著者
鄭 椙元 堀越 哲美 梅村 茂樹 宮本 征一 水谷 章夫
出版者
日本建築学会
雑誌
日本建築学会計画系論文集 (ISSN:13404210)
巻号頁・発行日
vol.62, no.493, pp.77-84, 1997-03-30 (Released:2017-02-02)
参考文献数
29
被引用文献数
7 6

The purpose of this paper is to assess the solar radiation load on thermal comfort in outdoor thermal environments. An urban street canyon and an open space were selected as sites for field survey. Outdoor climatic conditions, subject's thermal sensation and skin temperatures were measured on the sites for a few day in summer, autumn and winter. A modified mean radiant temperature was introduced to indicate the effect of solar radiation and radiation interchange between outdoor objects on the human body. An operative temperature and a standard operative temperature were calculated based on the modified mean radiant temperature. There are high correlation between the operative or standard operative temperature and thermal sensation or mean skin temperature. Those indices, especially the standard operative temperature, are considered to be effective in the outdoor environment.
著者
井口 拓海 宮本 征一
出版者
人間‐生活環境系学会
雑誌
人間‐生活環境系シンポジウム報告集 第43回人間−生活環境系シンポジウム報告集 (ISSN:24348007)
巻号頁・発行日
pp.59-62, 2019 (Released:2021-04-23)
参考文献数
5

恒温恒湿室を、室温 26℃、相対湿度 50%で制御した熱的中立な環境下において、温冷覚閾値計を用いて青 年被験者 11 名の身体 13 部位の局所に温刺激を与える被験者実験を行った。温刺激を知覚するときの皮膚の温度 と熱流束および不快を知覚する温度と熱流束を測定した。その結果、温覚の感度が良い部位は、額、前腕、手背 など頭部や上肢部であり、温覚の感覚が悪い部位は、大腿前、大腿後、下腿前、下腿後、足背などの下肢部と胸 であった。不快知覚温度差は、知覚開始温度差と殆ど同様な部位間差が見られた。標準偏差は被験者間のバラツ キと考えられる。知覚開始温度の標準偏差は前腕 0.4℃、額 0.5℃、大腿後 0.5℃の順に小さく、足背 2.2℃、下腿 前 1.9℃、下腿部後 1.3℃の順に大きかった。
著者
冨田 明美 宮本 征一 堀越 哲美
出版者
日本生気象学会
雑誌
日本生気象学会雑誌 (ISSN:03891313)
巻号頁・発行日
vol.36, no.1, pp.43-51, 1999-04-01 (Released:2010-10-13)
参考文献数
14
被引用文献数
3

日本人青年男女の体表面積を得るため, 人間生活工学研究センター (HQL) による日本人の人体計測データ平均値を基準に体型の異なる男性3名, 女性3名を被験者として選出した.6名の被験者について非伸縮性接着テープ法により体表面積の実測を行った.また, 体表面積と既往研究の体表面積推定式との適合性について検討した.シルエッターにより得られるシルエット写像の面積を測定し, 体表面積との関係を検討した.得られた結果は次のようである.1) 体表面積は, 男性の平均で17895cm2, 女性の平均で14443cm2であった.2) 体表解剖学体表区分に準拠した体表区分の面積比率から, 男女とも臀部, 大腿部, 下腿部に被験者間の差が大きいことがわかった.蔵澄らの面積比率に比較して, 大腿部, 胸部が大きく, 臀部が小さくなる傾向がみられた.また, DuBiousの面積比率に比較して, 大腿部, 腕部が大きく, 体幹部が小さくなる傾向がみられた.3) 蔵澄, 高比良, DuBious, 新谷, Meeh, 村田, 藤本の体表面積推定式の適合性を検討した.男性では, DuBious, 蔵澄, 新谷, 高比良の計算式が被験者の実測体表面積と適合することが確認できた.女性では, DuBious, 蔵澄, 高比良の計算式が適合した.4) シルエッターにより得られたシルエット面積 (x) と体表面積 (y) との一次回帰式を求めた.人体方位角0°と90°において, シルエット面積と体表面積との間には, r=0.989以上の高い相関が認められた.シルエット面積から体表面積を推定する式として次式を提案した.方位角0°の場合は, y=3.430x+0.003, 方位角90°の場合は, y=6.264x-0.22
著者
宮本 征一 堀越 哲美 土川 忠浩
出版者
日本建築学会
雑誌
日本建築学会計画系論文集 (ISSN:13404210)
巻号頁・発行日
vol.62, no.498, pp.45-49, 1997
被引用文献数
2 2 1

The objective of this paper is to evaluate the thermal radiation environment using mean radiant temperature MRTr which takes configuration factors and equivalent black body temperatures the effect of the inter-reflection and blocking effect of the human body. Numerical analysis of inter-reflection radiant exchange were carried out using Net Radiation method. MRTr was calculated from radiation rate, emissivity and configuration factors on each surface. As a result, The difference between the MRT considering the effect of inter-reflection and the ordinary MRT stood within ±3℃ when the emissivity of a floor changed from 0.50 to 1.00 under the following floor heating condition : the floor surface temperature 37.5℃ and the other surface temperature 21℃. The MRT was influenced by emissivities of each surface in the non-uniform thermal radiation environments rather than uniform environment. It is necessary to evaluate the non-uniform thermal radiant environment using the MRT considering the effect of radiation inter-reflection and blocking effect of the human body.
著者
渡邊 慎一 堀越 哲美 三好 結城 宮本 征一
出版者
日本建築学会
雑誌
日本建築学会計画系論文集 (ISSN:13404210)
巻号頁・発行日
vol.62, no.497, pp.47-52, 1997
被引用文献数
18 9

A well-known heating facility in Japan, KOTATSU, heats the lower extremities of the human body by an infrared heater or wood coal fire in a box. The objective of this paper is to clarify the thermal effect of KOTATSU on the human thermal comfort quantitatively. Experiments were carried out under the following combined conditions: air temperatures were 1 1℃, 14℃, 17℃, and 20℃ and electric power of infrared lamp were to OW('off'), 87W('low'), 91W('middle') and 181W('high') electric consumption, respectively. Five male and six female subjects participated in those experiments. The following result was obtained: There was significant difference of comfort vote between female and male subjects when subjects reported hotter votes than thermal neutrality. The KOTATSU at 'low' and 'middle' IR heater level has the equivalent effect of 7℃ operative temperature rise at the condition of 11℃ air temperature, and that at 'high' IR heater level has the equivalent effect of 10℃ operative temperature rise at the same condition. Also the KOTATSU has more than 2℃ effectiveness at the condition of 14℃ air temperature even if the infrared lamp of the KOTATSU is turned off. Its effectiveness decrease gradually with increasing air temperature.