classified into high (n = 7) and low intensity (n = 7) groups based on the median value of the SI ratio (SI of the tumor/SI of the background liver). We analyzed progression-free survival using the Kaplan-Meier method and the log-rank test. In the 5 patients with a history of HCC surgery, we compared the expression of immunohistochemical organic anion-transporting polypeptide (OATP) 8 between the high and low intensity groups by chi-square test.Results: The SI ratios were 0.568 ± 0.093 (mean ± standard deviation) in the high intensity group and 0.251 ± 0.086 in the low intensity group. Compared to the group with low signal intensity, the group with high signal intensity demonstrated significantly lower serum levels of alpha fetoprotein (AFP) (P = 0.0350), significantly higher progression-free survival (P = 0.0108), better differentiation of tumor grade at histologic examination (P = 0.0253), and significantly higher OATP8 expression (P = 0.0253).Conclusion: Patients with HCCs of high SI ratio in the hepatobiliary phase of gadoxetic acid-enhanced MR imaging can respond better to HAIC.
著者
Yushi Tsujita Keitaro Sofue Eisuke Ueshima Yoshiko Ueno Masatoshi Hori Takamichi Murakami
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0152, (Released:2022-05-18)
参考文献数
112
被引用文献数
3

Viral hepatitis was previously the most common cause of chronic liver disease. However, in recent years, nonalcoholic fatty liver disease (NAFLD) cases have been increasing, especially in developed countries. NAFLD is histologically characterized by fat, fibrosis, and inflammation in the liver, eventually leading to cirrhosis and hepatocellular carcinoma. Although biopsy is the gold standard for the assessment of the liver parenchyma, quantitative evaluation methods, such as ultrasound, CT, and MRI, have been reported to have good diagnostic performances. The quantification of liver fat, fibrosis, and inflammation is expected to be clinically useful in terms of the prognosis, early intervention, and treatment response for the management of NAFLD. The aim of this review was to discuss the basics and prospects of MRI-based tissue quantifications of the liver, mainly focusing on proton density fat fraction for the quantification of fat deposition, MR elastography for the quantification of fibrosis, and multifrequency MR elastography for the evaluation of inflammation.
著者
Toshihiko Ebisu Masaki Fukunaga Tomokazu Murase Toyoshi Matsuura Naoya Tomura Yasuhiro Miyazaki Shinpei Osaki Tsutomu Okada Toshihiro Higuchi Masahiro Umeda
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0010, (Released:2022-04-02)
参考文献数
42
被引用文献数
1

Purpose: To determine if functional connectivity measured with resting-state functional MRI could be used as a tool to assess unilateral spatial neglect during stroke recovery.Methods: Resting-state functional MRI was performed on 13 stroke patients with lesions in the right cerebral hemisphere and 31 healthy subjects. The functional connectivity score was defined as a correlation of a target region with the right inferior parietal lobule. Spatial neglect was measured with a behavioral inattention test.Results: First, the functional connectivity scores between the right inferior parietal lobule and right inferior frontal gyrus, including the opercular and triangular parts, were significantly decreased in stroke patients with unilateral spatial neglect compared with patients without unilateral spatial neglect and were significantly correlated with the behavioral inattention test score. Second, the functional connectivity scores between the bilateral inferior parietal lobules were also significantly decreased in patients with unilateral spatial neglect compared with patients without unilateral spatial neglect and were significantly correlated with the behavioral inattention test score. Third, negative functional connectivity scores between the right inferior parietal lobule and bilateral medial orbitofrontal cortexes, which are related to the default mode network, were detected in patients without unilateral spatial neglect in contrast to a reduction of this negative tendency in patients with unilateral spatial neglect. The functional connectivity scores between these regions were significantly different between patients with and without unilateral spatial neglect and were negatively correlated with the behavioral inattention test score.Conclusion: Though still in the pilot research stage and using a small number of cases, our findings are consistent with the hypothesis that functional connectivity maps generated with resting-state functional MRI may be used as a tool to evaluate unilateral spatial neglect during stroke recovery.
著者
Masayuki Yamaguchi Kosuke Kojo Mizuki Akatsuka Tomoyuki Haishi Tatsushi Kobayashi Takahito Nakajima Hiroyuki Nishiyama Hirofumi Fujii
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.tn.2021-0130, (Released:2022-03-23)
参考文献数
13

