著者
Teruhiko Imamura Koichiro Kinugawa Takashi Nishimura Koichi Toda Yoshikatsu Saiki Hiroshi Niinami Shinichi Nunoda Goro Matsumiya Motonobu Nishimura Hirokuni Arai Masanobu Yanase Norihide Fukushima Takeshi Nakatani Akira Shiose Ikuko Shibasaki Yasushi Sakata Minoru Ono J-MACS Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0264, (Released:2023-06-01)
参考文献数
18
被引用文献数
2

Background: Recently, destination therapy (DT) was approved in Japan, and patients ineligible for heart transplantation may now receive durable left ventricular assist devices (LVADs). Several conventional risk scores are available, but a risk score that is best to select optimal candidates for DT in the Japanese population remains unestablished.Methods and Results: A total of 1,287 patients who underwent durable LVAD implantation and were listed for the Japanese registry for Mechanically Assisted Circulatory Support (J-MACS) were eligible for inclusion. Finally, 494 patients were assigned to the derivation cohort and 487 patients were assigned to the validation cohort. According to the time-to-event analyses, J-MACS risk scores were newly constructed to predict 3-year mortality rate, consisting of age, history of cardiac surgery, serum creatinine level, and central venous pressure to pulmonary artery wedge pressure ratio >0.71. The J-MACS risk score had the highest predictability of 3-year death compared with other conventional scores in the validation cohort, including HeartMate II risk score and HeartMate 3 risk score.Conclusions: We constructed the J-MACS risk score to estimate 3-year mortality rate after durable LVAD implantation using large-scale multicenter Japanese data. The clinical utility of this scoring to guide the indication of DT should be validated in the next study.
著者
Manami Takahashi Hiroyuki Takaoka Satomi Yashima Noriko Suzuki-Eguchi Joji Ota Hideki Kitahara Kaoru Matsuura Goro Matsumiya Yoshio Kobayashi
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0288, (Released:2023-08-09)
参考文献数
40

Background: Extracellular volume fraction (ECV) on magnetic resonance imaging can predict prognosis after aortic valve replacement in patients with aortic stenosis (AS). However, the usefulness of ECV on computed tomography (CT) for patients who have undergone transcatheter aortic valve replacement (TAVR) is unclear, so we investigated whether ECV analysis on CT is associated with clinical outcomes in TAVR candidates.Methods and Results: We analyzed 127 patients with severe AS who underwent preoperative CT for TAVR. We evaluated the utility of ECV analysis on single-energy CT for predicting patient prognosis after TAVR. The primary outcome was a composite of all-cause death and hospitalization due to heart failure (HF) after TAVR. 15 patients (12%) had composite outcomes: 4 deaths and 11 hospitalizations due to HF. In multivariate survival analysis using the Cox proportional hazard model, atrial fibrillation (AF) (hazard ratio (HR), 7.86; 95% confidence interval (CI), 2.57–24.03; P<0.001), history of congestive HF (HR, 4.91; 95% CI, 1.49–16.2; P=0.009) and ECV ≥32.6% on CT (HR, 6.96; 95% CI, 1.92–25.12; P=0.003) were independent predictors of composite outcomes. On Kaplan-Meier analysis, the higher ECV group (≥32.6%) had a significantly greater number of composite outcomes than the lower ECV group (P<0.001).Conclusions: ECV on CT is an independent predictor of prognosis after TAVR.
著者
Akihiro Masuzawa Tomomitsu Takagi Hirokuni Arai Goro Matsumiya Shuichiro Takanashi Hitoshi Yaku Tatsuhiko Komiya Yoshiro Matsui Satoru Wakasa Takashi Kunihara
出版者
The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
雑誌
Annals of Thoracic and Cardiovascular Surgery (ISSN:13411098)
巻号頁・発行日
vol.28, no.1, pp.56-62, 2022 (Released:2022-02-20)
参考文献数
17

Objective: Mitral subvalvular procedures in addition to restrictive annuloplasty are promising for ischemic mitral regurgitation (IMR). However, the prevalence and efficacy of specific subvalvular repair in severe IMR have not been elucidated. This is the first nationwide survey regarding surgeons’ attitudes toward IMR in Japan.Methods: A questionnaire was sent to 543 institutions. From 2015 to 2019, numbers of elective first-time mitral valve replacement (MVR) with/without complete chordal preservation (CCP)/papillary muscle approximation (PMA) and mitral valvuloplasty (MVP) with/without papillary muscle relocation (PMR)/PMA in patients with severe IMR were collected. Concomitant procedures for coronary artery, tricuspid valve, and arrhythmia could be included but left ventricular reconstruction was excluded.Results: Completed questionnaires were received from 286 institutions (52.7%). The majority (90%) had less than 20 cases within 5 years. The number of MVP (1413, 61.5%) surpassed MVR (886, 38.5%). CCP was performed in half of MVR (50.0%), while PMA was included in only 1.9% of MVR. PMA and PMR were also performed infrequently, in only 7.7% and 10.9% of MVP, respectively.Conclusion: Japanese surgeons aggressively perform MVP for severe IMR. Subvalvular repair was also aggressively performed in addition to MVR, but not to MVP. A multicenter registry study is in progress.
著者
Teruhiko Imamura Koichiro Kinugawa Minoru Ono Osamu Kinoshita Norihide Fukushima Akira Shiose Yoshiro Matsui Kenji Yamazaki Yoshikatsu Saiki Akihiko Usui Hiroshi Niinami Goro Matsumiya Hirokuni Arai Yoshiki Sawa
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-18-1215, (Released:2019-04-24)
参考文献数
35
被引用文献数
7

Background:Hemocompatibility-related adverse events (HRAEs) are substantial issues in patients with left ventricular assist devices (LVADs). Atrial fibrillation (AF) is associated with worse prognosis in patients with heart failure (HF), but its effect on HRAEs following LVAD implantation remain uncertain.Methods and Results:Data from the Japanese Mechanically Assisted Circulatory Support registry of consecutive patients who received HeartMate II LVADs and were followed for 1 year were retrospectively reviewed. Among 190 patients, 23 had AF and 167 had sinus rhythm. The AF group had comparable baseline characteristics with the non-AF group except for their higher age (53 vs. 42 years, P<0.001). Following LVAD implantation, most cases of AF (73%) persisted. Antiplatelet therapy, anticoagulation therapy, and LVAD speed following LVAD implantation were comparable between groups (P>0.05 for all). The 1-year survival free from HRAEs was comparable between groups (83% vs. 76%, P=0.52). Event rates of the breakdown of HRAEs were comparable between groups except for a relatively higher rate of surgically managed pump thrombosis in the AF group (0.16 vs. 0.04, incidence rate ratio 3.75, 95% confidence interval 0.87–16.1, P=0.075). These trends still remained with propensity score-matched comparison.Conclusions:Existence of AF had no effect on the development of HRAEs following LVAD implantation. The need to aggressively treat AF before or after LVAD implantation needs further investigation.