著者
望月 菜穂子 宇治川 正人 平手 小太郎 安岡 正人
出版者
日本建築学会
雑誌
日本建築学会計画系論文集 (ISSN:13404210)
巻号頁・発行日
vol.61, no.479, pp.17-25, 1996-01-30 (Released:2017-01-28)
参考文献数
12
被引用文献数
1 5

An experimental study to evaluate task-ambient lighting systems was carried out in a laboratory which varied in 4 types of lighting. After experiences for a total of 40 days ; ten days at a time, in a room for each type of lighting, fourteen subjects were asked to fill out a questionnaire relating to the visual satisfaction and six activities observed in the room. The evaluation of the task-ambient lighting depended on the work being performed. With increasing ambient illuminance, subjects were satisfied for reading and writing, or meetings. At an ambient illuminance of 200 lux, over 60% of the subjects were satisfied for accomplishing creative work. The low illuminance ambient lighting thus enabled them to concentrate on their creative work.