著者
阪本 浩 永井 康平 坂田 弘 江草 拓
出版者
Japan Society of Civil Engineers
雑誌
土木学会論文集 (ISSN:02897806)
巻号頁・発行日
vol.1986, no.373, pp.93-102, 1986-09-20 (Released:2010-08-24)
参考文献数
2

Tomari-ohashi bridge is located at the Naha coastal way connecting four wharves of Naha Harbor, Okinawa. The type of this bridge is three-span continuous steel decked box girder of 170-meter center span. Tomari-ohashi bridge stands fifth in Japan as regards the length of center span of this type. This paper describes leading characteristics of the planning, designing, construction and erection method of Tomari-ohashi bridge, and also a detailed explanation is given showing wind tunnel test results and suppressing methods of wind-induced vibration, which requires particular investigations.
著者
岡崎 好秀 宮城 淳 堀 雅彦 東 知宏 中村 由貴子 小坂田 弘子 紀 螢 Bazar Oyuntsetseg Rodis Omar 松村 誠士 下野 勉
出版者
一般財団法人 日本小児歯科学会
雑誌
小児歯科学雑誌 (ISSN:05831199)
巻号頁・発行日
vol.40, no.4, pp.693-700, 2002-09-25 (Released:2013-01-18)
参考文献数
37
被引用文献数
2

齲蝕のない3~5歳の小児114名を対象として,Dentocult-SM®strip Mutansテスト(Orion Diagnostica社製)を用い,ミュータンス連鎖球菌数について調べた。また小児の生活習慣に関する15問のアンケートを実施した。そしてミュータンス連鎖球菌数とアンケート項目との関係について数量化理論II類を用い解析した。さらに上位にランクされた項目についてはχ2検定を用い検討を加えた。1.Dentocult-SM(R) Strip mutansテストの判定結果の分布は,クラス0は69.3%(79/114名),クラス1は21.9%(25/114名),クラス2は8.8%(10/114名)であり,クラス3は1人もいなかった。2.以下の項目はミュータンス連鎖球菌数と有意に関係していた。1)間食の不規則摂取(χ2検定p<0.01)2)間食回数3回以上(χ2検定p<0.01)3)甘味飲料を多く飲む(χ2検定P<0.05)4)保護者の齲蝕が多い(χ2検定p<0.05)5)間食後の歯磨きをしない(χ2検定P<0.05)以上より,これらの項目に対する保健指導を行えば,ミュータンス菌の定着のリスクが減少し,ひいては小児の齲蝕予防につながることが期待できる。
著者
坂田 弘安 山崎 義弘 笠井 和彦
出版者
日本建築学会
雑誌
日本建築学会構造系論文集 (ISSN:13404202)
巻号頁・発行日
vol.79, no.695, pp.103-112, 2014-01-30 (Released:2014-07-10)
参考文献数
27
被引用文献数
3 3

In order to mitigate seismic damage of timber houses, application of passive control devises is demanded. The authors have developed high performance shear walls with various types of dampers, which are called “energy dissipation walls”. For the future, new design method has to be proposed to generalize passively controlled timber structures. In this paper, a method to evaluate allowable strength of shear wall is proposed. Advantage of passively controlled structure is to reduce maximum deformation, and energy dissipation walls are added to a structure so that maximum deformation angle of the structure subjected to level2 earthquake is less than target deformation. Accuracy of the method is demonstrated through a lot of non linear time history analyses.
著者
山崎 義弘 鈴木 滉哉 松田 和浩 坂田 弘安
出版者
一般社団法人 日本建築学会
雑誌
日本建築学会技術報告集 (ISSN:13419463)
巻号頁・発行日
vol.27, no.65, pp.202-206, 2021-02-20 (Released:2021-02-20)
参考文献数
7
被引用文献数
1

Seismic performance of timber shear walls is generally confirmed through experiment which is provided in the standard. However, the strength and deformation capacities are clearly related to the loading protocol, and such a fatigue behavior is not well-understood so far. In this paper, plywood sheathing wall having 12mm thickness of plywood is tested, and the fatigue behaviors coming up on force-deformation relation and equivalent damping ratio are evaluated.