著者
Yusuke Kondo Takashi Noda Yukiko Takanashi Shingo Sasaki Yasunori Sato Takashi Nitta Yoshifusa Aizwa Tohru Ohe Takashi Kurita
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0613, (Released:2023-12-07)
参考文献数
30
被引用文献数
2

Background: In 2016, the DANISH study reported negative results regarding the efficacy of implantable cardioverter-defibrillators (ICDs) in patients with non-ischemic cardiomyopathy (NICM) and reduced left ventricular ejection fraction (LVEF). In this study we determined the efficacy of using ICDs for primary prophylaxis in patients with NICM.Methods and Results: We selected 1,274 patients with underlying cardiac disease who were enrolled in the Nippon Storm Study. We analyzed the data of 451 patients with LVEF ≤35% due to NICM or ischemic cardiomyopathy (ICM) who underwent ICD implantation for primary prophylaxis (men, 78%; age, 65±12 years; LVEF, 25±6.4%; cardiac resynchronization therapy, 73%; ICM, 33%). After propensity score matching, we compared the baseline covariates between groups: NICM (132 patients) and ICM (132 patients). The 2-year appropriate ICD therapy risks were 27.7% and 12.2% in the NICM and ICM groups, respectively (hazard ratio, 0.390 [95% confidence interval, 0.218–0.701]; P=0.002).Conclusions: This subanalysis of propensity score-matched patients from the Nippon Storm Study revealed that the risk of appropriate ICD therapy was significantly higher in patients with NICM than in those with ICM.
著者
Kenji Ando Kanki Inoue Tomoo Harada Satoshi Shizuta Yukihiko Yoshida Kengo Kusano Tatsuya Onuki Yuji Watari Akio Fukui Shingo Sasaki Morio Shoda Nobuhiro Nishii Akira Shiose Junya Hosoda Chie Okai Kurt Stromberg Jeffrey Murphy Thomas R Holmes Kyoko Soejima
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0269, (Released:2023-08-02)
参考文献数
15
被引用文献数
2

Background: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.Methods and Results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate. The 30-day and 6-month major complication rates were compared to global Micra studies. All patients underwent successful implantation with an average follow-up of 7.23±2.83 months. Compared with previous Micra studies, Japanese patients were older, smaller, more frequently female, and had a higher pericardial effusion risk score. 11 acute major complications were reported in 10 patients for an acute complication rate of 3.33% (95% confidence interval: 1.61–6.04%), which was in line with global Micra trials. Pericardial effusion occurred in 4 patients (1.33%; 3 major, 1 minor). No procedure or device-related deaths occurred. Frailty significantly improved from baseline to follow-up as assessed by Japan Cardiovascular Health Study criteria.Conclusions: In a Japanese cohort, implantation of the Micra leadless pacemaker had a high success rate and low major complication rate. Despite the Japan cohort being older, smaller, and at higher risk, the safety and performance was in line with global Micra trials.