We have developed a new device, consisting of a 3-cm RF coil and an immobilizer, to acquire high-resolution MR images of the testis. With the approval of our institutional review board, we conducted an MRI study on a cohort of healthy volunteers to test this device. With the participants in the supine position, we placed the dedicated immobilizer and RF coil on the scrotum for typically no more than 3 min. Subsequently, T2-weighted images were acquired with an in-plane resolution of 117 µm using a 3-T MR scanner and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) sequence. The total scan time ranged from 12 to 30 min (average 20 min). High-resolution MR images of the testis were acquired without deterioration by motion artifacts. Our results showed that the combined use of a small RF coil and an immobilizer is a feasible option for acquiring high-resolution MR images of the testis.
著者
Shintaro Ichikawa Utaroh Motosugi Tetsuya Wakayama Hiroyuki Morisaka Satoshi Funayama Daiki Tamada Kang Wang Sagar Mandava Ty A Cashen Hiroshi Onishi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0143, (Released:2022-03-17)
参考文献数
25
被引用文献数
7

Purpose: To compare the quality of dynamic imaging between stack-of-stars acquisition without breath-holding (DISCO-Star) and the breath-holding method (Cartesian LAVA and DISCO).Methods: This retrospective study was conducted between October 2019 and February 2020. Two radiologists performed visual assessments of respiratory motion or pulsation artifacts, streak artifacts, liver edge sharpness, and overall image quality using a 5-point scale for two datasets: Dataset 1 (n = 107), patients with Cartesian LAVA and DISCO-Star; Dataset 2 (n = 41), patients with DISCO and DISCO-Star at different time points. Diagnosable image quality was defined as ≥ 3 points in overall image quality. Whether the scan timing of the arterial phase (AP) was appropriate was evaluated, and results between the pulse sequences were compared. In cases of inappropriate scan timing in the DISCO-Star group, retrospective reconstruction with a high frame rate (80 phases, 3 s/phase) was added.Results: The overall image quality of Cartesian LAVA was better than that of DISCO-Star in AP. However, noninferiority was shown in the ratio of diagnosable images between Cartesian LAVA and DISCO-Star in AP. There was no significant difference in the ratio of appropriate scan timing between DISCO-Star and Cartesian LAVA; however, the ratio of appropriate scan timing in DISCO-Star with high frame rate reconstruction was significantly higher than that in Cartesian LAVA in both readers. Overall image quality scores between DISCO and DISCO-Star were not significantly different in AP. There was no significant difference in the ratio of appropriate scan timing between DISCO-Star with high frame rate reconstruction and DISCO in both readers.Conclusion: The use of DISCO-Star with high frame rate reconstruction is a good solution to obtain appropriate AP scan timing compared with Cartesian LAVA. DISCO-Star showed equivalent image quality in all phases and in the ratio of appropriate AP scan timing compared with DISCO.
著者
Sho Maruyama Sayuri Tatsuo Soichiro Tatsuo Saya Iida Fumiyasu Tsushima Satoru Ide Shingo Kakeda
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0144, (Released:2022-03-17)
参考文献数
45

