The hands of the analog watch can be thrown off by exposure to strong magnetism or impact. So we developed a new mechanism and algorithm of auto hand position correction for the analog watch. It detects the position of the hands periodically and adjusts them to the correct position if it discovers any discrepancy, and it corrects all three hands (hour, minute, and second hand) position by using one set of detection device.
著者
茂木 正俊 中田 克美 広瀬 信行
出版者
一般社団法人 日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.58, no.210, pp.7-18, 2014-06-10 (Released:2017-11-09)

We have developed a minute repeater mechanism based on the SPRING DRIVE movement. Within the limited dimensions of a movement, we have increased the duration time to a maximum and moreover, we have founded the means shown below in order to avoid the troubles caused by wrong operations of users. 1. By the means of two main spring barrels placed in series, we have increased the running time of the watch. 2. By modifying the minute repeater mechanism and turning it into the Sonnerie center wheel, it was possible to remove the minute repeaters spring and draw the mechanical energy directly from the main spring barrel. 3. While the minute repeater mechanism works, if the lever that releases the center wheel is used, the crown cannot be pulled out because it is equipped with a security system in order not to activate the minute repeater when the crown is in "pull out" position.
著者
金坂 俊哉 小棚木 進 中林 靖 間峠 彰弘
出版者
一般社団法人 日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.43, no.3, pp.29-36, 1999-09-10 (Released:2017-11-09)
被引用文献数
1

This paper describes the development of a thermal energy watch. The Cal. 6C is the thermal energy watch that converts body heat into power. The watch has an ultra compact power generation system with a power generation monitoring function and a power saving function that gradually stops the hands when no power is generated. It also has a fully automatic perpetual calendar function valid through February 28, 2100.
著者
ステファン カレン デニス マギー 久保田 浩司
出版者
一般社団法人日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.45, no.4, pp.94-102, 2001-12-10

1960年代後半に, 日本, スイスおよびアメリカ合衆国でそれぞれ別個に作業していたエンジニアのチームは, 完全に新しく創造された電子コンポーネントを用いてリストウオッチを再開発する.これらのチームが開発した製品は時計産業にグローバルな革命を刺激し, 総ての人に, 必要かどうかに係わらず, これまでは科学者と技術者だけが使用した正確無比(秒以下)を受容するかどうかを問うた.この時間測定の急激な変革は, 機械技術から電子の世界への劇的な移行の先駆けと歴史の盛り上がりによるものだった.三つの技術者チームによる成果の検証をこの論文は比較アプローチの手法でどのように文化, 経済, 経営の仕組み, 技術知識入手の容易さなどの地域の相違が完成品のデザインとユーザーの受容に作用したかを提言する.
著者
苗村 潔 齋藤 英也
出版者
一般社団法人日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.49, no.193, pp.38-44, 2005-12-10
被引用文献数
3

Epidural anesthesia is one of the regional anesthesias used for the abdominal surgery and the obstetric analgesia for labor. An anesthesiologist need to place the needle tip at the epidural space precisely, according to decrease of the puncture force when the needle tip enters in the epidural space. No study examined the relation between the tip shape and the force curve. In this paper, six needles were compared by a phantom study.
著者
苗村 潔 齋藤 英也
出版者
一般社団法人 日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.49, no.193, pp.38-44, 2005
参考文献数
16
被引用文献数
3

Epidural anesthesia is one of the regional anesthesias used for the abdominal surgery and the obstetric analgesia for labor. An anesthesiologist need to place the needle tip at the epidural space precisely, according to decrease of the puncture force when the needle tip enters in the epidural space. No study examined the relation between the tip shape and the force curve. In this paper, six needles were compared by a phantom study.
著者
赤尾 祐司
出版者
一般社団法人 日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.45, no.1, pp.27-33, 2001
参考文献数
2

With the purpose of improving performance of lubricant at low temperature and unifying lubricants to be used, we made new synthetic lubricant for watch mechamism. In this paper, we selected ester oil among several kinds of synthetic oils. We found that ester, as base oil, was superior in performance at low temperature and cahracteristic of evaporation rate, which has three ester groups in one molecule synthesized with tri-methylopropane and alkyl acid. We defined that the viscosity of the above mentioned lubricant should be 15cSt to 1000cSt at its used temperature range(-30 to 80°C). We found by evaluating performance of watches that the consumption electric current and the voltage to start moving with the lubricant at the used temperature are both almost same as with the existing lubricants. We also found by evaluating durability by accelerating test that the performance of the train wheel movement for twenty years is almost same. From the above we can obtain the new lubricant for watches which is superior in performance at low temperature and which we can apply for every part in watches.

