著者
堀川 教世 中山 英明 境田 彰芳 田中 道七
出版者
社団法人日本材料学会
雑誌
材料 (ISSN:05145163)
巻号頁・発行日
vol.49, no.4, pp.426-432, 2000-04-15
被引用文献数
2 4

Load-controlled fatigue tests were carried out on PAN-based monofilament carbon fibers under cyclic tensile load conditions at a frequency of 10Hz.Fatigue strength data are obtained under pre-determined maximum load P_max with three different stress ratios of R(=P_mix/P_max)=0.1, 0.5 and 0.7.The maximum load P_max is not an appropriate parameter to evaluate the fatigue strength behavior because the cross-sectional area of monofilament carbon fiber is not constant and varies along the longitudinal direction.This fact results in a large scatter of fatigue lives when the data are plotted on P_max-N_f diagram.In order to evaluate the evaluate the fatigue strength behavior more precisely, the fatigue strength data must be plotted on S-N diagram by using the maximum tensile stress σ_max determined from the crosssectional area of the fracture surface.It is found that S-N properties of monofilament carbon fibers clearly show the fatigue behavior, depending on the stress ratio R.It is also found that the fatigue strength of monofilament carbon fiber is governed by two parameters such as the maximum stress σ_max and the stress amplitude σ_a, and that the combined stress parameter σ_max~(1-α)×σ_a~α is useful to describe the fatigue strength behaviors of the different stress ratios.
著者
森好 浩行 三好 美紀 日野 大樹 中山 英樹 森川 俊雄 中木 真一 糸原 幸次
出版者
日本法科学技術学会
雑誌
日本法科学技術学会誌 (ISSN:18801323)
巻号頁・発行日
vol.12, no.1, pp.27-34, 2007 (Released:2007-06-27)
参考文献数
17
被引用文献数
8 8 1

Images of the ear are highly valuable for facial photographic identification because the ear has a lot of morphological features, such as the helix, ear lobe, antihelix, scapha, antitragus, tragus, and so on. However, the morphology of ear components changes so easily depending on the camera angle that it is usually difficult to identify people based on images of their ears from surveillance cameras and mug shots.   In this study, the correlation between the morphology of ear components and camera angles was investigated in order to identify people based on ear images taken from different camera angles. The samples were ear images of 56 persons taken at 27 different camera angles for each person. The morphologies of the ear components were compared among the angles and among the subjects. This revealed the morphological changes in the helix, ear lobe, antihelix, and tragus according to the camera angle.   It was found that the morphology was consistent between ear images taken at different camera angles if the compared images satisfied two conditions: the scapha must be clearly observed, and the external acoustic meatus must not be visible. If these conditions are met, it is possible to identify a person by images of his or her ear regardless of the camera angles.
著者
中山 英久 角田 裕 太田 耕平 鈴木 明宏 西山 大樹 永富 良一 橋本 和夫 和泉 勇治 キニ グレン マンスフィールド 根元 義章 加藤 寧
出版者
一般社団法人電子情報通信学会
雑誌
電子情報通信学会技術研究報告. CS, 通信方式 (ISSN:09135685)
巻号頁・発行日
vol.109, no.4, pp.1-6, 2009-04-09
被引用文献数
3

近年の健康志向の高まりを受け,各種トレーニングの運動効果が多くの人々の関心事となっている.本研究では,フィンランド発祥のエクササイズであるノルディックウォーキングの運動効果の検証を目的とし,ポータブルな屋外無線LANネットワークを用いて運動をリアルタイムにセンシングする,運動計測システムのプロトタイプを構築した.本システムは,無線端末と行動計測デバイスをセットとすることで,設置した無線ネットワーク内をユーザが自由に運動できるため,ネットワーク設備が不十分な屋外における運動でも各人の消費カロリー等を精密に計測できることが特徴である.プロトタイプシステムの有効性をノルディックウォーキングのイベントにおける実証実験を通じて検証し,多くの参加者から同時に運動のセンシングが可能であることを確認した.本稿では,運動計測システムの設計に関する課題を議論すると共に,実証実験の結果を報告する.