Purpose: The human primary auditory cortex is located in the Heschl’s gyrus (HG). To assess the intrinsic MR property in the gray matter of the HG (GM-HG) with T1 and T2 values using a commercially available MR fingerprinting (MRF) technique.Methods: The subjects were 10 healthy volunteers (with 20 HGs; mean age, 31.5 years old; range, 25–53 years old). Coronal T1 and T2 maps were obtained with commercially available MRF using a 3-Tesla MR system. Two radiologists measured the T1 and T2 values of the GM-HG, the GM in the superior temporal gyrus (GM-STG), and the GM in the middle temporal gyrus (GM-MTG) by drawing a ROI on coronal maps.Results: For both radiologists, the mean T1 and T2 values of the GM-HG were significantly lower than those in the GM-STG or GM-MTG (P < 0.01). The interobserver reliability using the intraclass correlation coefficients (ICC) (2,1) showed strong agreement for the measurement of the T1 and T2 values (ICCs =⃥ 0.80 and 0.78 for T1 and T2 values, respectively).Conclusion: The T1 and T2 values on MRF for the GM-HG were lower than those for the GM-STG and GM-MTG, likely reflecting a higher myelin content and iron deposition in the GM-HG. Quantitative measurements using the MRF can clarify cortical properties with high reliability, which may indicate that MRF mapping provides new insights into the structure of the human cortical GM.
著者
Takahiko Nakazono Ken Yamaguchi Ryoko Egashira Mizuki Iyadomi Kazuya Fujiki Sachiho Takayanagi Masanobu Mizuguchi Hiroyuki Irie
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.rev.2021-0098, (Released:2022-03-17)
参考文献数
60
被引用文献数
1

The anterior mediastinum is the most common location of mediastinal tumors, and thymic epithelial tumors are the most common mediastinal tumors. It is important to differentiate thymic epithelial tumors from malignant lymphomas and malignant germ cell tumors because of the different treatment strategies. Dynamic contrast-enhanced MRI and diffusion-weighted imaging can provide additional information on the differential diagnosis. Chemical shift imaging can detect tiny fat tissues in the lesion and is useful in differentiating thymic hyperplasia from other solid tumors such as thymomas. MRI findings reflect histopathological features of mediastinal tumors, and a comprehensive evaluation of MRI sequences is important for estimation of the histopathological features of the tumor. In this manuscript, we describe the MRI findings of anterior mediastinal solid tumors and the role of MRI in the differential diagnosis.
著者
Hirotaka Muraoka Takashi Kaneda Naohisa Hirahara Kotaro Ito Shunya Okada Takumi Kondo
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0153, (Released:2022-03-11)
参考文献数
30
被引用文献数
1

Purpose: Chronic diffuse sclerosing osteomyelitis (CDSO) is a non-suppurative inflammatory bone disease diagnosed based on combined clinical, histopathological, and radiological findings. Accurate diagnosis is important since CDSO is more refractory to treatment than suppurative osteomyelitis. The purpose of this study was to determine the diagnostic efficacy of diffusion-weighted imaging (DWI) in the quantitative assessment of CDSO to distinguish it from acute suppurative osteomyelitis (ASO) and chronic suppurative osteomyelitis (CSO) of the mandible.Methods: Using a retrospective cohort study design, we analyzed MRI data of 6 patients with CDSO and 34 patients with ASO and CSO. The mean apparent diffusion coefficient (ADC) values of the three groups (CDSO, ASO, and CSO groups) were calculated, and differences were analyzed using Kruskal–Wallis and post-hoc Mann–Whitney tests with Bonferroni adjustments. We performed a receiver operating characteristic (ROC) curve analysis to evaluate the ability of the ADC to predict CDSO. P < 0.05 was considered statistically significant.Results: The mean ADCs in the CDSO, ASO, and CSO groups were 1.22 ± 0.04 × 10–3 mm2/s, 1.28 ± 0.08 × 10–3 mm2/s, and 1.06 ± 0.09 × 10–3 mm2/s, respectively. Significant differences were observed between the ASO and CSO groups (P < 0.001) and CSO and CDSO groups (P < 0.01). However, there was no significant difference between the ASO and CDSO groups (P = 0.21). The ROC analysis revealed a cut-off ADC value of 1.19 for distinguishing the CSO group from the CDSO group. Sensitivity, specificity, accuracy, and area under the ROC curve were 1.0, 0.92, 0, 95, and 0.94, respectively.Conclusion: The results suggest that ADC may be useful in distinguishing CDSO from mandibular suppurative osteomyelitis.
著者
Akinori Yamaguchi Kohsuke Kudo Ryota Sato Yasuo Kawata Niki Udo Masaaki Matsushima Ichiro Yabe Makoto Sasaki Masafumi Harada Noriyuki Matsukawa Toru Shirai Hisaaki Ochi Yoshitaka Bito
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0015, (Released:2022-03-10)
参考文献数
28
被引用文献数
3