1 0 0 0 等時性(4)

著者
小牧 昭一郎
出版者
一般社団法人 日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.46, no.1, pp.67-75, 2002
被引用文献数
1

本稿では立等時性に関するもっとも知られている二つの事項、てんわの片重りとひげぜんまいの重心移動に関して解説を行なった。ここでひげぜんまいの重心移動とはテンプの振動に伴って発生するものをいい、ひげの取付具合による偏心などを意味するものではない。ひげぜんまいの重心移動に関しては観察者の目をひげ玉に乗せたとして新しい説明を試みた。また、ひげぜんまいの重心移動の軌跡に関しては新しい、正確な考え方を紹介した。偏心の取れた正確なひげぜんまいの重心点は静止位置にあってもてん真軸上にはない。これを直接ひげ内端点から外端までのひげ全体の重心点計算と、ひげ玉内部に仮想できるいわば切り取られたひげぜんまいの重心点の位置の計算から明確にした。
著者
小牧 昭一郎
出版者
一般社団法人 日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.54, no.202, pp.1-10, 2010
参考文献数
4

The movement of point of gravity of hairspring is so known as the one as far as of it's central area which will cause the vertical positional error at the amplitude 220° in vertical positions, has been once resolved with the famous condition known as the Phillips condition written in 1860 by Edouard Phillips. But it's mathematical formula has not been translated into a helpful form for the actual practice of adjustment of internal curve shape, and has not contributed for the improvement of actual adjustment of vertical positional errors. Then, as the consequence, we have not yet been informed any new researches about this area in these 150 years. Thus the actual method of adjustment of shape of internal curve of hairspring has been long lead with arbitrary ways, almost no method. In this report here is presented the new understanding and the adaptation of the theory above for Archimedes curves used in modem watches. Furthermore here are shown very precise results of adjustment of internal curve of hairspring by following the method in this report. The maximum positional error at 220° amplitude reached to 1.3s/day in case of gentle wrist watches tried here.
著者
久保田 浩司
出版者
一般社団法人日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.49, no.192, pp.53-57, 2005-06-10

2004年は「日本・スイス修好通商条約」140年に当たり, 二つの催しが日本で行われた.その一つはドイツ東洋文化研究教会・在日スイス大使館による10月5日-15日ドイツ文化会館における「エメー・アンベールースイス特派使節の見た幕末日本」展示会開催であり, 二番目は10月9日10時-17時日本女子大学国際交流センターで行われた「幕末・明治期の日瑞交流をめぐって」と題する記念シンポジウムであった.
著者
磯部 浩巳 久曽神 煌
出版者
一般社団法人日本時計学会
雑誌
マイクロメカトロニクス (ISSN:13438565)
巻号頁・発行日
vol.43, no.4, pp.36-46, 1999-12-10

Relative vertical motions between two planes produce load carrying capacity, called squeeze effect. Compressive squeeze air films generated by oscillation of piezoelectric actuators suspend the rotating shaft. Because it requires no air supply, squeeze bearings are applicable to special situation where any air flows in/out have to be avoided. In this study, the active squeeze bearing is proposed, which corrects the motion errors of rotating shaft application of controllable piezo-driving patterns allows the shaft manipulation. In this paper, the air film characteristics are investigated experimentally for a prototype model with two circular plates of 15mm in radius as oscillating pads. The squeeze air film was able to support the object against the external load of 4.9N with a mean film thickness of 5.5μm. It had the capability to support an external load up to 9.8N with a stiffness of 1.8N/μm. By constructing a simple feedback system, the object was manipulated accurately without contact.