Purpose: Studies on quantitative susceptibility mapping (QSM) have reported an increase in magnetic susceptibilities in patients with Alzheimer’s disease (AD). Despite the pathological importance of the brain surface areas, they are sometimes excluded in QSM analysis. This study aimed to reveal the efficacy of QSM analysis with brain surface correction (BSC) and/or vein removal (VR) procedures.Methods: Thirty-seven AD patients and 37 age- and sex-matched, cognitively normal (CN) subjects were included. A 3D-gradient echo sequence at 3T MRI was used to obtain QSM. QSM images were created with regularization enabled sophisticated harmonic artifact reduction for phase data (RESHARP) and constrained RESHARP with BSC and/or VR. We conducted ROI analysis between AD patients and CN subjects who did or did not undergo BSC and/or VR using a t-test, to compare the susceptibility values after gray matter weighting.Results: The susceptibility values in RESHARP without BSC were significantly larger in AD patients than in CN subjects in one region (precentral gyrus, 8.1 ± 2.9 vs. 6.5 ± 2.1 ppb) without VR and one region with VR (precentral gyrus, 7.5 ± 2.8 vs. 5.9 ± 2.0 ppb). Three regions in RESHARP with BSC had significantly larger susceptibilities without VR (precentral gyrus, 7.1 ± 2.0 vs. 5.9 ± 2.0 ppb; superior medial frontal gyrus, 5.7 ± 2.6 vs. 4.2 ± 3.1 ppb; putamen, 47,8 ± 16.5 vs. 40.0 ± 15.9 ppb). In contrast, six regions showed significantly larger susceptibilities with VR in AD patients than in CN subjects (precentral gyrus, 6.4 ± 1.9 vs. 4.9 ± 2.7 ppb; superior medial frontal gyrus, 5.3 ± 2.7 vs. 3.7 ± 3.3 ppb; orbitofrontal cortex, –2.1 ± 2.7 vs. –3.6 ± 3.2 ppb; parahippocampal gyrus, 0.1 ± 3.6 vs. –1.7 ± 3.7 ppb; putamen, 45.0 ± 14.9 vs. 37.6 ± 14.6 ppb; inferior temporal gyrus, –3.4 ± 1.5 vs. –4.4 ± 1.5 ppb).Conclusion: RESHARP with BSC and VR showed more regions of increased susceptibility in AD patients than in CN subjects. This study highlights the efficacy of this method in facilitating the diagnosis of AD.
著者
Hirotaka Yamamoto Mami Iima Yo Kishimoto Ayami Ohno Kishimoto Sho Koyasu Akira Yamamoto Yoshitaka Kawai Akira Yoshizawa Koichi Omori
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0149, (Released:2022-03-04)
参考文献数
26
被引用文献数
1

Purpose: To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion-weighted imaging (DWI) can reduce image distortion and improve the lesion identification in parathyroid adenomas (PTAs) compared to single-shot EPI (SS-EPI) DWI, and to determine whether PTAs can be differentiated from other soft tissue structures of the head and neck region by using the apparent diffusion coefficient (ADC) value.Methods: We retrospectively analyzed the preoperative MR images including DWI of 24 patients with surgically confirmed PTA. RS-EPI and SS-EPI DWI were evaluated by two independent readers for the identification of the lesions and distortion. The ADC values of the PTAs were compared with those of thyroid glands and cervical lymph nodes.Results: RS-EPI provided significantly less distortion compared to SS-EPI. RS-EPI tended to have better lesion identification compared with SS-EPI without a statistically significant difference. On SS-EPI, the PTAs had significantly higher ADC values compared with the cervical lymph nodes. On RS-EPI, the PTAs had significantly higher ADC values compared with the thyroid glands and cervical lymph nodes.Conclusion: RS-EPI reduces the DWI distortion in PTAs. The ADC value obtained using RS-EPI enables the differentiation of PTAs from nearby structures, such as thyroid glands and cervical lymph nodes.